期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Optimizing the use of open chambers to measure ammonia volatilization in field plots amended with urea 被引量:1
1
作者 Márcio R.MARTINS leonardo f.sarkis +9 位作者 Selenobaldo A.C.SANT’ANNA Camila A.SANTOS Karla E.ARAUJO Ricardo C.SANTOS Ednaldo S.ARAÚJO Bruno J.R.ALVES Claudia P.JANTALIA Robert M.BODDEY Mohammad ZAMAN Segundo URQUIAGA 《Pedosphere》 SCIE CAS CSCD 2021年第2期243-254,共12页
Measuring ammonia(NH_(3))volatilization from urea-fertilized soils is crucial for evaluation of practices that reduce gaseous nitrogen(N)losses in agriculture.The small area of chambers used for NH_(3)volatilization m... Measuring ammonia(NH_(3))volatilization from urea-fertilized soils is crucial for evaluation of practices that reduce gaseous nitrogen(N)losses in agriculture.The small area of chambers used for NH_(3)volatilization measurements compared with the size of field plots may cause significant errors if inadequate sampling strategies are adopted.Our aims were:i)to investigate the effect of using multiple open chambers on the variability in the measurement of NH_(3)volatilization in urea-amended field plots and ii)to define the critical period of NH_(3)-N losses during which the concentration of sampling effort is capable of reducing uncertainty.The use of only one chamber covering 0.015%of the plot(51.84 m^(2))generates a value of NH_(3)-N loss within an expected margin of error of 30%around the true mean.To reduce the error margin by half(15%),3–7 chambers were required with a mean of 5 chambers per plot.Concentrating the sampling efforts in the first two weeks after urea application,which is usually the most critical period of N losses and associated errors,represents an efficient strategy to lessen uncertainty in the measurements of NH_(3)volatilization.This strategy enhances the power of detection of NH_(3)-N loss abatement in field experiments using chambers. 展开更多
关键词 chamber method experimental error gas emission low-cost chamber nitrogen cycling nitrogen loss soil variability
原文传递
A simple and easy method to measure ammonia volatilization:Accuracy under field conditions
2
作者 Márcio R.MARTINS leonardo f.sarkis +8 位作者 Roni F.GUARESCHI Camila A.SANTOS Selenobaldo A.C.SANT’ANNA Mohammad ZAMAN Claudia P.JANTALIA Bruno J.R.ALVES Robert M.BODDEY Ednaldo S.ARAÚJO Segundo URQUIAGA 《Pedosphere》 SCIE CAS CSCD 2021年第2期255-264,共10页
Field studies on soil ammonia(NH_(3))volatilization are restricted in many countries owing to the high costs commonly demanded for accurate quantification.We assessed the accuracy of a simple,open chamber design to ca... Field studies on soil ammonia(NH_(3))volatilization are restricted in many countries owing to the high costs commonly demanded for accurate quantification.We assessed the accuracy of a simple,open chamber design to capture NH_(3)under field conditions,as affected by different chamber placement schemes.Urea-15 N was surface applied to lysimeters installed in the spaces between maize rows.Open chambers made from plastic bottles were installed on each lysimeter with variations in i)N rates(3,8,13,and 18 g m^(-2)),ii)the height of the chamber above the soil surface(0,5,and 10 mm),and iii)chamber relocation(static vs.dynamic).Reference lysimeters without chambers were used to measure NH_(3)losses by^(15)N-balance.Losses of NH_(3)-N accounted for more than 50%of the applied N.Relocation of the chambers had no impact on their NH_(3)-trapping efficiencies,proving to be an unnecessary procedure.Variation in the height of the chambers above the soil surface affected the capture of NH_(3),but the results still maintained high linearity with the NH_(3)losses quantified by the reference method(R^(2)>0.98).When the same placement scheme used in the introductory study describing the chamber was utilized(static and touching the soil surface),we found a trapping efficiency of 60%,which was very similar to that(57%)obtained in the previous study.Our results show that this simple,open chamber design can be used with satisfactory accuracy under field conditions,provided that simple,standardized procedures are warranted. 展开更多
关键词 ammonia collector chamber method field sampler gas emission low-cost chamber nitrogen cycling
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部