期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
2D and 3D refraction-based visualization of breast cancer for early clinical check 被引量:2
1
作者 masami ando Anton MAKSIMENKO +9 位作者 Tetsuya YUASA Eiko HASHIMOTO Katsuhito YAMASAKI Shu IHIHARA Hiroshi SUGIYAMA Tokiko ENDO LI Gang CHEN Zhihua Kazuyuki HYODO Ei UENO 《Nuclear Science and Techniques》 SCIE CAS CSCD 2006年第6期389-395,共7页
Ductal carcinoma in-situ (DCIS) has been visualized by 2D XDFI (X-ray dark-field imaging) and further by a 3D X-ray CT, and the data was acquired by the X-ray optics DEI (diffraction-enhanced imaging). A newly made al... Ductal carcinoma in-situ (DCIS) has been visualized by 2D XDFI (X-ray dark-field imaging) and further by a 3D X-ray CT, and the data was acquired by the X-ray optics DEI (diffraction-enhanced imaging). A newly made algorithm was used for CT. Data of 900 projections with interval of 0.2 degrees were used. Ductus lactiferi, microcalci-fication in a 3D form have been clearly visible. The spatial resolution available was approximately 30μm. 展开更多
关键词 折射 乳腺癌 临床检查 CT
下载PDF
Small Angle X-Ray Scattering Imaging of Soft Tissue by Using Laue Diffraction Optical System
2
作者 Ge Jin Kenichi Okamura +3 位作者 Yoshifumi Suzuki Yong Sun Yoshinori Chikaura masami ando 《Open Journal of Medical Imaging》 2018年第3期54-63,共10页
We performed a feasibility study of Small angle X-ray scattering imaging under the condition of X-ray bright field imaging by Laue crystal diffraction optics of X-ray dark-field imaging that works as an angular analys... We performed a feasibility study of Small angle X-ray scattering imaging under the condition of X-ray bright field imaging by Laue crystal diffraction optics of X-ray dark-field imaging that works as an angular analysis. Collagen in chicken tibia containing abundant soft fibrous tissue was chosen as a specimen. In traditional Small angle X-ray scattering optical system, we can derive the structure information of sample by calculating q value which is available from a scattering pattern. Thus it is usually necessary to conduct a 2D scan in order to obtain scattering image. In this paper it is described by a method by which not only small angle X-ray scattering imaging is available directly but also bright-field imaging and dark-field imaging can be obtained at the same time. As the first step, the feasibility of the imaging method should be confirmed by taking pictures of the samples with known periodic length. The preliminary test showed that the collgan’s lattice spacing d is 65.1 nm that was also taken photos by scanning electron microscopy. By rotating Laue angular analyzer by 112 arcseconds small angle X-ray scattering image appeared in bright-field. 展开更多
关键词 XDFI SAXS SYNCHROTRON RADIATION SOFT TISSUE
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部