A Radiotherapy Treatment Margin Formula When Systematic Positioning Errors are Relatively Small Compared to Random Positioning Errors: A First-Order Approximation
1
作者 kiyoshi yoda 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2017年第2期193-196,共4页
A radiotherapy treatment margin formula has been analytically derived when a standard deviation (SD) of systematic positioning errors &#425;is relatively small compared to an SD of random positioning errors &s... A radiotherapy treatment margin formula has been analytically derived when a standard deviation (SD) of systematic positioning errors &#425;is relatively small compared to an SD of random positioning errors &sigma;. The margin formula for 0 ≤ &#425;≤ &sigma;was calculated by linearly interpolating two boundaries at &#425;= 0 and &#425;= &sigma;, assuming that the van Herk margin approximation of k1&#425;+ k2&sigma;is valid at &#425;= &sigma;. It was shown that a margin formula for 0 ≤ &#425;≤ &sigma;may be approximated by k1&sigma;+ k2&#425;, leading to a more general form of k1 max(&#425;,&sigma;) + k2 min(&#425;,&sigma;) which is a piecewise linear approximation for any values of &#425;and &sigma;. 展开更多
关键词 TREATMENT MARGIN Systematic POSITIONING ERRORS RANDOM POSITIONING ERRORS