期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Micro-Scanning Error Correction Technique for an Optical Micro-Scanning Thermal Microscope Imaging System
1
作者 meijing gao Ying Han +3 位作者 Qiushi Geng Yong Zhao Bozhi Zhang Liuzhu Wang 《Journal of Beijing Institute of Technology》 EI CAS 2019年第3期510-518,共9页
An error correction technique for the micro-scanning instrument of the optical micro-scanning thermal microscope imaging system is proposed. The technique is based on micro-scanning technology combined with the propos... An error correction technique for the micro-scanning instrument of the optical micro-scanning thermal microscope imaging system is proposed. The technique is based on micro-scanning technology combined with the proposed second-order oversampling reconstruction algorithm and local gradient image reconstruction algorithm. In this paper, we describe the local gradient image reconstruction model, the error correction technique, down-sampling model and the error correction principle. In this paper, we use a Lena original image and four low-resolution images obtained from the standard half-pixel displacement to simulate and verify the effectiveness of the proposed technique. In order to verify the effectiveness of the proposed technique, two groups of low-resolution thermal microscope images are collected by the actual thermal microscope imaging system for experimental study. Simulations and experiments show that the proposed technique can reduce the optical micro-scanning errors, improve the imaging effect of the system and improve the system's spatial resolution. It can be applied to other electro-optical imaging systems to improve their resolution. 展开更多
关键词 thermal microscope imaging system OPTICAL micro-scanning local gradient image RECONSTRUCTION second-order OVERSAMPLING RECONSTRUCTION spatial resolution
下载PDF
Oversample Reconstruction Based on a Strong Inter-Diagonal Matrix for an Optical Microscanning Thermal Microscope Imaging System
2
作者 meijing gao Ailing Tan +3 位作者 Jie Xu Weiqi Jin Zhenlong Zu Ming Yang 《Journal of Beijing Institute of Technology》 EI CAS 2018年第1期65-73,共9页
Based on a strong inter-diagonal matrix and Taylor series expansions,an oversample reconstruction method was proposed to calibrate the optical micro-scanning error. The technique can obtain regular 2 ×2 microscan... Based on a strong inter-diagonal matrix and Taylor series expansions,an oversample reconstruction method was proposed to calibrate the optical micro-scanning error. The technique can obtain regular 2 ×2 microscanning undersampling images from the real irregular undersampling images,and can then obtain a high spatial oversample resolution image. Simulations and experiments show that the proposed technique can reduce optical micro-scanning error and improve the system's spatial resolution. The algorithm is simple,fast and has low computational complexity. It can also be applied to other electro-optical imaging systems to improve their spatial resolution and has a widespread application prospect. 展开更多
关键词 optical microscanning strong inter-diagonal matrix oversample reconstruction thermal microscope imaging system
下载PDF