期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Unreliability of aortic size index to predict risk of aortic dissection in a patient with Turner syndrome 被引量:3
1
作者 Jan Nijs Sandro Gelsomino +3 位作者 Fabiana Lucà Orlando Parise Jos G Maessen mark la meir 《World Journal of Cardiology》 CAS 2014年第5期349-352,共4页
Aortic size index(ASI) has been proposed as a reliable criterion to predict risk for aortic dissection in Turner syndrome with significant thresholds of 20-25 mm/m2. We report a case of aortic arch dissection in a pat... Aortic size index(ASI) has been proposed as a reliable criterion to predict risk for aortic dissection in Turner syndrome with significant thresholds of 20-25 mm/m2. We report a case of aortic arch dissection in a patient with Turner syndrome who, from the ASI thresholds proposed, was deemed to be at low risk of aortic dis-section or rupture and was not eligible for prophylactic surgery. This case report strongly supports careful monitoring and surgical evaluation even when the ASI is < 20 mm/m2 if other significant risk factors are present. 展开更多
关键词 AORTIC DISSECTION AORTIC ANEURYSM TURNER syndrome
下载PDF
心外膜高频刺激心脏植物神经节丛的时间累积和疲劳效应
2
作者 汤敏 mark la meir +1 位作者 陈长志 Jos G Maessen 《中国胸心血管外科临床杂志》 CAS 2009年第5期403-405,共3页
目的观察术中经心外膜对心包内植物神经节丛行高频刺激(HFS)时出现的时间累积效应和疲劳效应,初步探讨其产生的原因和临床意义。方法对江苏昆山宗仁卿纪念医院收治的16例行心脏手术患者同期行同步HFS心脏植物神经节丛,刺激时程从50 ms... 目的观察术中经心外膜对心包内植物神经节丛行高频刺激(HFS)时出现的时间累积效应和疲劳效应,初步探讨其产生的原因和临床意义。方法对江苏昆山宗仁卿纪念医院收治的16例行心脏手术患者同期行同步HFS心脏植物神经节丛,刺激时程从50 ms逐渐延长至100 ms及200 ms,观察P-R间期延长和房室传导阻滞的发生情况。结果16例患者中2例患者被排除,14例患者均在同步HFS时程为50 ms时出现P-R间期延长,100 ms时出现P-R间期进一步延长,200 ms时出现房室传导阻滞的时间累积效应;4例患者发生迷走效应出现后又再次消失的疲劳现象。结论术中经心外膜探查心脏植物神经节丛需重视迷走效应的时间累积和疲劳效应,提高神经节的检出率,并提高心房颤动消融的疗效。 展开更多
关键词 高频刺激 心脏植物神经节丛 时间累积效应 疲劳效应
下载PDF
3D-echo in preoperative assessment of aortic cusps effective height
3
作者 Jan Nijs Sandro Gelsomino +4 位作者 Bastian BLJH Kietselaer Orlando Parise Fabiana Lucà Jos G Maessen mark la meir 《World Journal of Cardiology》 CAS 2014年第7期689-691,共3页
Effective height,which represents the height difference between the central free margins and the aortic insertion lines can be easily determined by 2-D echocardiography and allows for identification of prolapse in the... Effective height,which represents the height difference between the central free margins and the aortic insertion lines can be easily determined by 2-D echocardiography and allows for identification of prolapse in the native cusps and assessment of prolapse correction after valve repair.Nonetheless,it allows to see only two of three aortic valve(AV)coaptation planes and this may lead to misunderstanding of the underlying pathophysiological mechanism for aortic regurgitation and hence in unsuccessful repair.In contrast,3D transoesophageal echocardiography and multiple plane reconstruction lets visualize all the three coaptation planes between the AV cusps and it represents an invaluable tool in the assessment of aortic valve geometry.It is highly recommendable before AV repair to accurately study the complex three dimensional cusps anatomy and their geometric interrelation with aortic root. 展开更多
关键词 AORTIC VALVE AORTIC repair AORTIC PROLAPSE ECHOCARDIOGRAPHY
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部