In certain exceptional cases,capillary samples must be used to measure X-ray absorption spectra(XAS).However,the inho-mogeneous thickness of capillary samples causes XAS distortion.This study discusses the distortion ...In certain exceptional cases,capillary samples must be used to measure X-ray absorption spectra(XAS).However,the inho-mogeneous thickness of capillary samples causes XAS distortion.This study discusses the distortion and correction of the XAS curve caused by the inhomogeneous thickness of capillary samples.The relationship between the distorted XAS curveμ′d_(eq)(measured values)and the real absorption coefficientμ_(s)d_(eq)(true values)of the sample was established.The distortion was slight and negligible when the vertical size(2h)of the X-ray beam spot was smaller than 60%of the capillary tube’s inner diameter(2R_(in)).When h/R_(in)>1,X-ray leakage is inevitable and should be avoided during measurement.Partial X-ray leakage caused by an X-ray beam spot size larger than the inner diameter of the capillary tube leads to serious compressed distortion of the XAS curve.When h/R_(in)<1,the distorted XAS data were well corrected.Possible errors and their influence on the corrected XAS are also discussed.Simulations and corrections for distortions verify the feasibility and effectiveness of the corrected method.展开更多
Experimental techniques based on SR facilities have emerged with the development of synchrotron radiation(SR)sources.Accordingly,detector miniaturization has become significant for the development of SR experimental t...Experimental techniques based on SR facilities have emerged with the development of synchrotron radiation(SR)sources.Accordingly,detector miniaturization has become significant for the development of SR experimental techniques.In this study,the miniaturization of a detector was achieved by coupling a commercial silicon PIN photodiode(SPPD)into a beamstop,aiming for it not only to acquire X-ray absorption fine structure(XAFS)spectra,but also to protect the subsequent two-dimensional detector from high-brilliance X-ray radiation damage in certain combination techniques.This mini SPPD detector coupled to a beamstop was used as the rear detector in both the conventional sampling scheme and novel high-frequency(HF)sampling scheme to collect the transmission XAFS spectra.Traditional ion chambers were also used to collect the transmission XAFS spectra,which were used as the reference.These XAFS spectra were quantitatively analyzed and compared;the results demonstrated that the XAFS spectra collected by this SPPD in both the conventional sampling scheme and HF sampling scheme are feasible.This study provides a new detector-selection scheme for the acquisition of the quick-scanning XAFS(QXAFS)and HF sampling XAFS spectra.The SPPD detector presented in this study can partially meet the requirements of detector miniaturization.展开更多
基金the National Key R&D Program of China(Nos.2022YFA1603802 and 2017YFA0403000)1W2B and 4B9A at the Beijing Synchrotron Radiation Facility.
文摘In certain exceptional cases,capillary samples must be used to measure X-ray absorption spectra(XAS).However,the inho-mogeneous thickness of capillary samples causes XAS distortion.This study discusses the distortion and correction of the XAS curve caused by the inhomogeneous thickness of capillary samples.The relationship between the distorted XAS curveμ′d_(eq)(measured values)and the real absorption coefficientμ_(s)d_(eq)(true values)of the sample was established.The distortion was slight and negligible when the vertical size(2h)of the X-ray beam spot was smaller than 60%of the capillary tube’s inner diameter(2R_(in)).When h/R_(in)>1,X-ray leakage is inevitable and should be avoided during measurement.Partial X-ray leakage caused by an X-ray beam spot size larger than the inner diameter of the capillary tube leads to serious compressed distortion of the XAS curve.When h/R_(in)<1,the distorted XAS data were well corrected.Possible errors and their influence on the corrected XAS are also discussed.Simulations and corrections for distortions verify the feasibility and effectiveness of the corrected method.
基金supported by the National Key R&D Program of China(Nos.2017YFA0403000 and 2017YFA0403100).
文摘Experimental techniques based on SR facilities have emerged with the development of synchrotron radiation(SR)sources.Accordingly,detector miniaturization has become significant for the development of SR experimental techniques.In this study,the miniaturization of a detector was achieved by coupling a commercial silicon PIN photodiode(SPPD)into a beamstop,aiming for it not only to acquire X-ray absorption fine structure(XAFS)spectra,but also to protect the subsequent two-dimensional detector from high-brilliance X-ray radiation damage in certain combination techniques.This mini SPPD detector coupled to a beamstop was used as the rear detector in both the conventional sampling scheme and novel high-frequency(HF)sampling scheme to collect the transmission XAFS spectra.Traditional ion chambers were also used to collect the transmission XAFS spectra,which were used as the reference.These XAFS spectra were quantitatively analyzed and compared;the results demonstrated that the XAFS spectra collected by this SPPD in both the conventional sampling scheme and HF sampling scheme are feasible.This study provides a new detector-selection scheme for the acquisition of the quick-scanning XAFS(QXAFS)and HF sampling XAFS spectra.The SPPD detector presented in this study can partially meet the requirements of detector miniaturization.