BACKGROUND Orthopedic implant-related infection remains one of the most serious complications after orthopedic surgery.In recent years,there has been an increased scientific interest to improve prevention and treatmen...BACKGROUND Orthopedic implant-related infection remains one of the most serious complications after orthopedic surgery.In recent years,there has been an increased scientific interest to improve prevention and treatment strategies.However,many of these strategies have focused on chemical measures.AIM To analyze the effect of alternating current electrical fields on bacterial adherence to titanium surfaces.METHODS Staphylococcus aureus(S.aureus)and Escherichia coli(E.coli)were exposed to 6.5 V electrical currents at different frequencies:0.5 Hz,0.1 Hz,and 0.05 Hz.After exposure,a bacterial count was then performed and compared to the control model.Other variables registered included the presence of electrocoagulation of the medium,electrode oxidation and/or corrosion,and changes in pH of the medium.RESULTS The most effective electrical model for reducing S.aureus adhesion was 6.5 V alternating current at 0.05 Hz achieving a 90%adhesion reduction rate.For E.coli,the 0.05 Hz frequency model also showed the most effective results with a 53%adhesion reduction rate,although these were significantly lower than S.aureus.Notable adhesion reduction rates were observed for S.aureus and E.coli in the studied conditions.However,the presence of electrode oxidation makes us presume these conditions are not optimal for in vivo use.CONCLUSION Although our findings suggest electrical currents may be useful in preventing bacterial adhesion to metal surfaces,further research using other electrical conditions must be examined to consider their use for in vivo trials.展开更多
基金the DIRECT project (Desarrollo de Nuevos Dispositivos Biomimé ticos Mejorados Superficialmente con Nuevos Recubrimientos y Tratamientos Físicos), which has been funded with a grant from the Centre for Development of Industrial Technology (CDTI)
文摘BACKGROUND Orthopedic implant-related infection remains one of the most serious complications after orthopedic surgery.In recent years,there has been an increased scientific interest to improve prevention and treatment strategies.However,many of these strategies have focused on chemical measures.AIM To analyze the effect of alternating current electrical fields on bacterial adherence to titanium surfaces.METHODS Staphylococcus aureus(S.aureus)and Escherichia coli(E.coli)were exposed to 6.5 V electrical currents at different frequencies:0.5 Hz,0.1 Hz,and 0.05 Hz.After exposure,a bacterial count was then performed and compared to the control model.Other variables registered included the presence of electrocoagulation of the medium,electrode oxidation and/or corrosion,and changes in pH of the medium.RESULTS The most effective electrical model for reducing S.aureus adhesion was 6.5 V alternating current at 0.05 Hz achieving a 90%adhesion reduction rate.For E.coli,the 0.05 Hz frequency model also showed the most effective results with a 53%adhesion reduction rate,although these were significantly lower than S.aureus.Notable adhesion reduction rates were observed for S.aureus and E.coli in the studied conditions.However,the presence of electrode oxidation makes us presume these conditions are not optimal for in vivo use.CONCLUSION Although our findings suggest electrical currents may be useful in preventing bacterial adhesion to metal surfaces,further research using other electrical conditions must be examined to consider their use for in vivo trials.