期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
SAPT:a synchrotron-based proton therapy facility in Shanghai 被引量:2
1
作者 Man-Zhou Zhang De-Ming Li +45 位作者 li-ren shen Hai-Rong Zhang Zhi-Ling Chen Han-Wen Du Ming Gu Rui Li De-Kang Liu Yue-Hu Pu Jun-Feng Yu Jian-Feng Chen Chu Chen Chun-Long Guo Hao Guo Ge-Yang Jiang Zhi-Qiang Jiang Lin Jin Wen-Jing Li Xiu-Fang Li Ye Lin Ming Liu Yong-Hao Liu Ya-Juan Liu Ming Lv Qing-Ru Mi Lian-Hua Ouyang Wei-Guo Shi Hang Shu Qi-sheng Tang Kun Wang Zhi-Shan Wang Jun Wu Xiao-Bing Wu Jia-Qiang Xu Wen-Zhen Xu Chong-Xian Yin Cheng Yu Ren-Xian Yuan Qi-Bing Yuan Hai-Qun Zhang Miao Zhang Wen-Zhi Zhang Li-Ying Zhao Wei-Min Zhou Shou-Xian Fang Xi-Dong Sun Zhen-Tang Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第10期36-46,共11页
Because of its excellent dose distribution,proton therapy is becoming increasingly popular in the medical application of cancer treatment.A synchrotron-based proton therapy facility was designed and constructed in Sha... Because of its excellent dose distribution,proton therapy is becoming increasingly popular in the medical application of cancer treatment.A synchrotron-based proton therapy facility was designed and constructed in Shanghai.The synchrotron,beam delivery system,and other technical systems were commissioned and reached their expected performances.After a clinical trial of 47 patients was finished,the proton therapy facility obtained a registration certificate from the National Medical Products Administration.The characteristics of the accelerator and treatment systems are described in this article. 展开更多
关键词 Proton therapy SYNCHROTRON Slow extraction GANTRY Beam delivery system
下载PDF
Reformatted method for two-dimensional detector arrays measurement data in proton pencil beam scanning 被引量:2
2
作者 Meng-Ya Guo Xiu-Fang Li +6 位作者 Jie Wang Qi Liu Xiu-Zhen Deng Man-Zhou Zhang li-ren shen Yue-Hu Pu Zhi-Ling Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第6期83-93,共11页
The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with are... The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with areas of steep dose gradients,inter-detector dose values are derived by the interpolation of nearby detector readings in the conventional mathematical interpolation of 2D IC array measurements.This may introduce significant errors,particularly in proton spot scanning radiotherapy.In this study,by combining logfile-based reconstructed dose values and detector measurements with the Laplacian pyramid image blending method,a novel method is proposed to obtain a reformatted dose distribution that provides an improved estimation of the delivered dose distribution with high spatial resolution.Meanwhile,the similarity between the measured original data and the downsampled logfilebased reconstructed dose is regarded as the confidence of the reformatted dose distribution.Furthermore,we quantify the performance benefits of this new approach by directly comparing the reformatted dose distributions with 2D IC array detector mathematically interpolated measurements and original low-resolution measurements.The result shows that this new method is better than the mathematical interpolation and achieves gamma pass rates similar to those of the original low-resolution measurements.The reformatted dose distributions generally yield a confidence exceeding 95%. 展开更多
关键词 2D ion chamber array detectors Laplacian pyramid image blending High-resolution reformatted methods Pencil beam scanning Proton therapy
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部