期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Evaluation of stress-control layout at the Subtropolis Mine,Petersburg,Ohio 被引量:2
1
作者 Anthony Iannacchione Tim Miller +4 位作者 Gabriel Esterhuizen Brent Slaker michael murphy Natalie Cope Scott Thayer 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2020年第1期77-83,共7页
The Subtropolis room-and-pillar mine extracts the Vanport Limestone(Allegheny Formation,Pennsylvanian System)near Petersburg,Ohio.Strata instability problems associated with excessive concentrations of lateral stress ... The Subtropolis room-and-pillar mine extracts the Vanport Limestone(Allegheny Formation,Pennsylvanian System)near Petersburg,Ohio.Strata instability problems associated with excessive concentrations of lateral stress caused the mine operator to implement a change in layout design.This mining method has been identified as a stress control layout and has been used by other underground stone mines in the past with varying degrees of success.Practical experience has shown that entry headings advance in the direction of the principal lateral stress,producing lower stress concentrations with better mining conditions.It is important to minimize stress concentrations along the mining front,so an arrowshaped advance is recommended.This technique advances more developments(headings)in a"good"direction and reduces developments(crosscuts)in the"bad direction."As is expected,the stress control layout enhances the potential for shear failures in crosscuts.It is,therefore,important to focus crosscut engineering interventions that either:(a)lower stress concentrations(for example,an arched roof)or(b)enhance strength of the strata containing the shears(for example,rock reinforcement).This study focuses on observing strata conditions on a regular basis and monitoring the response of these strata to changing geologic and mining conditions through 3D Dynamic LiDAR scans. 展开更多
关键词 Horizontal STRESS Stress-control LAYOUTS Underground stone mines
下载PDF
美国社区学院和职业教育与培训的关系 被引量:4
2
作者 michael murphy 《职业技术教育》 北大核心 2001年第5期63-64,共2页
美国的社区学院起始于100多年以前.那时候,几所最具声誉的大学领导人,在芝加哥大学校长WILLIAMRAINDY HARPER博士的影响下,开始探索中等与高等教育的衔接问题.他们认为,高等院校最初两年的教育与其后两年的教育相比,实际上与高中最后两... 美国的社区学院起始于100多年以前.那时候,几所最具声誉的大学领导人,在芝加哥大学校长WILLIAMRAINDY HARPER博士的影响下,开始探索中等与高等教育的衔接问题.他们认为,高等院校最初两年的教育与其后两年的教育相比,实际上与高中最后两年的教育更为接近.美国的教育体制包括四年的高中教育和四年的大学本科教育.象芝加哥大学那样的高等院校的办校宗旨是培养他们很多的学生进研究生院.HARPER校长认为,大学教育的重点应着重于本科大学后两年的教育,为学生进研究生院或专职学院作好准备. 展开更多
下载PDF
A Digital Photographic Technique for Knee Range of Motion Measurement: Performance in a Total Knee Arthroplasty Clinical Population
3
作者 michael murphy Julie Hides Trevor Russell 《Open Journal of Orthopedics》 2013年第1期4-9,共6页
Background: Knee range of motion is an essential outcome measure following total knee arthroplasty and it is important to measure this outcome with a simple and accurate tool. Measurement from digital photographs coul... Background: Knee range of motion is an essential outcome measure following total knee arthroplasty and it is important to measure this outcome with a simple and accurate tool. Measurement from digital photographs could provide a superior clinical alternative to the common goniometer as devices for capturing digital photographs are becoming more accessible, measurement accuracy is assisted with the associated software and images can be saved and stored for later reference. This ability to store images with measurements could be particularly useful in research involving knee range of motion. This study evaluated the validity and reliability of a simple photographic measurement technique to measure knee flexion and extension of patients following knee arthroplasty.Methods: Knee flexion and extension of 38 subjects who had undergone total knee arthroplasty were assessed at the one year post-operative review with the digital technique and a universal goniometer as the criterion reference. Digital measurements were repeated one month later by the first assessor (intra-tester reliability) and another independent assessor (inter-tester reliability).Results: Validity: the digital technique was found to have a high level of agreement with the universal goniometer measurements (all MAD sion with almost perfect Intra-Class Correlations (Intra-tester;flexion 0.99, extension 0.96;inter-tester;flexion 0.97, extension 0.93).Conclusion: Measurement of knee range of motion from digital photographs can be used in routine clinical total knee arthroplasty follow-up instead of, or interchangeably with the universal goniometer. 展开更多
关键词 KNEE Range of Motion ARTHROPLASTY DIGITAL Photographic GONIOMETRY
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部