WAXD and SAXS for PA1010+BMI system have been measured. The results obtained with the help of Ruland and ID EDCF. showed that Wc1x1, the long period L and the thickness of the crystal lamellae do decreased with BMI co...WAXD and SAXS for PA1010+BMI system have been measured. The results obtained with the help of Ruland and ID EDCF. showed that Wc1x1, the long period L and the thickness of the crystal lamellae do decreased with BMI content at PA10101+BMI system. Comparing both experimental and calculated densitl c values indicated thst the values were of better conformity. Adding BHI into PA1010 caused an increase in distortion.The results from SAXS analysis have also led to the conclusion that a crystal-amorphous interphase could exist in lamellae of Semicrystalline polymers and a three-phase model instead of traditional two-phase model should be used.展开更多
The structural parameters of the aggregated state under various heat treatment for PA-1010 samples were computed by means of the desmearing intensity from SAXS, and by using the concept of the distance distribution fu...The structural parameters of the aggregated state under various heat treatment for PA-1010 samples were computed by means of the desmearing intensity from SAXS, and by using the concept of the distance distribution function and 1D EDCF method. The results revealed that the maximum values of Q, I(0), Pmax(Z), dtr. Rg and Wcx were obtained nearby T=175℃ for PA-1010 samples with various annealing treatment. The higher degree of the crystallinity, the greater values of all the structural paranleLers of the aggregated state for PA-1010 samples were.展开更多
Synthetic materials that can specifically recognize proteins will find wide application in many fields.In this report,bovine serum albumin was chosen as the template protein.Acrylamide and N,N'-methylenebisacrylamide...Synthetic materials that can specifically recognize proteins will find wide application in many fields.In this report,bovine serum albumin was chosen as the template protein.Acrylamide and N,N'-methylenebisacrylamide were employed as the functional and cross-linker monomers,respectively.Molecularly imprinted macroporous monolithic materials that can preferentially bind the template protein in an aqueous environment were prepared by combination of molecular imprinting technique and freezing/thawing preparation method.The resulted imprinted macroporous monolithic columns were evaluated by utilizing as stationary phase in high performance liquid chromatography and solid-phase extraction materials.The experimental results indicated that the imprinted macroporous monolithic column exhibited good recognition for template protein,as compared with the control protein(hemoglobin),whereas the non-imprinted polymer(prepared under the same conditions except without addition template protein) had no selective properties.展开更多
文摘WAXD and SAXS for PA1010+BMI system have been measured. The results obtained with the help of Ruland and ID EDCF. showed that Wc1x1, the long period L and the thickness of the crystal lamellae do decreased with BMI content at PA10101+BMI system. Comparing both experimental and calculated densitl c values indicated thst the values were of better conformity. Adding BHI into PA1010 caused an increase in distortion.The results from SAXS analysis have also led to the conclusion that a crystal-amorphous interphase could exist in lamellae of Semicrystalline polymers and a three-phase model instead of traditional two-phase model should be used.
文摘The structural parameters of the aggregated state under various heat treatment for PA-1010 samples were computed by means of the desmearing intensity from SAXS, and by using the concept of the distance distribution function and 1D EDCF method. The results revealed that the maximum values of Q, I(0), Pmax(Z), dtr. Rg and Wcx were obtained nearby T=175℃ for PA-1010 samples with various annealing treatment. The higher degree of the crystallinity, the greater values of all the structural paranleLers of the aggregated state for PA-1010 samples were.
基金supported by the National Natural Science Foundation of China(Nos21075089 and 20605024)Talents Fund of Tianjin University of Science and Technology(No20090424)
文摘Synthetic materials that can specifically recognize proteins will find wide application in many fields.In this report,bovine serum albumin was chosen as the template protein.Acrylamide and N,N'-methylenebisacrylamide were employed as the functional and cross-linker monomers,respectively.Molecularly imprinted macroporous monolithic materials that can preferentially bind the template protein in an aqueous environment were prepared by combination of molecular imprinting technique and freezing/thawing preparation method.The resulted imprinted macroporous monolithic columns were evaluated by utilizing as stationary phase in high performance liquid chromatography and solid-phase extraction materials.The experimental results indicated that the imprinted macroporous monolithic column exhibited good recognition for template protein,as compared with the control protein(hemoglobin),whereas the non-imprinted polymer(prepared under the same conditions except without addition template protein) had no selective properties.