期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
The Tb Doping Effect on the Room Temperature Magnetoresistance in(La_(1-x)Tb_x)_(0.67)Sr_(0.33)MnO_3(x≤0.4)
1
作者 HongweiQIN JifanHU +3 位作者 JuanCHEN HongdongNIU lumingzhu ZhuoWANG 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2004年第3期350-352,共3页
With substitution of La by Tb in (La_(1-x)Tb_x)_(0.67)Sr_(0.33)MnO_3, the room temperature magnetoresistance △R/R_0drops at first, then undergoes an increase near x≈0.1, and finally drops again. The value of room te... With substitution of La by Tb in (La_(1-x)Tb_x)_(0.67)Sr_(0.33)MnO_3, the room temperature magnetoresistance △R/R_0drops at first, then undergoes an increase near x≈0.1, and finally drops again. The value of room temperaturemagnetoresistance at a field H=12 kOe for (La_(0.9)Tb_(0.1))_(0.67)Sr_(0.33)MnO_3 is -3.56%. The enhancement of the roomtemperature magnetoresistance induced by an appropriate Tb substitution in (La_(1-x)Tb_x)_(0.67)Sr_(0.33)MnO_3 is correlatedwith the shifts of the Curie temperature and metal-insulator temperature to near room temperature. The drop ofthe room temperature magnetoresistance at large Tb doping-contents may be due to its lower T_C and T_(MI) far fromthe room temperature. 展开更多
关键词 MAGNETORESISTANCE (La_(1-x) Tb_x)_(0.67)Sr_(0.33)MnO_3 Curie temperature Metal-insulator temperature
下载PDF
Sub-array patterns of spherical-section phased array for high intensity focused ultrasound surgery
2
作者 WANGXiaodong WANGXufei +1 位作者 lumingzhu WANMingxi 《Chinese Journal of Acoustics》 2005年第1期10-20,共11页
The sub-array field patterns of spherical-section phased array were implemented for noninvasive ultrasound surgery of liver-tumor. The sub-array approach included field calculation, pseudo-inverse method and genetic a... The sub-array field patterns of spherical-section phased array were implemented for noninvasive ultrasound surgery of liver-tumor. The sub-array approach included field calculation, pseudo-inverse method and genetic algorithm. The sub-arrays uncovered by ribs according to scanned images normally emitted ultrasound. The results from different sub-arrays demonstrated quite satisfied acoustic performances, which included qualified focus size and intensity level for ultrasound surgery with single-focus and multi-foci patterns. Moreover, the patterns could decrease power accumulation on the ribs, and avoid damaging normal tissues. Thus the sub-array method provides a promising tool for phased array ultrasound propagating through strong obstacles like human rib cage, and it may broaden the therapeutic area, make the surgery safer and more flexible. 展开更多
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部