This paper presents simulation study on Milled Grooved conformal cooling channels(MGCCC)in injection molding.MGCCC has a more effective cooling surface area which helps to provide efficient cooling as compared to conv...This paper presents simulation study on Milled Grooved conformal cooling channels(MGCCC)in injection molding.MGCCC has a more effective cooling surface area which helps to provide efficient cooling as compared to conventional cooling.A case study of Encloser part is investigated for cycle time reduction and quality improvement.The performance designs of straight drilled are compared with MGCCC by using Autodesk Moldflow Insight(AMI)2016.The results show total 32.1% reduction of cooling time and 9.86% reduction of warpage in case of MGCCC as compared to conventional cooling.展开更多
Cooling system improvement is important in injection molding to get betterquality and productivity. The aim of this paper was to compare the different shapes of theconformal cooling channels (CCC) with constant surfac...Cooling system improvement is important in injection molding to get betterquality and productivity. The aim of this paper was to compare the different shapes of theconformal cooling channels (CCC) with constant surface area and CCC with constantvolume in injection molding using Mold-flow Insight 2016 software. Also the CCC resultswere compared with conventional cooling channels. Four different shapes of the CCC suchas circular, elliptical, rectangular and semi-circular were proposed. The locations of thecooling channels were also kept constant. The results in terms of cooling time, cycle timereduction and improvement in quality of the product shows that no significant effect ofCCC’s shapes when surface area of CCC kept constant. On the other hand, the rectangularCCC shows better result as compared to other shapes of CCC when volume of CCC werekept constant.展开更多
文摘This paper presents simulation study on Milled Grooved conformal cooling channels(MGCCC)in injection molding.MGCCC has a more effective cooling surface area which helps to provide efficient cooling as compared to conventional cooling.A case study of Encloser part is investigated for cycle time reduction and quality improvement.The performance designs of straight drilled are compared with MGCCC by using Autodesk Moldflow Insight(AMI)2016.The results show total 32.1% reduction of cooling time and 9.86% reduction of warpage in case of MGCCC as compared to conventional cooling.
文摘Cooling system improvement is important in injection molding to get betterquality and productivity. The aim of this paper was to compare the different shapes of theconformal cooling channels (CCC) with constant surface area and CCC with constantvolume in injection molding using Mold-flow Insight 2016 software. Also the CCC resultswere compared with conventional cooling channels. Four different shapes of the CCC suchas circular, elliptical, rectangular and semi-circular were proposed. The locations of thecooling channels were also kept constant. The results in terms of cooling time, cycle timereduction and improvement in quality of the product shows that no significant effect ofCCC’s shapes when surface area of CCC kept constant. On the other hand, the rectangularCCC shows better result as compared to other shapes of CCC when volume of CCC werekept constant.