期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
value of contrast-enhanced ultrasound in the differential diagnosis of gallbladder lesion 被引量:29
1
作者 Hui-Ping Zhang Min Bai +3 位作者 Ji-Ying Gu Ying-Qian He Xiao-Hui Qiao lian-fang du 《World Journal of Gastroenterology》 SCIE CAS 2018年第6期744-751,共8页
AIM To describe contrast-enhanced ultrasound(CEUS) features and evaluate differential diagnosis value of CEUS and conventional ultrasound for patients with benign and malignant gallbladder lesions. METHODS This study ... AIM To describe contrast-enhanced ultrasound(CEUS) features and evaluate differential diagnosis value of CEUS and conventional ultrasound for patients with benign and malignant gallbladder lesions. METHODS This study included 105 gallbladder lesions. Before surgical resection and pathological examination, conventional ultrasound and CEUS were performed to examine for lesions. Then, all the lesions were diagnosed as(1) benign,(2) probably benign,(3) probably malignant or(4) malignant using both conventional ultrasound and CEUS. The CEUS features of these gallbladder lesions were analyzed and diagnostic efficiency between conventional ultrasound and CEUS was compared.RESULTS There were total 17 cases of gallbladder cancer and 88 cases of benign lesion. Some gallbladder lesions had typical characteristics on CEUS(e.g., gallbladder adenomyomatosis had typical characteristics of small nonenhanced areas on CEUS). The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of CEUS were 94.1%, 95.5%, 80.0%, 98.8%and 95.2%, respectively. These were significantly higher than conventional ultrasound(82.4%, 89.8%, 60.9%, 96.3% and 88.6%, respectively). CEUS had an accuracy of 100% for gallbladder sludge and CEUS helped in differential diagnosis among gallbladder polyps, gallbladder adenoma and gallbladder cancer.CONCLUSION CEUS may provide more useful information and improve the diagnosis efficiency for the diagnosis of gallbladder lesions than conventional ultrasound. 展开更多
关键词 CONTRAST enhanced ULTRASOUND Conventional ULTRASOUND GALLBLADDER carcinoma GALLBLADDER ADENOMYOMATOSIS
下载PDF
Value of shear wave elastography with maximal elasticity in differentiating benign and malignant solid focal liver lesions 被引量:8
2
作者 Hui-Ping Zhang Ji-Ying Gu +3 位作者 Min Bai Fan Li Yu-Qing Zhou lian-fang du 《World Journal of Gastroenterology》 SCIE CAS 2020年第46期7416-7424,共9页
BACKGROUND It is important to differentiate benign and malignant focal liver lesions(FLLs)accurately.Despite the wide use and acceptance of shear wave elastography(SWE),its value for assessing the elasticity of FLLs a... BACKGROUND It is important to differentiate benign and malignant focal liver lesions(FLLs)accurately.Despite the wide use and acceptance of shear wave elastography(SWE),its value for assessing the elasticity of FLLs and differentiating benign and malignant FLLs is still investigational.Previous studies of SWE for FLLs used mean elasticity as the parameter to reflect the stiffness of FLLs.Considering the inhomogeneity of tumor stiffness,maximal elasticity(Emax)might be the suitable parameter to reflect the stiffness of FLLs and to differentiate malignant FLLs from benign ones.AIM To explore the value of SWE with Emax in differential diagnosis of solid FLLs.METHODS We included 104 solid FLLs in 95 patients and 50 healthy volunteers.All the subjects were examined using conventional ultrasound(US)and virtual touch tissue quantification(VTQ)imaging.A diagnosis of benign or malignant FLL was made using conventional US.Ten VTQ values were acquired after 10 consecutive measurements for each FLL and each normal liver,and the largest value was recorded as Emax.RESULTS There were 56 cases of malignant FLLs and 48 cases of benign FLLs in this study.Emax of malignant FLLs(3.29±0.88 m/s)was significantly higher than that of benign FLLs(1.30±0.46 m/s,P<0.01)and that of livers in healthy volunteers(1.15±0.17 m/s,P<0.01).The cut-off point of Emax was 1.945,and the area under the curve was 0.978.The sensitivity and specificity of Emax were 92.9%and 91.7%,respectively,higher(but not significantly)than those of conventional US(80.4%for sensitivity and 81.3%for specificity).Combined diagnosis of conventional US and Emax using parallel testing improved the sensitivity to 100%with specificity of 75%.CONCLUSION SWE is a convenient and easy method to obtain accurate stiffness information of solid FLLs.Emax is useful for differential diagnosis of FLLs,especially in combination with conventional US. 展开更多
