期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Comment on “A case of hypermature cataract formation following implantation of an implantable collamer lens with an Aquaport”
1
作者 mark packer 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第1期178-178,共1页
Dear Editor,With regard to the recent report published in your journal,"A case of hypermature cataract formationfollowing implantation of an implantable collamer lens with an Aquaport"[1]:the authors suggest... Dear Editor,With regard to the recent report published in your journal,"A case of hypermature cataract formationfollowing implantation of an implantable collamer lens with an Aquaport"[1]:the authors suggest that a case of early onset, rapidly progressive cataract following implantation of a posterior chamber phakic refractive lens with a central port (ICL EVO with KS-Aquaport,STAAR Surgical,Monrovia, CA,USA)was due to rapid or altered flow of aqueous fluid through a decentered Aquaport leading to an inflammatory reaction. 展开更多
关键词 published in your journal progressive CATARACT FOLLOWING IMPLANTATION
下载PDF
Accuracy and safety of partial thickness femtosecond laser radial and arcuate keratotomy incisions in porcine eyes
2
作者 E.Valas Teuma Frank A.Bucci Jr +2 位作者 Raman Bedi Gary Gray mark packer 《Eye and Vision》 SCIE CSCD 2021年第1期412-421,共10页
Background:To evaluate the accuracy and safety of micro radial and arcuate keratotomy incisions constructed by a femtosecond laser system with a curved contact patient interface in porcine eyes.Methods:Partial thickne... Background:To evaluate the accuracy and safety of micro radial and arcuate keratotomy incisions constructed by a femtosecond laser system with a curved contact patient interface in porcine eyes.Methods:Partial thickness micro radial and arcuate keratotomy incisions were constructed in porcine eyes with a femtosecond laser system and evaluated for precision of depth,quality,and consistency.Optical coherence tomography was used to determine the accuracy and precision of incision depth.Corneal endothelial safety was assessed by a fluorescent live/dead cell viability assay to demonstrate laser-induced endothelial cell loss.Quality was evaluated by ease of opening and examination of interfaces.Results:In two micro radial incision groups,intended incision depths of 50%and 80%resulted in mean achieved depths of 50.01%and 77.69%,respectively.In three arcuate incision groups,intended incision depths of 80%,600μm or 100μm residual uncut bed thickness resulted in mean achieved depths of 80.16%,603.03μm and residual bed of 115μm,respectively.No loss of endothelial cell density occurred when the residual corneal bed was maintained at a minimum of 85-116μm.The incisions were easy to open,and interfaces were smooth.Conclusions:A femtosecond laser system with curved contact interface created precise and reproducible micro radial and arcuate keratotomy incisions.Accuracy and precision of the incision depth and preservation of endothelial cell density demonstrated the effectiveness and safety of the system. 展开更多
关键词 Partial thickness micro radial and arcuate keratotomy incisions Curved contact patient interface Micro radial keratotomy Arcuate keratotomy Femtosecond laser system with curved contact interface LENSAR femtosecond laser system
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部