期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Effects of iodinated contrast on various magnetic resonance imaging sequences and field strength: Implications for characterization of hemorrhagic transformation in acute stroke therapy 被引量:2
1
作者 Humberto Morales lisa lemen +2 位作者 Ranasinghage Samaratunga Peter Nguyen Thomas Tomsick 《World Journal of Radiology》 CAS 2016年第6期588-593,共6页
AIM: To characterize the effects of iodinated contrast material(ICM) on magnetic resonance imaging(MRI) comparing different sequences and magnetic fields, with emphasis to similarities/differences with well-known sign... AIM: To characterize the effects of iodinated contrast material(ICM) on magnetic resonance imaging(MRI) comparing different sequences and magnetic fields, with emphasis to similarities/differences with well-known signal characteristics of hemorrhage in the brain. METHODS: Aliquots of iopamidol and iodixanol mixed with normal saline were scanned at 1.5T and 3T. Signal intensity(SI) was measured using similar spin-echo(SE)-T1, SE-T2, gradient-echo(GRE) and fluid-attenuationinversion-recovery(FLAIR) sequences at both magnets. Contrast to noise ratio(CNR)(SI contrast-SI saline/SD noise) for each aliquot were calculated and Kruskall-wallis test and graphic analysis was used to compare different pulse sequences and ICMs. RESULTS: Both ICM showed increased SI on SE-T1 and decreased SI on SE-T2, GRE and FLAIR at both 1.5T and 3T, as the concentration was increased. By CNR measurements, SE-T2 had the greatest conspicuity at 3T with undiluted iopamidol(92.6 ± 0.3, P < 0.00) followed by iodixanol(77.5 ± 0.9, P < 0.00) as compared with other sequences(CNR range: 15-40). While SE-T2 had greatest conspicuity at 1.5T with iopamidol(49.3 ± 1, P < 0.01), SE-T1 showed similar or slightly better conspicuity(20.8 ± 4) than SE-T2 with iodixanol(23 ± 1.7). In all cases, hypo-intensity on GRE was less conspicuous than on SE-T2.CONCLUSION: Iodixanol and iopamidol shorten T1 and T2 relaxation times at both 1.5T and 3T. Hypo-intensity due to shortened T2 relaxation time is significantly more conspicuous than signal changes on T1-WI, FLAIR or GRE. Variations in signal conspicuity according to pulse sequence and to type of ICM are exaggerated at 3T. We postulate T2 hypointensity with less GRE conspicuity differentiates ICM from hemorrhage; given the wellknown GRE hypointensity of hemorrhage. Described signal changes may be relevant in the setting of recent intra-arterial or intravenous ICM administration in translational research and/or human stroke therapy. 展开更多
关键词 Iodinated CONTRAST Magnetic resonance imaging Gradient-echo HEMORRHAGE STROKE
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部