Objective: To understand distribution and drug resistance of pathogenic bacteria from a specialized cancer hospital in 2013 in order to provide a basis for rational clinical antimicrobial agents. Methods: Pathogenic...Objective: To understand distribution and drug resistance of pathogenic bacteria from a specialized cancer hospital in 2013 in order to provide a basis for rational clinical antimicrobial agents. Methods: Pathogenic bacteria identification and drug sensitivity tests were performed with a VITEK 2 compact automatic identification system and data were analyzed using WHONET5.6 software.Results: Of the 1,378 strains tested, 980 were Gram-negative bacilli, accounting for 71.1%, in which Klebsiella pneumonia, Escherichia coli and Pseudomonas aeruginosa were the dominant strains. We found 328 Gram-positive coccus, accounting for 23.8%, in which the amount of Staphylococcus aureus was the highest. We identified 46 fungi, accounting for 4.1%. According to the departmental distribution within the hospital, the surgical departments isolated the major strains, accounting for 49.7%. According to disease types, lung cancer, intestinal cancer and esophagus cancer were the top three, accounting for 20.9%, 17.3% and 14.2%, respectively. No strains were resistant to imipenem, ertapenem or vancomycin.Conclusions: Pathogenic bacteria isolated from the specialized cancer hospital have different resistance rates compared to commonly used antimicrobial agents; therefore antimicrobial agents to reduce the morbidity and mortality of infections should be used.展开更多
Objective:To study the relationship between plasma treatment time acrylic resin denture material in the size of 2 mm × 10 mm × 10 mm. and efficacy. Methods:Test specimens were prepared from an Plasma treat...Objective:To study the relationship between plasma treatment time acrylic resin denture material in the size of 2 mm × 10 mm × 10 mm. and efficacy. Methods:Test specimens were prepared from an Plasma treatment was carried out on the surface of Polymethyl methacrylate(PMMA) at different time. XPS studies, IR spectra studies and measurement of wetting angle were performed. Results: XPS showed the peak corresponding to C-O getting higher as the treatment proceeded, however at 120 seconds, the peak did not increase any longer and partly crossed with the peak at the duration of 60 seconds. IR spectra showed the wave corresponding to C-H was reduced as O2-plasma treatment proceeded, and then changed little, Wetting angle initially decreased dramatically, however, as the reaction proceeded, wetting angle increased slightly. Conclusion:Equilibrium was reached for introducing oxygen-containing groups and changing of C-H. As the treatment proceeded, wetting angle increased slightly.展开更多
文摘Objective: To understand distribution and drug resistance of pathogenic bacteria from a specialized cancer hospital in 2013 in order to provide a basis for rational clinical antimicrobial agents. Methods: Pathogenic bacteria identification and drug sensitivity tests were performed with a VITEK 2 compact automatic identification system and data were analyzed using WHONET5.6 software.Results: Of the 1,378 strains tested, 980 were Gram-negative bacilli, accounting for 71.1%, in which Klebsiella pneumonia, Escherichia coli and Pseudomonas aeruginosa were the dominant strains. We found 328 Gram-positive coccus, accounting for 23.8%, in which the amount of Staphylococcus aureus was the highest. We identified 46 fungi, accounting for 4.1%. According to the departmental distribution within the hospital, the surgical departments isolated the major strains, accounting for 49.7%. According to disease types, lung cancer, intestinal cancer and esophagus cancer were the top three, accounting for 20.9%, 17.3% and 14.2%, respectively. No strains were resistant to imipenem, ertapenem or vancomycin.Conclusions: Pathogenic bacteria isolated from the specialized cancer hospital have different resistance rates compared to commonly used antimicrobial agents; therefore antimicrobial agents to reduce the morbidity and mortality of infections should be used.
基金This work was supported by Science Fund of Department of Education of Jiangsu Province(06KJD320125)
文摘Objective:To study the relationship between plasma treatment time acrylic resin denture material in the size of 2 mm × 10 mm × 10 mm. and efficacy. Methods:Test specimens were prepared from an Plasma treatment was carried out on the surface of Polymethyl methacrylate(PMMA) at different time. XPS studies, IR spectra studies and measurement of wetting angle were performed. Results: XPS showed the peak corresponding to C-O getting higher as the treatment proceeded, however at 120 seconds, the peak did not increase any longer and partly crossed with the peak at the duration of 60 seconds. IR spectra showed the wave corresponding to C-H was reduced as O2-plasma treatment proceeded, and then changed little, Wetting angle initially decreased dramatically, however, as the reaction proceeded, wetting angle increased slightly. Conclusion:Equilibrium was reached for introducing oxygen-containing groups and changing of C-H. As the treatment proceeded, wetting angle increased slightly.