With the development of the technology of the Internet of Things,more and more operational data can be collected from air conditioning systems.Unfortunately,the most of existing air conditioning controllers mainly pro...With the development of the technology of the Internet of Things,more and more operational data can be collected from air conditioning systems.Unfortunately,the most of existing air conditioning controllers mainly provide controlling functions more than storing,processing or computing the measured data.This study develops an online fault detection configuration on the equipment side of air conditioning systems to realize these functions.Modbus communication is served to collect real-time operational data.The calculating programs are embedded to identify whether the measured signals exceed their limits or not,and to detect if sensor reading is frozen and other faults in relation to the operational performance are generated or not.The online fault detection configuration is tested on an actual variable-air-volume(VAV)air handling unit(AHU).The results show that the time ratio of fault detection exceeds 95.00%,which means that the configuration exhibits an acceptable fault detection effect.展开更多
LiMn2O4/graphite batteries using LiF additive were fabricated and their electrochemical performance including discharge, cycling and storage performances were tested and compared with LiF-free LiMnEO4/graphite batteri...LiMn2O4/graphite batteries using LiF additive were fabricated and their electrochemical performance including discharge, cycling and storage performances were tested and compared with LiF-free LiMnEO4/graphite batteries. The LiMnEO4/graphite battery with LiF added shows better capacity (107.5 mAh/g), cycling performance (capacity retention ratio of 93% after 100 cycles), and capacity recovery ratio (98.1%) than the LiF-free battery. The improvement in electrochemical performance of the LiF-added LiMnEO4/graphite battery was due to the fact that LiF can restrain the dissolution of Mn from the spinel LiMn2O4 cathode into the electrolyte, leading to a smaller resistance and polariza- tion.展开更多
Experiments have been done on mass transfer to a liquid-liquid interface on which inert gas bubbles are sparged.To simulate the pyrometallurgy system of melten slag-metal(or matte),aqueous solution-mercury(or zinc ama...Experiments have been done on mass transfer to a liquid-liquid interface on which inert gas bubbles are sparged.To simulate the pyrometallurgy system of melten slag-metal(or matte),aqueous solution-mercury(or zinc amalgam) system was used.The mass transfer coefficients of indicator ions as a function of bubble parameters have been determined.The experimental results show satisfactory agreement with the mass transfer model proposed Previously.展开更多
基金Research Project of China Ship Development and Design Center,Wuhan,China。
文摘With the development of the technology of the Internet of Things,more and more operational data can be collected from air conditioning systems.Unfortunately,the most of existing air conditioning controllers mainly provide controlling functions more than storing,processing or computing the measured data.This study develops an online fault detection configuration on the equipment side of air conditioning systems to realize these functions.Modbus communication is served to collect real-time operational data.The calculating programs are embedded to identify whether the measured signals exceed their limits or not,and to detect if sensor reading is frozen and other faults in relation to the operational performance are generated or not.The online fault detection configuration is tested on an actual variable-air-volume(VAV)air handling unit(AHU).The results show that the time ratio of fault detection exceeds 95.00%,which means that the configuration exhibits an acceptable fault detection effect.
基金supported by the Advanced Person Fund of Jiangsu University (No. 10JDG041)the Major State Basic Research Development Program of China(No. 2007CB613607)
文摘LiMn2O4/graphite batteries using LiF additive were fabricated and their electrochemical performance including discharge, cycling and storage performances were tested and compared with LiF-free LiMnEO4/graphite batteries. The LiMnEO4/graphite battery with LiF added shows better capacity (107.5 mAh/g), cycling performance (capacity retention ratio of 93% after 100 cycles), and capacity recovery ratio (98.1%) than the LiF-free battery. The improvement in electrochemical performance of the LiF-added LiMnEO4/graphite battery was due to the fact that LiF can restrain the dissolution of Mn from the spinel LiMn2O4 cathode into the electrolyte, leading to a smaller resistance and polariza- tion.
文摘Experiments have been done on mass transfer to a liquid-liquid interface on which inert gas bubbles are sparged.To simulate the pyrometallurgy system of melten slag-metal(or matte),aqueous solution-mercury(or zinc amalgam) system was used.The mass transfer coefficients of indicator ions as a function of bubble parameters have been determined.The experimental results show satisfactory agreement with the mass transfer model proposed Previously.