期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Combination of Model-based Observer and Support Vector Machines for Fault Detection of Wind Turbines 被引量:11
1
作者 Nassim Laouti Sami Othman +1 位作者 mazen alamir Nida Sheibat-Othman 《International Journal of Automation and computing》 EI CSCD 2014年第3期274-287,共14页
Support vector machines and a Kalman-like observer are used for fault detection and isolation in a variable speed horizontalaxis wind turbine composed of three blades and a full converter. The support vector approach ... Support vector machines and a Kalman-like observer are used for fault detection and isolation in a variable speed horizontalaxis wind turbine composed of three blades and a full converter. The support vector approach is data-based and is therefore robust to process knowledge. It is based on structural risk minimization which enhances generalization even with small training data set and it allows for process nonlinearity by using flexible kernels. In this work, a radial basis function is used as the kernel. Different parts of the process are investigated including actuators and sensors faults. With duplicated sensors, sensor faults in blade pitch positions,generator and rotor speeds can be detected. Faults of type stuck measurements can be detected in 2 sampling periods. The detection time of offset/scaled measurements depends on the severity of the fault and on the process dynamics when the fault occurs. The converter torque actuator fault can be detected within 2 sampling periods. Faults in the actuators of the pitch systems represents a higher difficulty for fault detection which is due to the fact that such faults only affect the transitory state(which is very fast) but not the final stationary state. Therefore, two methods are considered and compared for fault detection and isolation of this fault: support vector machines and a Kalman-like observer. Advantages and disadvantages of each method are discussed. On one hand, support vector machines training of transitory states would require a big amount of data in different situations, but the fault detection and isolation results are robust to variations in the input/operating point. On the other hand, the observer is model-based, and therefore does not require training, and it allows identification of the fault level, which is interesting for fault reconfiguration. But the observability of the system is ensured under specific conditions, related to the dynamics of the inputs and outputs. The whole fault detection and isolation scheme is evaluated using a wind turbine benchmark with a real sequence of wind speed. 展开更多
关键词 Fault detection and isolation wind turbine Kalman-like observer support vector machines data-based classification
原文传递
Experimental investigation of control updating period monitoring in industrial PLC-based fast MPC: Application to the constrained control of a cryogenic refrigerator 被引量:1
2
作者 Francois BONNE mazen alamir Patrick BONNAY 《Control Theory and Technology》 EI CSCD 2017年第2期92-108,共17页
In this paper, a complete industrial validation of a recently published scheme for on-line adaptation of the control updating period in model predictive control is proposed. The industrial process that serves in the v... In this paper, a complete industrial validation of a recently published scheme for on-line adaptation of the control updating period in model predictive control is proposed. The industrial process that serves in the validation is a cryogenic refrigerator that is used to cool the supra-conductors involved in particle accelerators or experimental nuclear reactors. Two recently predicted features are validated: the first states that it is sometimes better to use less efficient (per iteration) optimizer if the lack of efficiency is overmcompensated by an increase in the updating control frequency. The second is that for a given solver, it is worth monitoring the control updating period based on the on-line measured behavior of the cost function. 展开更多
关键词 Fast MPC cryogenic refrigerators control updating period ODE-based optimization
原文传递
A phase-locked loop using ESO-based loop filter for grid-connected converter: performance analysis
3
作者 Baoling Guo Seddik Bacha +1 位作者 mazen alamir Julien Pouget 《Control Theory and Technology》 EI CSCD 2021年第1期49-63,共15页
An extended state observer(ESO)-based loop filter is designed for the phase-locked loop(PLL)involved in a disturbed grid-connected converter(GeC).This ESO-based design enhances the performances and robustness of the P... An extended state observer(ESO)-based loop filter is designed for the phase-locked loop(PLL)involved in a disturbed grid-connected converter(GeC).This ESO-based design enhances the performances and robustness of the PLL,and,therefore,improves control performances of the disturbed GeCs.Besides,the ESO-based LF can be applied to PLLs with extra filters for abnormal grid conditions.The unbalanced grid is particularly taken into account for the performance analysis.A tuning approach based on the well-designed PI controller is discussed,which results in a fair comparison with conventional PI-type PLLs.The frequency domain properies are quantitatively analysed with respeet to the control stability and the noises rejection.The frequency domain analysis and simulation results suggesti that the performances of the generated ESO-based controllers are comparable to those of the PI control at low frequency,while have better ability to atenuate high-frequency measurement noises.The phase margin decreases slightly,but remains acceptable.Finally,experimental tests are conducted with a hybrid power hardwarein-the-loop benchmark,in which balanced/unbalanced cases are both explored.The obtained results prove the effectiveness of ESO based PLLs when applied to the disturbed GeC. 展开更多
关键词 Grid-conected converters Grid disturbances Phase-locked loop Loop filter Extended state observer Tuning approach Stability analysis Phase margin Noises attenuation Power hardware-in-the-loop(PHIL)test
原文传递
上一页 1 下一页 到第