As a key part of the diagnosis system in the International Thermonuclear Experimental Reactor(ITER),the neutron flux monitor(NFM),which measures the neutron intensity of the fusion reaction,is a Counting-Campbelling s...As a key part of the diagnosis system in the International Thermonuclear Experimental Reactor(ITER),the neutron flux monitor(NFM),which measures the neutron intensity of the fusion reaction,is a Counting-Campbelling system with a large dynamic counting range.A dynamic linear calibration method is proposed in this paper to solve the problem of cross-over between the different counting and Campbelling channels,and improve the accuracy of the cross-calibration for long-term operation.The experimental results show that the NFM system with the dynamic linear calibration system can obtain the neutron flux of the fusion reactor in real time and realize the seamless measurement area connection between the two channels.展开更多
In order to realize the on-line real-time measurement of neutron spectrum of ITER fusion,this paper presents a multi-sphere spectrometer system which consists of eight thermal neutron detectors,namely SP9 3He proporti...In order to realize the on-line real-time measurement of neutron spectrum of ITER fusion,this paper presents a multi-sphere spectrometer system which consists of eight thermal neutron detectors,namely SP9 3He proportional counter,embedded in eight different diameter polyethylene spheres.The response function of eight polyethylene spheres of multi-sphere neutron spectrometer was calculated after the simulation of the neutron transport processes in multi-sphere spectrometer by adopting software Geant4.The peak of the response function is in the low energy region for smaller diameter polyethylene sphere.As the polyethylene sphere diameter increased,the peak of the response function moves to the high energy region.The experimental calibration adopts 241Am-Be neutron source.The relative error between normalized data of experiment 4πsolid angle counts and normalized data of simulated detection efficiency of 4in to 8in polyethylene sphere is from 1.152%to 12.222%.The experimental results verify the response function of the simulation.All these results provide a theoretical and experimental basis for solving the on-line real-time neutron spectrum of ITER fusion.展开更多
An intelligent control plan for the secondary cooling of continuous casting of slab was put forward. An off-line simulation of the system by using neural networks combined with fuzzy logic control is provided. The res...An intelligent control plan for the secondary cooling of continuous casting of slab was put forward. An off-line simulation of the system by using neural networks combined with fuzzy logic control is provided. The results show that the intelligent control system can not only control the surface temperature of the bloom of the secondary cooling but also has a good ability of self-adaptation and self-learning.展开更多
基金Supported by ITER Plan National Major Project(No.2008GB109000)
文摘As a key part of the diagnosis system in the International Thermonuclear Experimental Reactor(ITER),the neutron flux monitor(NFM),which measures the neutron intensity of the fusion reaction,is a Counting-Campbelling system with a large dynamic counting range.A dynamic linear calibration method is proposed in this paper to solve the problem of cross-over between the different counting and Campbelling channels,and improve the accuracy of the cross-calibration for long-term operation.The experimental results show that the NFM system with the dynamic linear calibration system can obtain the neutron flux of the fusion reactor in real time and realize the seamless measurement area connection between the two channels.
基金Supported by ITER Plan National Major Project 2008GB109000
文摘In order to realize the on-line real-time measurement of neutron spectrum of ITER fusion,this paper presents a multi-sphere spectrometer system which consists of eight thermal neutron detectors,namely SP9 3He proportional counter,embedded in eight different diameter polyethylene spheres.The response function of eight polyethylene spheres of multi-sphere neutron spectrometer was calculated after the simulation of the neutron transport processes in multi-sphere spectrometer by adopting software Geant4.The peak of the response function is in the low energy region for smaller diameter polyethylene sphere.As the polyethylene sphere diameter increased,the peak of the response function moves to the high energy region.The experimental calibration adopts 241Am-Be neutron source.The relative error between normalized data of experiment 4πsolid angle counts and normalized data of simulated detection efficiency of 4in to 8in polyethylene sphere is from 1.152%to 12.222%.The experimental results verify the response function of the simulation.All these results provide a theoretical and experimental basis for solving the on-line real-time neutron spectrum of ITER fusion.
文摘An intelligent control plan for the secondary cooling of continuous casting of slab was put forward. An off-line simulation of the system by using neural networks combined with fuzzy logic control is provided. The results show that the intelligent control system can not only control the surface temperature of the bloom of the secondary cooling but also has a good ability of self-adaptation and self-learning.