We reviewed the literature on transcutaneous electrical nerve stimulation(TENS)used as a therapy for overactive bladder(OAB)symptoms,with a particular focus on:stimulation site,stimuli parameters,neural structures tho...We reviewed the literature on transcutaneous electrical nerve stimulation(TENS)used as a therapy for overactive bladder(OAB)symptoms,with a particular focus on:stimulation site,stimuli parameters,neural structures thought to be targeted,and the clinical and urodynamic outcomes achieved.The majority of studies used sacral or tibial nerve stimulation.The literature suggests that,whilst TENS therapy may have neuromodulation effects,patient are unlikely to benefit to a significant extent from a single application of TENS and indeed clear benefits from acute studies have not been reported.In long-term studies there were differences in the descriptions of stimulation intensity,strategy of the therapy,and positioning of the electrodes,as well as in the various symptoms and pathology of the patients.Additionally,most studies were uncontrolled and hence did not evaluate the placebo effect.Little is known about the underlying mechanism by which these therapies work and therefore exactly which structures need to be stimulated,and with what parameters.There is promising evidence for the efficacy of a transcutaneous stimulation approach,but adequate standardisation of stimulation criteria and outcome measures will be necessary to define the best way to administer this therapy and document its efficacy.展开更多
<strong>Purpose:</strong> To clinically evaluate a new extended depth of focus intraocular lens (ISOPURE, PhysIOL) with optic design modification based on a unique polynomial concept to improve intermediat...<strong>Purpose:</strong> To clinically evaluate a new extended depth of focus intraocular lens (ISOPURE, PhysIOL) with optic design modification based on a unique polynomial concept to improve intermediate vision while keeping the quality of distance vision equal to a monofocal lens. <strong>Methods:</strong> 18 patients (11 female, 7 male, mean age of 69.4 years) with bilateral cataract and regular corneal astigmatism ≤ 1.0 D underwent bilateral cataract surgery with ISOPURE implantation. Patients were followed for up to 6 months. Measured parameters were uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity at 80 cm and 66 cm (DCI80VA, DCI66VA) subjective refraction, defocus curve, tolerance of cylinder induction, and contrast sensitivity. The data from all implanted eyes (all-eyes) and a subset only including the first eye implanted for each patient were analysed. <strong>Results:</strong> The mean manifest refraction spherical equivalent (MRSE) decreased from 1.05 D pre-operatively to ?0.15 D at the 4 - 6 month assessment, with 80.6% of eyes within ±0.50 D of emmetropia. At the final follow-up, mean (SD) monocular CDVA was ?0.06 (0.04) logMAR, DCI80VA was 0.18 (0.08) logMAR and DCI66VA was 0.27 (0.13) logMAR. Despite a cylinder induction of ?0.50 D, uncorrected distance visual acuity of 0.02 logMAR was still achieved. <strong>Conclusion:</strong> The ISOPURE intraocular lens provides excellent distance corrected visual acuity for far and intermediate distances along with high contrast sensitivity and good tolerance of residual refractive cylinder.展开更多
基金funded by the European Commission’s Research and Innovation Framework programme(Marie Curie Actions Initial Training Network)for the TRUST project(Training Urology Scientists to Develop Treatments)Grant Number 238541The study formed part of the project portfolio of the NIHR Devices for Dignity Healthcare Technology Cooperative.
文摘We reviewed the literature on transcutaneous electrical nerve stimulation(TENS)used as a therapy for overactive bladder(OAB)symptoms,with a particular focus on:stimulation site,stimuli parameters,neural structures thought to be targeted,and the clinical and urodynamic outcomes achieved.The majority of studies used sacral or tibial nerve stimulation.The literature suggests that,whilst TENS therapy may have neuromodulation effects,patient are unlikely to benefit to a significant extent from a single application of TENS and indeed clear benefits from acute studies have not been reported.In long-term studies there were differences in the descriptions of stimulation intensity,strategy of the therapy,and positioning of the electrodes,as well as in the various symptoms and pathology of the patients.Additionally,most studies were uncontrolled and hence did not evaluate the placebo effect.Little is known about the underlying mechanism by which these therapies work and therefore exactly which structures need to be stimulated,and with what parameters.There is promising evidence for the efficacy of a transcutaneous stimulation approach,but adequate standardisation of stimulation criteria and outcome measures will be necessary to define the best way to administer this therapy and document its efficacy.
文摘<strong>Purpose:</strong> To clinically evaluate a new extended depth of focus intraocular lens (ISOPURE, PhysIOL) with optic design modification based on a unique polynomial concept to improve intermediate vision while keeping the quality of distance vision equal to a monofocal lens. <strong>Methods:</strong> 18 patients (11 female, 7 male, mean age of 69.4 years) with bilateral cataract and regular corneal astigmatism ≤ 1.0 D underwent bilateral cataract surgery with ISOPURE implantation. Patients were followed for up to 6 months. Measured parameters were uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity at 80 cm and 66 cm (DCI80VA, DCI66VA) subjective refraction, defocus curve, tolerance of cylinder induction, and contrast sensitivity. The data from all implanted eyes (all-eyes) and a subset only including the first eye implanted for each patient were analysed. <strong>Results:</strong> The mean manifest refraction spherical equivalent (MRSE) decreased from 1.05 D pre-operatively to ?0.15 D at the 4 - 6 month assessment, with 80.6% of eyes within ±0.50 D of emmetropia. At the final follow-up, mean (SD) monocular CDVA was ?0.06 (0.04) logMAR, DCI80VA was 0.18 (0.08) logMAR and DCI66VA was 0.27 (0.13) logMAR. Despite a cylinder induction of ?0.50 D, uncorrected distance visual acuity of 0.02 logMAR was still achieved. <strong>Conclusion:</strong> The ISOPURE intraocular lens provides excellent distance corrected visual acuity for far and intermediate distances along with high contrast sensitivity and good tolerance of residual refractive cylinder.