关键词 Focal hepatic lesions Shear wave elastography Conventional ultrasound Maximal elasticity
下载PDF
Correlation between blood circulation grading and angiogenesis using ultrasonic contrast of rabbit VX2 hepatic carcinoma 被引量:1
3
作者 Chang-Song Xu Yi-Jin Su +3 位作者 Ming Xu Wei Liu Peng Hao lian-fang du 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2016年第2期148-153,共6页
Objective: To build the rabbit model of VX2 hepatic carcinoma, examine the tumor body using the ultrasonic contrast and study the correlation between the blood circulation grading and angiogenesis. Methods: The VX2 tu... Objective: To build the rabbit model of VX2 hepatic carcinoma, examine the tumor body using the ultrasonic contrast and study the correlation between the blood circulation grading and angiogenesis. Methods: The VX2 tumor strain was prepared in the lateral muscle of the hind legs of 40 male New Zealand rabbits(which were purchased from Nanjing Senbao Biotech Co., Ltd.). The tumor block was embedded in the center of left liver lobe directly to build the rabbit model of VX2 hepatic carcinoma. The ultrasonic contrast was performed 14 d after implanting the tumor body. The semi-quantitative classification(0-Ⅳ level) was taken according to the blood flow of tumor vessel. Animals were executed using the air embolism method. The liver was separated to extract RNA and total protein respectively. The real-time PCR and western blotting method were employed to detect the expression of angiogenesis-related factors of VEGF, b FGF and TNF-γ, while the ultrasonic contrast to detect the correlation with blood circulation grading. The Pearson product moment correlation coefficient was used to measure the linear relationship between these two variables and analyze the correlation between the blood circulation grading and angiogenesis using the ultrasonic contrast. Results: Thirty-three rabbits had the successful model of VX2 hepatic carcinoma. The blood circulation grading by ultrasonic contrast was: 2 cases at level 0(6.60%), 5 cases at level Ⅰ(16.7%), 12 cases at level Ⅱ(40.0%), 6 cases at level Ⅲ(20.0%)(local dense or clustered blood flow) and 5 cases at level Ⅳ(16.7%). The results showed that there was positive correlation between three angiogenesis-related factors and the blood circulation grading. The correlation coefficient between three angiogenesis-related factors and the blood circulation grading was over 0.9, which indicated the relatively high correlation. Conclusions: The ultrasound blood circulation grading for the hepatic carcinoma can clearly reflect the changes of blood vessel, which will be of critical significance for the early diagnosis of hepatic carcinoma and clinical evaluation of angiogenesis indicators. 展开更多
关键词 HEPATIC CARCINOMA VX2 ULTRASONIC CONTRAST ANGIOGENESIS bFGF TNF-α
下载PDF
Gender Differences in Ventricular-vascular Coupling Following Exercise 被引量:1
4
作者 Zhao-jun Li lian-fang du Xiang-hong Luo 《Chinese Medical Sciences Journal》 CAS CSCD 2015年第4期231-238,共8页
Objective To study the differences of cardiovascular system between men and women in response to exercise stress. Methods Forty healthy youth were tested according to Bruce protocol of exercise stress. They were detec... Objective To study the differences of cardiovascular system between men and women in response to exercise stress. Methods Forty healthy youth were tested according to Bruce protocol of exercise stress. They were detected by ultrasonography during the rest, peak exercise, and recovery stages, respectively. The left ventricular diastolic elastance(Ed), effective arterial elastance(Ea), left ventricular end-systolic elatance(Ees), ventricular-vascular coupling index(VVI), and total stiffness index(TSI) were measured and calculated according to the formulas. The results of all stages were compared according to genders. Results All stages, the Ed, TSI, and VVI of women were higher than those of men, but the Ees was lower than that of men(all P<0.05); there was no significant difference in Ea between men and women. The Ed, Ees, Ea, and TSI were closely related with left ventricular oxygen consumption and heart function, and women showed more closely. Before and after exercise, the changes were different in Ed, Ees, Ea, TSI, and VVI(all P<0.05), and VVI changed least. Conclusions Before and after exercise, the ventricular stiffness matched well with arterial stiffness and maintained within a narrow range. For women, the tolerance of exercise was lower than that of men. 展开更多
