Surface electrical resistivity has been used as a tool in the detection of groundwater contamination. In this work, five geoelectric soundings with two at waste dumpsites have been carried out in Uyo, Southwestern Nig...Surface electrical resistivity has been used as a tool in the detection of groundwater contamination. In this work, five geoelectric soundings with two at waste dumpsites have been carried out in Uyo, Southwestern Nigeria to map the gross layered structure of the refuse as well as the extent of groundwater contamination. The geology of the area (Benin Formation) mainly consists of fine-medium-coarse grained sands. The data of five Schlumberger Vertical Electrical Soundings (VES), with a maximum of AB/2=500 m, were analyzed using Hemkler computer program. In general, there exists a common feature in the resistivity variation pattern of high-low-high-low-high in the area. The result shows a wide range of resistivity variation ranging from 2.0 to 60700 ?m. Based on the survey results, the resistivity values less than 75 ?m shows contamination due to waste at Eka street and Udo street. Also, the high resistivity value at mechanic village (60700 ?m) may be related to the waste oil deposit due to the automobile repair activities. A comparison of the resistivity values and the curve types at the dumpsites (Eka street and Udo street) and other locations show that the two dumpsites have an H curve type indicating contaminated zones, while other locations have a K curve type indicating non contaminated zones. Hydrochemical analysis of groundwater samples collected in the area was also carried out for some physico-chemical parameters. The results produced higher concentration of conductivity, total dissolved solids and chloride values for water collected at close locations to dumpsites than those far away from the dumpsites: an evidence for a quantitative assessment of groundwater contamination.展开更多
Although water is a renewable resource for sustaining life and environment, excessive pumping of groundwater results in the ground water table being depleted. The major natural source of groundwater recharge is rainfa...Although water is a renewable resource for sustaining life and environment, excessive pumping of groundwater results in the ground water table being depleted. The major natural source of groundwater recharge is rainfall. In Umudike just like many other areas, the rate of natural recharge is lower than pumping rate. This is due to increasing economic and agricultural activities and also urbanization. Over exploitation of groundwater is a threat to the water quality and table and creates hydrological imbalance. This imbalance includes degradation in hydrological and hydro-chemical characteristics of the aquifer. Artificial recharge of water table aquifers becomes necessary to improve the hydrodynamic conditions of groundwater. A drop in piezometric level can be remedied by artificial recharge of groundwater through infiltration process using water from dams, lakes, rivers, runoff and sewage effluent. Results of water table survey conducted at Umudike show that it peaks at 85m (above sea level) before recharge and 95m after recharge. The recharge of groundwater is basically through rainfall and river water.展开更多
This paper presents the results of seismic compressional, P- and shear, S-wave measurements carried out on the unconsolidated top-soil at the different locations of the study area to determine Poisson’s ratio. In thi...This paper presents the results of seismic compressional, P- and shear, S-wave measurements carried out on the unconsolidated top-soil at the different locations of the study area to determine Poisson’s ratio. In this work, seismic refraction data is used to determine Poisson’s ratio as an aid to engineering foundation. A 12-channel seismograph with signal stacking ability was used together with high frequency (100 Hz) geophones on the top-soil. The geophone intervals were set to 5 m at the all locations. In all the locations, Vp/Vs ratio ranged from 1.0289 to 1.4185 for the top layer. Vp/Vs ratio in the second layer ranged from 1.0512 to 1.5834. The Poisson’s ratio for the first layer ranged from -8.0324 to 0.2060. For the second layer, the Poisson’s ratio ranged from -0.7567 to 0.1683. The values of Vp/Vs ratio less than in the first layer and in some locations in the second layer resulted in negative Poisson’s ratio. The low and negative values of Poisson’s ratio are symptomatic of occurrence of ripable anisotropic materials in the locations where they occur, which suggests that indicated average depth should be removed and refilled with geomaterials that may be resilient to carry engineering loads.展开更多
文摘Surface electrical resistivity has been used as a tool in the detection of groundwater contamination. In this work, five geoelectric soundings with two at waste dumpsites have been carried out in Uyo, Southwestern Nigeria to map the gross layered structure of the refuse as well as the extent of groundwater contamination. The geology of the area (Benin Formation) mainly consists of fine-medium-coarse grained sands. The data of five Schlumberger Vertical Electrical Soundings (VES), with a maximum of AB/2=500 m, were analyzed using Hemkler computer program. In general, there exists a common feature in the resistivity variation pattern of high-low-high-low-high in the area. The result shows a wide range of resistivity variation ranging from 2.0 to 60700 ?m. Based on the survey results, the resistivity values less than 75 ?m shows contamination due to waste at Eka street and Udo street. Also, the high resistivity value at mechanic village (60700 ?m) may be related to the waste oil deposit due to the automobile repair activities. A comparison of the resistivity values and the curve types at the dumpsites (Eka street and Udo street) and other locations show that the two dumpsites have an H curve type indicating contaminated zones, while other locations have a K curve type indicating non contaminated zones. Hydrochemical analysis of groundwater samples collected in the area was also carried out for some physico-chemical parameters. The results produced higher concentration of conductivity, total dissolved solids and chloride values for water collected at close locations to dumpsites than those far away from the dumpsites: an evidence for a quantitative assessment of groundwater contamination.
文摘Although water is a renewable resource for sustaining life and environment, excessive pumping of groundwater results in the ground water table being depleted. The major natural source of groundwater recharge is rainfall. In Umudike just like many other areas, the rate of natural recharge is lower than pumping rate. This is due to increasing economic and agricultural activities and also urbanization. Over exploitation of groundwater is a threat to the water quality and table and creates hydrological imbalance. This imbalance includes degradation in hydrological and hydro-chemical characteristics of the aquifer. Artificial recharge of water table aquifers becomes necessary to improve the hydrodynamic conditions of groundwater. A drop in piezometric level can be remedied by artificial recharge of groundwater through infiltration process using water from dams, lakes, rivers, runoff and sewage effluent. Results of water table survey conducted at Umudike show that it peaks at 85m (above sea level) before recharge and 95m after recharge. The recharge of groundwater is basically through rainfall and river water.
文摘This paper presents the results of seismic compressional, P- and shear, S-wave measurements carried out on the unconsolidated top-soil at the different locations of the study area to determine Poisson’s ratio. In this work, seismic refraction data is used to determine Poisson’s ratio as an aid to engineering foundation. A 12-channel seismograph with signal stacking ability was used together with high frequency (100 Hz) geophones on the top-soil. The geophone intervals were set to 5 m at the all locations. In all the locations, Vp/Vs ratio ranged from 1.0289 to 1.4185 for the top layer. Vp/Vs ratio in the second layer ranged from 1.0512 to 1.5834. The Poisson’s ratio for the first layer ranged from -8.0324 to 0.2060. For the second layer, the Poisson’s ratio ranged from -0.7567 to 0.1683. The values of Vp/Vs ratio less than in the first layer and in some locations in the second layer resulted in negative Poisson’s ratio. The low and negative values of Poisson’s ratio are symptomatic of occurrence of ripable anisotropic materials in the locations where they occur, which suggests that indicated average depth should be removed and refilled with geomaterials that may be resilient to carry engineering loads.