BACKGROUND In atrophic posterior mandibular areas,where the bone height superior to the inferior alveolar nerve(IAN)is less than 6 mm,short implants are not applicable.Conventional alternatives such as IAN transpositi...BACKGROUND In atrophic posterior mandibular areas,where the bone height superior to the inferior alveolar nerve(IAN)is less than 6 mm,short implants are not applicable.Conventional alternatives such as IAN transposition and various alveolar bone augmentation approaches are technically demanding and prone to complications.CASE SUMMARY Computer-guided dynamic navigation implantation improves the accuracy,predictability,and safety of implant placement.This case report presents a dynamic navigation system-guided trans-IAN implant placement technique,which can successfully treat a posterior mandibular dentition defect when the bone height is only 4.5 mm.The implant was inserted into the buccal side of the IAN and was 1.7 mm away from the IAN.The implantation deviations were controlled within a satisfying range,and the long-term restoration outcome was stable.CONCLUSION Dynamic navigation system-guided trans-IAN implant placement might be a recommended technique for patients with extremely insufficient residual bone height and sufficient bone width in the posterior mandibular area.展开更多
The dynamics of granular material discharging from a cuboid but thin hopper,including the hopper flow and granular jet,are investigated via discrete element method(DEM)simulations.The slot width is varied to study its...The dynamics of granular material discharging from a cuboid but thin hopper,including the hopper flow and granular jet,are investigated via discrete element method(DEM)simulations.The slot width is varied to study its influence on the flow.It is found the flow in the cuboid hopper has similarity with the flow in two-dimensional(2D)hopper.When the slot width is large,the flowrate is higher than the predicted value from Beverloo’s law and the velocity distribution is not Gaussian-like.For granular jet,there is a transition with varying slot width.For large slot width,there is a dense core in the jet and the variations of velocities and density are relatively small.Finally,the availability of continuum model is assessed and the results show that the performance with large slot width is better than that with small slot width.展开更多
A parametric study of the clustering transition of a vibration-driven granular gas system is performed by simulation.The parameters studied include the global volume fraction of the system,the size of the system,the f...A parametric study of the clustering transition of a vibration-driven granular gas system is performed by simulation.The parameters studied include the global volume fraction of the system,the size of the system,the friction coefficient,and the restitution coefficient among particles and among particle-walls.The periodic boundary and fixed boundary of sidewalls are also checked in the simulation.The simulation results provide us the necessary“heating”time for the system to reach steady state,and the friction term needed to be included in the“cooling”time.A gas-cluster phase diagram obtained through Kolmogorov-Smirnov(K-S)test analysis using similar experimental parameters is given.The influence of the parameters to the transition is then investigated in simulations.This simulation investigation helps us gain understanding which otherwise cannot be obtained by experiment alone,and makes suggestions on the determination of parameters to be chosen in experiments.展开更多
BACKGROUND Implant fracture is one of the most serious mechanical complications of dental implants.Conventional treatment necessitates visibility of the apical portion of the fractured implant,whereas for deep and inv...BACKGROUND Implant fracture is one of the most serious mechanical complications of dental implants.Conventional treatment necessitates visibility of the apical portion of the fractured implant,whereas for deep and invisible implant fractures,the traditional trephine method has been ineffective.Surgical removal of the marginal bone to expose the fracture surface would be a time-consuming and extensively damaging procedure.Here,we propose a novel technique to address invisible implant fractures.CASE SUMMARY A 50-year-old woman was referred to our department with the chief complaint that her right mandibular implant tooth had fallen out 3 mo earlier.Cone-beam computed tomography examination showed an implant fracture with a fracture surface 5.1 mm below the crestal ridge.The patient was treated with osteotomy combined with the trephine technique to expose the surgical field and remove the implant.The invisible fractured implant was successfully removed,with minimal trauma.A modified Wafer technique-supported guided bone regeneration treatment was then administered to restore the buccal bone wall and preserve the bone mass.Six months later,fine regenerative bone and a wide alveolar crest in the edentulous area were observed,and a new implant was placed.Four months later,restoration was completed using a cemented ceramic prosthesis.Clinical and radiographic examinations 12 mo after loading fulfilled the success criteria.The patient reported no complaints and was satisfied.CONCLUSION Osteotomy combined with the trephine technique can be effectively used to address deep and invisible implant fractures.展开更多
