The effect of metal (Ti, Ni, and Au) electrodes on humidity sensing properties of electrospun TiO2 nanofibers was investigated in this work. The devices were fabricated by evaporating metal contacts on SiO2 layer th...The effect of metal (Ti, Ni, and Au) electrodes on humidity sensing properties of electrospun TiO2 nanofibers was investigated in this work. The devices were fabricated by evaporating metal contacts on SiO2 layer thermally grown on silicon substrate. The separation between the electrodes was 90 μm for all sensors. The sensors were tested from 40% to 90% relative humidity (RH) by AC electrical characterization at room temperature. When sensors are switched between 40% and 90% RH, the corresponding response and recovery time are 3 s and 5 s for Ti-electrode sensor, 4 s and 7 s for Ni-electrode sensor, and 7 s and 13 s for Au-electrode sensor. The hysteresis was 3%, 5% and 15% for sensitivity of Ti, Ni, and Au-electrode sensors are Ti-, Ni-, and Au-electrode sensor, respectively. The 7.53 MΩ/%RH, 5.29 MΩ/%RH and 4.01 MΩ/%RH respectively at 100 Hz. Therefore Ti-electrode sensor is found to have linear response, fast response and recovery time and higher sensitivity as compared with those of Ni- and Au-electrode sensors. Comparison of humidity sensing properties of sensors with different electrode material may propose a compelling route for designing and optimizing humidity sensors.展开更多
基金support of the Higher Education Commission(HEC),Pakistan
文摘The effect of metal (Ti, Ni, and Au) electrodes on humidity sensing properties of electrospun TiO2 nanofibers was investigated in this work. The devices were fabricated by evaporating metal contacts on SiO2 layer thermally grown on silicon substrate. The separation between the electrodes was 90 μm for all sensors. The sensors were tested from 40% to 90% relative humidity (RH) by AC electrical characterization at room temperature. When sensors are switched between 40% and 90% RH, the corresponding response and recovery time are 3 s and 5 s for Ti-electrode sensor, 4 s and 7 s for Ni-electrode sensor, and 7 s and 13 s for Au-electrode sensor. The hysteresis was 3%, 5% and 15% for sensitivity of Ti, Ni, and Au-electrode sensors are Ti-, Ni-, and Au-electrode sensor, respectively. The 7.53 MΩ/%RH, 5.29 MΩ/%RH and 4.01 MΩ/%RH respectively at 100 Hz. Therefore Ti-electrode sensor is found to have linear response, fast response and recovery time and higher sensitivity as compared with those of Ni- and Au-electrode sensors. Comparison of humidity sensing properties of sensors with different electrode material may propose a compelling route for designing and optimizing humidity sensors.