期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Thermo-Economic Performance of Geothermal Driven High-Temperature Flash Tank Vapor Injection Heat Pump System:A Comparison Study
1
作者 Huashan Li Xiaoshuang Zhao +2 位作者 Sihao Huang lingbao wang Jiongcong Chen 《Energy Engineering》 EI 2023年第8期1817-1835,共19页
Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is... Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is proposed to develop low-temperature geothermal source for industrial process heating with temperature above 100°C.With heat sink output temperatures between 120°C and 150°C,the thermo-economic performance of the FTVI HTHP system using R1234ze(Z)as refrigerant is analyzed and also compared to the single-stage vapor compression(SSVC)system by employing the developed mathematical model.The coefficient of performance(COP),exergy efficiency(ηexe),net present value(NPV)and payback period(PBP)are used as performance indicators.The results show that under the typical working conditions,the COP andηexe of FTVI HTHP system are 3.00 and 59.66%,respectively,and the corresponding NPV and PBP reach 8.13×106 CNY and 4.13 years,respectively.Under the high-temperature heating conditions,the thermo-economic performance of the FTVI HTHP system is significantly better than that of the SSVC system,and the larger the temperature lift,the greater the thermo-economic advantage of the FTVI HTHP system.Additionally,the FTVI HTHP system is more capable than the SSVC system in absorbing the financial risks associated with changes of electricity price and natural gas price. 展开更多
关键词 Geothermal water high-temperature heat pump flash tank vapor injection thermo-economic performance
下载PDF
Performance Characteristics of Geothermal Single Well for Building Heating
2
作者 Jingying Li Tiejun Zhu +3 位作者 Fengming Li Dong wang Xianbiao Bu lingbao wang 《Energy Engineering》 EI 2021年第3期517-534,共18页
The single well geothermal heating(SWGH)technology has attracted extensive attention.To enhance heat extraction from SWGH,a mathematical model describing heat transfer is set up,and the key influence factor and heat t... The single well geothermal heating(SWGH)technology has attracted extensive attention.To enhance heat extraction from SWGH,a mathematical model describing heat transfer is set up,and the key influence factor and heat transfer enhancement method are discussed by thermal resistance analysis.The numerical results show that the thermal resistance of rock is far greater than that of well wall and fluid.So,reducing rock thermal resistance is the most effective method for enhancing the heat extraction power.For geothermal well planning to drill:rock thermal resistance can be reduced by increasing well diameter and rock thermal conductivity;the temperature difference between liquid and rock can be raised by increasing well depth.For already existing geothermal well:an insulator with thermal conductivity of 0.2 W/(mK)is sufficient to preserve fluid enthalpy;a decrease in injection water temperature causes the increase of heat extraction power from geothermal well and heat output from heat pump simultaneously;increasing injection velocity causes the increase of pump power consumption and heat extraction power from geothermal well as well as net heat output between them.The entrepreneurs may refer to the above data in actual project.Furthermore,filling composite materials with high thermal conductivity into leakage formation is proposed in order to reduce the thermal resistance of rocks. 展开更多
关键词 Geothermal heating heat transfer enhancement single well experiment validation deep borehole heat exchanger thermal resistance
下载PDF
Analysis of Solar Direct-Driven Organic Rankine Cycle Powered Vapor Compression Cooling System Combined with Electric Motor for Office Building Air-Conditioning
3
作者 Xiang Xiao Wei Zhao +4 位作者 Wei wang Wei Zhang Xianbiao Bu lingbao wang Huashan Li 《Energy Engineering》 EI 2021年第1期89-101,共13页
Solar energy powered organic Rankine cycle vapor compression cycle(ORC-VCC)is a good alternative to convert solar heat into a cooling effect.In this study,an ORC-VCC system driven by solar energy combined with electri... Solar energy powered organic Rankine cycle vapor compression cycle(ORC-VCC)is a good alternative to convert solar heat into a cooling effect.In this study,an ORC-VCC system driven by solar energy combined with electric motor is proposed to ensure smooth operation under the conditions that solar radiation is unstable and discontinuous,and an office building located in Guangzhou,China is selected as a case study.The results show that beam solar radiation and generation temperature have considerable effects on the system performance.There is an optimal generation temperature at which the system achieves optimum performance.Also,as a key indicator,the cooling power per square meter collector should be considered in the hybrid solar cooling system in design process.Compared to the vapor compression cooling system,the hybrid cooling system can save almost 68.23%of electricity consumption. 展开更多
关键词 Solar cooling organic Rankine cycle vapor compression cycle hybrid solar cooling system office building air-conditioning
下载PDF
Composite adsorbents of CaCI2 and sawdust prepared by carbonization for ammonia adsorption refrigeration
4
作者 Huashan LI Xianbiao BU +2 位作者 lingbao wang Zhenneng LU Weibin MA 《Frontiers in Energy》 CSCD 2012年第4期356-360,共5页
Composite adsorbents of CaC12 and sawdust prepared by carbonization for adsorption refrigeration with NH3 as refrigerant are tested, and the effects of carboniza tion temperature on the sorption capacity and rate are ... Composite adsorbents of CaC12 and sawdust prepared by carbonization for adsorption refrigeration with NH3 as refrigerant are tested, and the effects of carboniza tion temperature on the sorption capacity and rate are analyzed. The results show that the amount of pores in the sawdust of the composite adsorbents carbonized, apart from the content of CaCI2, is the most dominant factor influencing the NH3 sorption on composite adsorbents. The optimum carbonization temperature is 700℃, which gives the maximal NH3 sorption capacity as high as 0.774 kg of NH3 per kg of the composite, and the specific cooling power is approximately between 338 and 869 W/kg with the cycle duration varying from 5 to 20 minutes. The present study demonstrates that the composite absorbent of CaC12 and sawdust prepared by carbonization is more promising and competitive for adsorption refrigeration application. 展开更多
关键词 Keywords adsorption refrigeration composite adsorbent calcium chloride SAWDUST CARBONIZATION
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部