期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
整形外科用摩擦焊纯钛/镁合金螺钉的力学性能、腐蚀行为和生物相容性 被引量:8
1
作者 Mojtaba Sadeghi GOGHERI masoud kasiri-asgarani +2 位作者 Hamid Reza BAKHSHESHI-RAD Hamid GHAYOUR Mahdi RAFIEI 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2020年第11期2952-2966,共15页
在转速为1100、1200和1300 r/min条件下,通过旋转摩擦焊将生物可降解镁合金与商业纯钛异种焊接后加工成螺钉,研究异种接头的性能。金相分析结果表明钛/镁合金接头处连接较好。在镁合金一侧观察到焊缝中心区(WCZ)、动态再结晶区(DRX)、... 在转速为1100、1200和1300 r/min条件下,通过旋转摩擦焊将生物可降解镁合金与商业纯钛异种焊接后加工成螺钉,研究异种接头的性能。金相分析结果表明钛/镁合金接头处连接较好。在镁合金一侧观察到焊缝中心区(WCZ)、动态再结晶区(DRX)、热力影响区(TMAZ)和局部变形区(PDZ)。在1300 r/min转速下制备的螺钉具有最高的拉伸强度和剪切强度,分别为173和103.2 MPa。钛/镁合金异种摩擦焊接头在含有Ti3Al的金属间化合物区附近失效。由于晶粒细化(8.57μm)和钛颗粒的影响,从镁合金一侧到焊缝区,硬度值逐渐增大;而钛一侧的硬度值保持不变。浸泡实验显示钛/镁合金接头的腐蚀速率高于纯钛与镁合金的腐蚀速率。此外,1300 r/min转速下制备的接头由于其更好的耐腐蚀性能,显示出更好的生物相容性和细胞活性(98.12%)。 展开更多
关键词 镁合金 商业纯钛 摩擦焊 剪切强度 生物降解性
下载PDF
中间层成分对GTD-111/IN-718高温合金在瞬时液相连接过程中显微组织和力学性能的影响 被引量:2
2
作者 Ali IZADI GHAHFEROKHI masoud kasiri-asgarani +2 位作者 Kamran AMINI Mahdi RAFIEI Reza EBRAHIMI-KAHRIZSANGI 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2022年第3期908-926,共19页
研究使用不同的中间层瞬时液相连接两种异种高温合金的适用性。在1100℃、不同时间下瞬时液相连接GTD-111/IN-718体系,研究BNi-2、BNi-3和BNi-9三种类型的中间层对该体系显微组织和力学性能的影响。采用场发射扫描电子显微镜和能量色散... 研究使用不同的中间层瞬时液相连接两种异种高温合金的适用性。在1100℃、不同时间下瞬时液相连接GTD-111/IN-718体系,研究BNi-2、BNi-3和BNi-9三种类型的中间层对该体系显微组织和力学性能的影响。采用场发射扫描电子显微镜和能量色散光谱技术,研究接头区域的成分变化和显微组织。结果表明,非热凝固区Ni_(3)B的形成受B含量控制,相应地,Ni_(3)Si的形貌受Si含量控制。Cr含量可能会阻碍B从中间层向母材迁移,非热凝固区内Cr B的形成主要受Cr含量的影响。硼化物如镍或铬硼化物基体的形成,使共晶化合物具有高的显微硬度。与使用BNi-3和BNi-2中间层的合金接头相比,等温凝固结束后,使用BNi-9中间层的合金接头其剪切强度更低,这可能与金属焊料成分中不含Si和BNi-9中含Cr有关。 展开更多
关键词 瞬时液相连接 镍基高温合金 等温凝固 Ni-B化合物
下载PDF
In vitro bioactivity and corrosion of PLGA/hardystonite composite-coated magnesium-based nanocomposite for implant applications 被引量:1
3
作者 Mahmood Razzaghi masoud kasiri-asgarani +1 位作者 Hamid Reza Bakhsheshi-Rad Hamid Ghayour 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2021年第1期168-178,共11页
A type of polymer/ceramic coating was introduced on a magnesium-based nanocomposite, and the nanocomposite was evaluated for implant applications.The microstructure, corrosion, and bioactivity of the coated and uncoat... A type of polymer/ceramic coating was introduced on a magnesium-based nanocomposite, and the nanocomposite was evaluated for implant applications.The microstructure, corrosion, and bioactivity of the coated and uncoated samples were assessed.Mechanical alloying followed by sintering was applied to fabricate the Mg–3Zn–0.5Ag–15NiTi nanocomposite substrate.Moreover, different contents of poly(lactic-co-glycolic acid)(PLGA) coatings were studied, and 10 wt% of PLGA content was selected.The scanning electron microscopy(SEM) images of the bulk nanocomposite showed an acceptable homogenous dispersion of the Ni Ti nanoparticles(NPs) in the Mg-based matrix.In the in vitro bioactivity evaluation, following the immersion of the uncoated and coated samples in a simulated body fluid(SBF) solution, the Ca/P atomic ratio demonstrated that the apatite formation amount on the coated sample was greater than that on the uncoated nanocomposite.Furthermore, assessing the corrosion resistance indicated that the coatings on the Mg-based substrate led to a corrosion current density(icorr) that was considerably lower than that of the substrate.Such a condition revealed that the coating would provide an obstacle for the corrosion.Based on this study, the PLGA/hardystonite(HT) composite-coated Mg–3Zn–0.5Ag–15NiTi nanocomposite may be suitably applied as an orthopedic implant biomaterial. 展开更多
关键词 MAGNESIUM NANOCOMPOSITE CORROSION BIOCOMPATIBILITY poly(lactic-co-glycolic acid) hardystonite
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部