基金Supported by Clinical New Technology and New Business Project (2021)School and Hospital of Stomatology of Wuhan University
文摘BACKGROUND In atrophic posterior mandibular areas,where the bone height superior to the inferior alveolar nerve(IAN)is less than 6 mm,short implants are not applicable.Conventional alternatives such as IAN transposition and various alveolar bone augmentation approaches are technically demanding and prone to complications.CASE SUMMARY Computer-guided dynamic navigation implantation improves the accuracy,predictability,and safety of implant placement.This case report presents a dynamic navigation system-guided trans-IAN implant placement technique,which can successfully treat a posterior mandibular dentition defect when the bone height is only 4.5 mm.The implant was inserted into the buccal side of the IAN and was 1.7 mm away from the IAN.The implantation deviations were controlled within a satisfying range,and the long-term restoration outcome was stable.CONCLUSION Dynamic navigation system-guided trans-IAN implant placement might be a recommended technique for patients with extremely insufficient residual bone height and sufficient bone width in the posterior mandibular area.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11705256 and 11905272)the National Postdoctoral Program for Innovative Talents,China(Grant No.BX201700258)+1 种基金Young Scholar of CAS“Light of West China”Program for Guanghui Yang(Grant No.2018-98)the Strategic Priority Research Program of the Chinese Academy of Sciences(Grant No.XDA21010202)。
文摘The dynamics of granular material discharging from a cuboid but thin hopper,including the hopper flow and granular jet,are investigated via discrete element method(DEM)simulations.The slot width is varied to study its influence on the flow.It is found the flow in the cuboid hopper has similarity with the flow in two-dimensional(2D)hopper.When the slot width is large,the flowrate is higher than the predicted value from Beverloo’s law and the velocity distribution is not Gaussian-like.For granular jet,there is a transition with varying slot width.For large slot width,there is a dense core in the jet and the variations of velocities and density are relatively small.Finally,the availability of continuum model is assessed and the results show that the performance with large slot width is better than that with small slot width.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.U1738120,11474326,and 11705256)Young Scholar of CAS”Light of West China”Program for Guanghui Yang(Grant No.2018-98)+1 种基金the Strategic Priority Research Program of Chinese Academy of Sciences(Grant No.XDA21010202)the International Cooperation Project of China Manned Space Program.
文摘A parametric study of the clustering transition of a vibration-driven granular gas system is performed by simulation.The parameters studied include the global volume fraction of the system,the size of the system,the friction coefficient,and the restitution coefficient among particles and among particle-walls.The periodic boundary and fixed boundary of sidewalls are also checked in the simulation.The simulation results provide us the necessary“heating”time for the system to reach steady state,and the friction term needed to be included in the“cooling”time.A gas-cluster phase diagram obtained through Kolmogorov-Smirnov(K-S)test analysis using similar experimental parameters is given.The influence of the parameters to the transition is then investigated in simulations.This simulation investigation helps us gain understanding which otherwise cannot be obtained by experiment alone,and makes suggestions on the determination of parameters to be chosen in experiments.
文摘BACKGROUND Implant fracture is one of the most serious mechanical complications of dental implants.Conventional treatment necessitates visibility of the apical portion of the fractured implant,whereas for deep and invisible implant fractures,the traditional trephine method has been ineffective.Surgical removal of the marginal bone to expose the fracture surface would be a time-consuming and extensively damaging procedure.Here,we propose a novel technique to address invisible implant fractures.CASE SUMMARY A 50-year-old woman was referred to our department with the chief complaint that her right mandibular implant tooth had fallen out 3 mo earlier.Cone-beam computed tomography examination showed an implant fracture with a fracture surface 5.1 mm below the crestal ridge.The patient was treated with osteotomy combined with the trephine technique to expose the surgical field and remove the implant.The invisible fractured implant was successfully removed,with minimal trauma.A modified Wafer technique-supported guided bone regeneration treatment was then administered to restore the buccal bone wall and preserve the bone mass.Six months later,fine regenerative bone and a wide alveolar crest in the edentulous area were observed,and a new implant was placed.Four months later,restoration was completed using a cemented ceramic prosthesis.Clinical and radiographic examinations 12 mo after loading fulfilled the success criteria.The patient reported no complaints and was satisfied.CONCLUSION Osteotomy combined with the trephine technique can be effectively used to address deep and invisible implant fractures.