关键词 ventricular-vascular COUPLING EXERCISE stress GENDER EXERCISE ECHOCARDIOGRAPHY
下载PDF
Ultrasound Assessraent of Intima-media Thickness and Diameter of Carotid Arteries in Patients Undergoing Hemodialysis or Renal Transplantation 被引量:1
5
作者 Zhao-jun Li lian-fang du +2 位作者 Yan QIN Ji-bin LIU Xiang-hong LUO 《Current Medical Science》 SCIE CAS 2018年第4期727-733,共7页
Renal transplant (RT) recipients have a high risk of developing cardiovascular diseases. However, the effects of renal transplantation on the development of arteriosclerosis have been controversial. The carotid inti... Renal transplant (RT) recipients have a high risk of developing cardiovascular diseases. However, the effects of renal transplantation on the development of arteriosclerosis have been controversial. The carotid intima-media thickness (CIMT) and diameter (CD) are important indicators of vascular remodeling and arteriosclerosis. In this study, 31 patients with hemodialysis (HD), 31 RT recipients and 84 age- and gender-matched control subjects were enrolled. Their CIMT and CD were measured by ultrasonic radiofrequency tracking, and the linear regression models and Z test were used to identify the progression of arteriosclerosis and the risk factors. Compared with HD group, RT group had significantly lower CIMT and CD. CIMT was found to be associated with age, body weight, resistance index and diastolic velocity, while CD was associated significantly with age, body weight, pulsatility index, end diastolic velocity and diastolic blood pressure (DBP), respectively. The correlation curves between CIMT and age showed the slopes of curves were decreased successively in control, RT and HD groups, and the curves between CD and age showed the slopes were decreased in order of RT 〉 control 〉 HD groups. It was concluded that CIMT and CD were significantly correlated with age in RT and moderately with age in HD patients. RT could reduce the progress of arteriosclerosis in patients with end-stage renal disease. 展开更多
关键词 ultrasonic radiofrequency tracking renal transplantation ARTERIOSCLEROSIS carotid intima-media thickness age
下载PDF
Contrast-enhanced ultrasound as a valuable imaging modality for characterizing testicular lesions 被引量:1
6
作者 Jie Yu Xin-Hui Jiang +5 位作者 lian-fang du Min Bai Zhao-Jun Li Qiu-Sheng Shi Qi Jiang Fan Li 《Asian Journal of Andrology》 SCIE CAS CSCD 2022年第2期201-206,共6页
Contrast-enhanced ultrasound(CEUS)is a new form of ultrasound(US)that can dynamically display microvessels in a highly sensitive manner.The purpose of this study was to investigate the efficacy of CEUS for characteriz... Contrast-enhanced ultrasound(CEUS)is a new form of ultrasound(US)that can dynamically display microvessels in a highly sensitive manner.The purpose of this study was to investigate the efficacy of CEUS for characterizing testicular lesions in comparison with conventional US.Forty-seven patients with testicular lesions were enrolled.The histopathology results revealed that 31 cases were neoplastic(11 cases of seminomas,8 nonseminomatous germ cell tumors,8 lymphomas,2 Leydig cell tumors,and 2 nonspecific tumors),and 16 cases were nonneoplastic(8 cases of infarctions,3 epidermoid cysts,and 5 inflammation).The indicators of shallow lobulated morphology and cystic-solid echogenicity on conventional US were suggestive of germ cell tumors.More indicators on CEUS were found to be useful for characterizing testicular lesions.All the neoplastic lesions showed hyperenhancement on CEUS.Moreover,germ cell tumors presented with heterogeneous enhancement(73.7%,14/19),a twisted blood vessel pattern,rapid wash-in and wash-out,and peripheral rim hyperenhancement signs.Lymphoma was characterized by nonbranching linear vessel patterns(87.5%,7/8),rapid wash-in and slow wash-out.In nonneoplastic lesions,infarction and epidermoid cysts showed no enhancement,and abscesses were observed with marginal irregular enhancement.The sensitivity,specificity,and accuracy of CEUS for differentiating between neoplastic and nonneoplastic lesions were 100%,93.8%,and 97.9%,respectively,and these values were higher than those for conventional US(90.3%,62.5%,and 80.9%,respectively).CEUS can sensitively reflect the microvascular perfusion in testicular lesions and offers high accuracy for characterizing them. 展开更多
关键词 characterization contrast-enhanced ultrasound DIAGNOSIS testicular neoplasms ULTRASOUND
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部