When a wind turbine is struck by lightning,its blades are usually rotating.The effect of blade rotation on a turbine's ability to trigger a lightning strike is unclear.Therefore,an arching electrode was used in a win...When a wind turbine is struck by lightning,its blades are usually rotating.The effect of blade rotation on a turbine's ability to trigger a lightning strike is unclear.Therefore,an arching electrode was used in a wind turbine lightning discharge test to investigate the difference in lightning triggering ability when blades are rotating and stationary.A negative polarity switching waveform of 250/2500 μs was applied to the arching electrode and the up-and-down method was used to calculate the 50%discharge voltage.Lightning discharge tests of a 1:30 scale wind turbine model with 2,4,and 6 m air gaps were performed and the discharge process was observed.The experimental results demonstrated that when a 2 m air gap was used,the breakdown voltage increased as the blade speed was increased,but when the gap length was 4 m or longer,the trend was reversed and the breakdown voltage decreased.The analysis revealed that the rotation of the blades changes the charge distribution in the blade-tip region,promotes upward leader development on the blade tip,and decreases the breakdown voltage.Thus,the blade rotation of a wind turbine increases its ability to trigger lightning strikes.展开更多
基金supported by the China State Grid Corp headquarters project in 2015(SGTYHT/14JS-188)
文摘When a wind turbine is struck by lightning,its blades are usually rotating.The effect of blade rotation on a turbine's ability to trigger a lightning strike is unclear.Therefore,an arching electrode was used in a wind turbine lightning discharge test to investigate the difference in lightning triggering ability when blades are rotating and stationary.A negative polarity switching waveform of 250/2500 μs was applied to the arching electrode and the up-and-down method was used to calculate the 50%discharge voltage.Lightning discharge tests of a 1:30 scale wind turbine model with 2,4,and 6 m air gaps were performed and the discharge process was observed.The experimental results demonstrated that when a 2 m air gap was used,the breakdown voltage increased as the blade speed was increased,but when the gap length was 4 m or longer,the trend was reversed and the breakdown voltage decreased.The analysis revealed that the rotation of the blades changes the charge distribution in the blade-tip region,promotes upward leader development on the blade tip,and decreases the breakdown voltage.Thus,the blade rotation of a wind turbine increases its ability to trigger lightning strikes.