BACKGROUND Pacemaker lead-induced heart perforation is a rare but life-threatening complication of pacemaker implantation,and timely diagnosis remains a challenge for clinicians.Here,we report a case of pacemaker lead...BACKGROUND Pacemaker lead-induced heart perforation is a rare but life-threatening complication of pacemaker implantation,and timely diagnosis remains a challenge for clinicians.Here,we report a case of pacemaker lead-induced cardiac perforation rapidly diagnosed by a“bow-and-arrow”sign on point-of-care ultrasound(POCUS).CASE SUMMARY A 74-year-old Chinese woman who had undergone permanent pacemaker implantation 26 d before suddenly developed severe dyspnea,chest pain,and hypotension.The patient had received emergency laparotomy for an incarcerated groin hernia and was transferred to the intensive care unit 6 d before.Computed tomography was not available due to unstable hemodynamic status,so POCUS was performed at the bedside and revealed severe pericardial effusion and cardiac tamponade.Subsequent pericardiocentesis yielded a large volume of bloody pericardial fluid.Further POCUS by an ultrasonographist revealed a unique“bow-and-arrow”sign indicating right ventricular(RV)apex perforation by the pacemaker lead,which facilitated the rapid diagnosis of lead perforation.Given the persistent drainage of pericardial bleeding,urgent off-pump open chest surgery was performed to repair the perforation.However,the patient died of shock and multiple organ dysfunction syndrome within 24 h post-surgery.In addition,we also performed a literature review on the sonographic features of RV apex perforation by lead.CONCLUSION POCUS enables the early diagnosis of pacemaker lead perforation at the bedside.A step-wise ultrasonographic approach and the“bow-and-arrow”sign on POCUS are helpful for rapid diagnosis of lead perforation.展开更多
基金Supported by Foundation of Guizhou Science and Technology Department,No.QIANKEHEZHICHEN[2022]YIBAN 179National Natural Science Foundation of China,No.82160370Guizhou Education Department,No.Qian Jiao He KY Zi[2018]239.
文摘BACKGROUND Pacemaker lead-induced heart perforation is a rare but life-threatening complication of pacemaker implantation,and timely diagnosis remains a challenge for clinicians.Here,we report a case of pacemaker lead-induced cardiac perforation rapidly diagnosed by a“bow-and-arrow”sign on point-of-care ultrasound(POCUS).CASE SUMMARY A 74-year-old Chinese woman who had undergone permanent pacemaker implantation 26 d before suddenly developed severe dyspnea,chest pain,and hypotension.The patient had received emergency laparotomy for an incarcerated groin hernia and was transferred to the intensive care unit 6 d before.Computed tomography was not available due to unstable hemodynamic status,so POCUS was performed at the bedside and revealed severe pericardial effusion and cardiac tamponade.Subsequent pericardiocentesis yielded a large volume of bloody pericardial fluid.Further POCUS by an ultrasonographist revealed a unique“bow-and-arrow”sign indicating right ventricular(RV)apex perforation by the pacemaker lead,which facilitated the rapid diagnosis of lead perforation.Given the persistent drainage of pericardial bleeding,urgent off-pump open chest surgery was performed to repair the perforation.However,the patient died of shock and multiple organ dysfunction syndrome within 24 h post-surgery.In addition,we also performed a literature review on the sonographic features of RV apex perforation by lead.CONCLUSION POCUS enables the early diagnosis of pacemaker lead perforation at the bedside.A step-wise ultrasonographic approach and the“bow-and-arrow”sign on POCUS are helpful for rapid diagnosis of lead perforation.