期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Heat Transfer and Flow Characteristics of Water Flow with Air Injection in Polyethylene Tube Placed over Metal Rods: Influence of Pitch Length and Tube Width
1
作者 Takuya Kobayashi koji toriyama Shumpei Funatani 《Journal of Flow Control, Measurement & Visualization》 2018年第1期1-14,共14页
A polyethylene tube can be used as a heat exchanger for a low-running-cost?temperature control system. In this system, the flow of temperature-controlled?water in the tube is used as the heat source, and the tube is p... A polyethylene tube can be used as a heat exchanger for a low-running-cost?temperature control system. In this system, the flow of temperature-controlled?water in the tube is used as the heat source, and the tube is placed on the ceiling of a temperature-controlled space using a metal net. Owing to this structure, the tube is deformed by its weight. This deformation has a significant influence on heat transfer and flow characteristics. Therefore, an air injection method, in which air and water are injected simultaneously into the tube, is developed for preventing the deformation of the tube. In this study, bedding metal rods were used instead of a metal net. The influence of the pitch length of the metal rods (5 - 15 cm) and the width of the polyethylene tube 15, 20, 25, 30, and 35 cm was examined experimentally. The length of the polyethylene tube was 178 cm. The air flow rate was 9.5 × 10-5 m3/s. The water flow rates were 60, 80, 100, 120, and 140 mL/min. Results show that the thermal response improved because of air injection. In particular, the temperature at steady state increased, and steady state was attained approximately 1.2 - 3 times faster with air injection than without air injection. The optimum pitch length of the metal rods and the range of the optimum width of the polyethylene tube were 8 cm and 20 - 25 cm, respectively, with and without air injection. 展开更多
关键词 POLYETHYLENE TUBE Air INJECTION Heat Transfer Flow Characteristics Thermal Response
下载PDF
Temperature Measurement of Air Flow Using Fluorescent Mists Combined with Two-Color LIF
2
作者 Shumpei Funatani koji toriyama Tetsuaki Takeda 《Journal of Flow Control, Measurement & Visualization》 2013年第1期20-23,共4页
This study proposes a two-color laser-induced fluorescence (LIF) technique for measuring the temperature distribution of an airflow by spraying a mist of a fluorescent dye. The mist is generated by using propylene gly... This study proposes a two-color laser-induced fluorescence (LIF) technique for measuring the temperature distribution of an airflow by spraying a mist of a fluorescent dye. The mist is generated by using propylene glycol, the vapor pressure of which is much lower than that of water, as the solvent of the fluorescent dyes. A supersonic moisture chamber is used as the atomizer for seeding the tracer particles to be visualized. The proposed technique is applied to the measurement of the temperature distribution in a thermal vertical buoyant plume. The proposed two-color LIF thermometry is found to be very effective for the study of such a thermal structure, and it is well suited for measuring the temperature field of an airflow. 展开更多
关键词 Flow VISUALIZATION Two-Color LIF TEMPERATURE Measurement SPRAYING MIST
下载PDF
Scanning PIV Method and Its Application to the Calorimetry of Ground Source Heat Pump Systems
3
作者 Shumpei Funatani Shinya Amano +1 位作者 Tetsuaki Takeda koji toriyama 《Journal of Flow Control, Measurement & Visualization》 2018年第1期48-55,共8页
Ground source heat pump (GSHP) systems that use a direct expansion method?are expected to have higher energy-saving performance than conventional air conditioning systems. The heat transfer rate is evaluated by measur... Ground source heat pump (GSHP) systems that use a direct expansion method?are expected to have higher energy-saving performance than conventional air conditioning systems. The heat transfer rate is evaluated by measuring the temperature, humidity, and flow rate at the indoor unit of the GSHP system. However, it is difficult to evaluate the flow rate by measuring the flow velocity distribution at the outlet of the indoor unit. In this study, the Scanning PIV method is proposed to improve the accuracy of the flow rate measured by hot wire anemometers. The flow rates obtained by the hot wire anemometers were 60.6% and 15.2% higher than those from the PIV method during cooling and heating operation, respectively. Compensation formulas are generated using the results of the Scanning PIV method to correct the measurements from the hot wire anemometers. This compensation formula reduced the error generated by the nonuniformity of velocity distribution. It was 60.6% to 2.5% in cooling operation and 15.2% to 0.9% in heating operation, respectively. The compensation formulas were applied to evaluate the performance of a GSHP system, and the result shows that the GSHP system provides improved performance stability compared to traditional air conditioning systems. 展开更多
关键词 SCANNING PIV CALORIMETRY GEOTHERMAL HEAT PUMP System
下载PDF
Velocity Measurement by PIV Using W-Shaped Scanning Light Sheet
4
作者 Shumpei Funatani Tetsuaki Takeda koji toriyama 《Journal of Flow Control, Measurement & Visualization》 2015年第1期35-39,共5页
This study proposes a three-dimensional (3D) particle image velocimetry (PIV) method using W- shaped light sheet and color PIV with a digital SLR camera. The uncertainty of the velocity measurement was also studied an... This study proposes a three-dimensional (3D) particle image velocimetry (PIV) method using W- shaped light sheet and color PIV with a digital SLR camera. The uncertainty of the velocity measurement was also studied and it was acceptable. The spatial resolution of the z-direction has much room for improvement by increasing the number of cameras. When applied to the velocity distribution measurement of a thermal vertical buoyant plume, the proposed 3D PIV method is found to be very effective for studying thermal structures and well suited for measuring the airflow velocity field. 展开更多
关键词 3D PIV Color PIV W-Shaped LIGHT SHEET AIRFLOW
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部