Safety and efficacy of polymer-free paclitaxel-eluting microporous stent in real-world practice: 1-year follow-up of the SERY-I registry 被引量:3
1
作者 Zhang Rui-yan Zhang Qi +26 位作者 Zhu Jin-zhou Chen Liang-long Zhang Chen-yun Zhou Xu-chen Yuan Yong Zhong Zhi-xiong Li Lang Qiu Jian Wang Wei Chen Xi-ming Yang Zhi-jian Yan Jin-chuan Chen Shao-liang Hou Yu-qing Wu Yan-qing Luo Hai-ming Qiu Jian-ping Zhu Li Wang Yan Fu Guo-sheng Wang Jian-an ma kang-hua Yin Yue-hui Zhang Dai-fu Hu Xue-song Zhu Guo-ying Shen Wei-feng 《Chinese Medical Journal》 SCIE CAS CSCD 2011年第21期3521-3526,共6页
Background Polymer coating on coronary stents induces vascular inflammatory response, reduces re-endothelialization, and affects long-term outcome after percutaneous coronary intervention (PCI). The SERY-1 registry ... Background Polymer coating on coronary stents induces vascular inflammatory response, reduces re-endothelialization, and affects long-term outcome after percutaneous coronary intervention (PCI). The SERY-1 registry aimed to determine whether a novel polymer-free paclitaxel-eluting microporous Yinyi stent could improve 1-year outcome after index procedure in real-world clinical practice. Methods Clinical and angiographic data and follow-up outcome were collected in 1045 patients who underwent PCI with implantation of 〉1 Yinyi stents between June 2008 and August 2009 at 27 medical centers. The primary endpoint was the cumulative rate of composite major adverse cardiac events (MACE) and the secondary endpoint was the incidence of stent thrombosis at 1 year. Results Overall, 1376 lesions were treated successfully with 1713 Yinyi stents, and 1019 (98.7%) patients received dual antiplatelet therapy for at least 12 months. During 1-year follow-up, 8 patients (0.78%) had cardiac death, 6 (0.58%) suffered non-fatal myocardial infarction, and 46 (4.46%) underwent repeat PCI due to recurrence of angina, resulting in 1-year MACE-free survival of 94.09%. Stent thrombosis occurred in 10 (0.97%) patients, and the rate of Academic Research Consortium (ARC) definite or probable stent thrombosis was 0.78%. Conclusions Polymer-free paclitaxel-eluting microporous Yinyi stent is effective and safe for interventional treatment of coronary artery disease in real-world clinical practice, without recourse to carrier polymer. Potential long-term clinical advantages of this stent deserve further investigation. 展开更多
关键词 polymer-free microporous stent paclitaxel-eluting stent stent thrombosis
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部