期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Assessment of Rapid Diagnostic Tests Algorithms in Transfusion Medicine Setting
1
作者 Modibo Coulibaly Bakary Maiga +6 位作者 Dramane Samaké Moussa Diawara mahamadou traoré Valentin Sagara Bréhima traoré Oumar Guindo Amagana Dolo 《Advances in Biological Chemistry》 2021年第1期52-63,共12页
<span style="font-family:Verdana;"><strong>Background:</strong></span><span><span><span style="font-family:""><span style="font-family:Verdana... <span style="font-family:Verdana;"><strong>Background:</strong></span><span><span><span style="font-family:""><span style="font-family:Verdana;"> The rapid diagnostic tests play a pivotal role in the screening of viral markers in blood qualification for transfusion in limited resource setting. Therefore, it is important to assess their analytical performances to ensure their proper functioning. </span><b><span style="font-family:Verdana;">Material</span></b> <b><span style="font-family:Verdana;">and</span></b> <b><span style="font-family:Verdana;">Methods:</span></b><span style="font-family:Verdana;"> We performed a cross-</span></span></span></span><span><span><span style="font-family:""> </span></span></span><span><span><span style="font-family:""><span style="font-family:Verdana;">sectional study by successive recruitment to assess the diagnostic value of rapid diagnostic tests algorithms using ELISA as a reference test. A total of 661 blood from donors were enrolled for this study. Rapid Diagnostic Tests (RDTs) and ELISA tests were performed for each sample by a couple of double-blinded biotechnologists. Data were collected on case report form and captured in Microsoft Excel then the file was imported and analyzed using R software version 4.0.3. </span><b><span style="font-family:Verdana;">Results:</span></b><span style="font-family:Verdana;"> The diagnostic accuracy for the algorithms are summarized in </span><b><span style="font-family:Verdana;">Table 1</span></b><span style="font-family:Verdana;">. For HIV-algorithm</span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">,</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> the internal validity parameters were as follow: sensitivity (sens) 99.0% (95% CI = 97.8, 99.5);specificity (spec) 98.3% (95% CI = 90.9, 99.7);positive likelihood ratio (PLR) 57.4 (95% CI = 8.2, 401.0);negative likelihood ratio (NLR) 0.01 (95% CI = 0.0005, 0.02);diagnostic odd ratio (DOR) 4710. HBV-Ag/Ab RDTs achieve the following diagnostic accuracy: sens 99.7% (95% CI = 98.3, 99.9);spec 98.8% (95% CI = 96.9, 95.5);PLR 81.8 (95% CI = 30.9, 217.0);NLR 0.003 (95% CI = 0.0004, 0.02);DOR</span></span></span><span><span><span style="font-family:""> </span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">14</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">,</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">110. The analytical performances of HCV-Ab RDTs were as follow: sens 98.7% (95% CI = 97.5, 99.4);spec 93.1% (95% CI = 78.0, 98.1);PLR 14.3 (95% CI = 3.8, 54.5);NLR 1.5 (95% CI = 0.8, 2.8);DOR 962.6. The parameters evaluating the external validity of RDTs screening for the three viral markers when the theorical prevalence was <</span></span></span><span><span><span style="font-family:""> </span></span></span><span><span><span style="font-family:""><span style="font-family:Verdana;">5% are summarized in </span><b><span style="font-family:Verdana;">Figure </span></b></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><b><span style="font-family:Verdana;">3</span></b></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">. At the prevalence < 5%, the NPV of the three RDTs were 99.96%</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">,</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> 99.99% and 99.94%. At the same prevalence</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">,</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> we found the following Positive Predictive Values (PPV) 70.82%, 77.59% and 37.35% for HIV-Ag/Ab RDTs, HBV-Ag RDTs and HCV-Ab RDTs algorithms, respectively. The overall areas under the received operating characteristic (ROC) curves were 98.6%</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">,</span></span></span><span><span><span style="font-family:""><span style="font-family:Verdana;"> 99.2% and 99.2%;95.9% for HIV-Ag/Ab RDTs, HBV-Ag RDTs and HCV-Ab RDTs algorithms, respectively. </span><b><span style="font-family:Verdana;">Conclusion:</span></b><span style="font-family:Verdana;"> RDTs algorithms can play a pivotal role in the screening of HIV-Ab/Ag, HBs-Ag in the setting of resources limited-countries where financial and technical expertise shortages are a standard fare. However, their use for diagnostic purposes must be done with great caution and the result must necessarily be confirmed with an ELISA or molecular technique particularly for HCV-RDTs algorithm which achieved a</span></span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">n</span></span></span><span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;"> NLR value > 0.1.</span></span></span> 展开更多
关键词 Rapid Diagnostic Tests Analytical Performances ASSESSMENT Transfusion Medicine
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部