期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Stability Characterization, Kinetics and Mechanism of Degradation of Dantrolene in Aqueous Solution: Effect of pH and Temperature
1
作者 Saeed R. khan Mobin Tawakkul +2 位作者 Vilayat a. Sayeed Patrick Faustino mansoor a. khan 《Pharmacology & Pharmacy》 2012年第3期281-290,共10页
The mechanism of degradation of dantrolene in aqueous buffer solutions was studied at various pH values in the range of pH 1.2-9.5 and at temperatures ranging from 25℃ to 75℃ to determine the optimum pH and temperat... The mechanism of degradation of dantrolene in aqueous buffer solutions was studied at various pH values in the range of pH 1.2-9.5 and at temperatures ranging from 25℃ to 75℃ to determine the optimum pH and temperature requirements for its stability and eventual product performance over the human gastrointestinal pH range. Dantrolene was analyzed by reversed phase ultra-performance liquid chromatographic (UPLC). Chromatographic separation was achieved on a Waters Acquity UPLC system using a Waters BEH C18 analytical column and Waters BEH C18 guard column. The compounds were eluted with a linear acetonitrile gradient (25%-75%) over three minutes with a buffer composition of 2.0 mM of sodium acetate at pH 4.5 for degradation studies. The flow rate was maintained at 0.5 mL/min. Column temperature was maintained at 35℃. Injection volume was 4 μL and the degradation products were detected by a photodiode array (PDA) detector at 375 nm. Degradation products, including compound B and C were analyzed by mass spectroscopy (MS) and nuclear magnetic resonance spectroscopy (NMR) and the degradation pathways were proposed. Degradation of dantrolene followed pseudo first–order kinetics and a V-shaped pH-rate profile over the pH range 1.2-9.5. The maximum stability was observed at pH 7.4 and 37℃. Although the focus of this paper was on the mechanism of hydrolysis of dantrolene, the poor aqueous solubility of dantrolene, the developed understanding can be utilized to improve the quality of the formulation and the risk associated with the extravasation of dantrolene sodium solution in its current form. 展开更多
关键词 DANTROLENE UPLC pH IMPURITY DEGRADATION Compound B C.
下载PDF
Development and Application of a Validated HPLC Method for the Determination of Clindamycin Palmitate Hydrochloride in Marketed Drug Products: An Optimization of the Current USP Methodology for Assay
2
作者 Geoffrey K. Wu abhay Gupta +1 位作者 mansoor a. khan Patrick J. Faustino 《Journal of Analytical Sciences, Methods and Instrumentation》 2013年第4期202-211,共10页
A simple efficient isocratic reversed-phase HPLC method was developed and validated for the determination of clindamycin palmitate hydrochloride (CPH) and its commercially available oral solution products. Separation ... A simple efficient isocratic reversed-phase HPLC method was developed and validated for the determination of clindamycin palmitate hydrochloride (CPH) and its commercially available oral solution products. Separation was achieved on a Phenomenex Zorbax (Luna) cyano column (150 × 4.6 mm, 5 μm) with a Phenomenex cyano guard cartridge (4 × 3.0 mm) on Agilent 1050 series HPLC system. CPH and its resolution standard lincomycin were eluted isocratically at a flow rate of 1 mL/min with a simplified mobile phase (potassium phosphate buffer (5 mM, pH 3.0)—acetonitrile—tetrahydrofuran (20:75:5, v/v/v)) and detected at 210 nm. The column was maintained at 25?C. The method was validated according to USP category I requirements. Robustness and forced degradation studies were also conducted. CPH marketed drug products were obtained from a drug distributor and assayed for potency using the validated method. Validation acceptance criteria were met in all cases. The analytical range for CPH was 15 - 500 μg/mL and the linearity was r2 > 0.999 over three days. The method was determined to be specific and robust. Both accuracy (92.0% - 103.8%) and precision (0.67% - 1.52%) were established across the analytical range for low, intermediate and high QC concentrations. Method applicability was demonstrated by analyzing two marketed products of CPH, in which results showed potency >98%. The method was determined to be an enhancement over the current USP methodology for assay as a result of increased efficiency, reduced organic solvents and the elimination of matrix modifiers. This method was successfully applied for the quality assessment of: 1) currently marketed drug products and 2) will in future assess the product quality of novel dosage forms of CPH for pediatric use. 展开更多
关键词 CLINDAMYCIN PALMITATE HYDROCHLORIDE (CPH) HPLC Method Validation PEDIATRIC DOSAGE Form
下载PDF
A Comparative Evaluation of Polystyrene Divinylbenzene Copolymer HPLC Columns on the Chromatographic Performance of the Compendial Method for Doxycycline Hyclate Capsules: Implications for Method Implementation of a Medical Countermeasure Medication
3
作者 Firat Yerlikaya adil Mohammad +2 位作者 Patrick J. Faustino mansoor a. khan Saeed R. khan 《Journal of Analytical Sciences, Methods and Instrumentation》 2015年第3期23-34,共12页
The purpose of this study was to evaluate the impact of polystyrene divinylbenzene copolymer HPLC columns on the chromatographic performance of the USP compendial method for doxycycline hyclate. The compendial method ... The purpose of this study was to evaluate the impact of polystyrene divinylbenzene copolymer HPLC columns on the chromatographic performance of the USP compendial method for doxycycline hyclate. The compendial method was implemented based on the assessment of the chromatographic performance of six USP defined L21 polystyrene divinylbenzene HPLC columns. Modifications to the method were based on USP for chromatography. The method was validated for the determination of doxycycline hyclate and its impurities in commercially available drug products. A number of different polystyrene-divinylbenzene columns were tested and failed to provide selectivity for the resolution of doxycycline and its impurities. Separation was optimally achieved on an Agilent PLPR-S column (250 × 4.6 mm, 8 μm) by using an Agilent 1260 series HPLC system. Doxycycline hyclate and its impurities were eluted isocratically at a flow rate of 1 mL/min with mobile phase and detected at 270 nm. The column temperature was maintained at 60oC. The method was validated according to USP category I requirements for Assay. Validation acceptance criteria were met in all cases. The analytical range for doxycycline hyclate was 50 - 250 μg/mL and the linearity was r2 > 0.999 over three days. The method was determined to be specific. Both accuracy (95.1% - 102.4%) and precision (0.50% - 4.8%) were established across the analytical range for low, intermediate and high QC concentrations. Method applicability was demonstrated by analyzing marketed products of doxycycline hyclate, in which results showed potency meeting USP acceptance criteria. In conclusion, this study described the remarkable differences in selectivity that were encountered during the implementation phase for the compendial methods for doxycycline and its impurities in marketed products and it could be used in the future to assss the product quality of doxycycline hyclate capsules stored in the National stockpiles. 展开更多
关键词 DOXYCYCLINE 4-Epidoxycycline 6-Epidoxycycline Metacycline POLYSTYRENE-DIVINYLBENZENE
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部