期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Characterization of Simulator and Relative Spectral Responsivity Measurements of Photovoltaic Modules with Band Pass Filter Technique
1
作者 meric seval Bazkir Ozcan 《Open Journal of Energy Efficiency》 2022年第3期71-87,共17页
One of the most important parameter used for the evaluation of the energy rating of PV modules is, their spectral responsivities which are the measure of electrical performance parameters per incident solar radiation.... One of the most important parameter used for the evaluation of the energy rating of PV modules is, their spectral responsivities which are the measure of electrical performance parameters per incident solar radiation. In this work, spectral responsivity measurements of a mono-crystalline, a poly-crystalline, a CIGS thin film and a bifacial module were measured using xenon-based flash type solar simulator system and a set of band pass filters. For the comprehensive characterization of parameters that may influence the spectral responsivity measurements, initially the simulator system was characterized both optically and thermally according to the IEC60904-9 and IEC60891 standard requirements. The optical characterizations in terms of spectral match, spatial non-uniformity and temporal instability indicate that the measured results (~3.0%, ~0.30% and ~0.20%) according to the IEC 60904-9 standard’s classification requirements correspond to A+A+A+ classes. Moreover, thermal characterizations in terms of the temperature uniformity show that over the 2 × 2 m area temperature uniformity of simulator system’s light distribution (1&ordm;C) is almost two times better than the IEC 60891 standard requirements (±2&ordm;C). Next, PV modules were electrically stabilized according to the IEC 61215-2 standard requirement’s (stability test) to reduce the fluctuations in their electrical performance parameters. Then, using the band pass filters, temperature controlled xenon-based solar simulator system and a reference PV module of the spectral responsivity of PV modules were measured from 400 nm to 1100 nm with 50 nm steps with relative uncertainty of 10<sup>-3</sup> level. 展开更多
关键词 Photovoltaic Modules RESPONSIVITY Solar Simulator Band Pass Filters
下载PDF
Temperature-Irradiance Matrix and Determination of Temperature Coefficients of a Monocrystalline PV Module
2
作者 Bazkir Ozcan meric seval 《Open Journal of Energy Efficiency》 2022年第3期108-121,共14页
Photovoltaic (PV) modules performance testing and energy rating as described in IEC 61853-1 standard depend on electrical performance parameters (short-circuit current, open-circuit voltage, maximum-power) of PV modul... Photovoltaic (PV) modules performance testing and energy rating as described in IEC 61853-1 standard depend on electrical performance parameters (short-circuit current, open-circuit voltage, maximum-power) of PV modules as a function of temperature and irradiance. In this work, in order to precisely determine the effects of temperature on the electrical parameters of a monocrystalline PV module, the temperature controlled, xenon light based solar simulator system with irradiance attenuating masks was used. This solar simulator, according to the IEC 60904-9 standard in terms of spectral match, spatial non-uniformity and temporal instability has A+A+A+ classes which are two times better than the standard requirements for a solar simulator to be used in PV module measurements. Moreover, the thermal chamber used in this work is a closed type chamber with fast opening door for not allowing the distortion of temperature uniformity over the surface of PV modules under test. Within about 2 m × 2 m area within 15°C to 75°C temperature interval, the temperature uniformity obtained for this system is less than 1.0°C which is almost two times better than the IEC 60891 standard requirements (±2.0°C). The temperature and irradiance dependent measurements of the electrical performance parameters of a mono-crystalline PV module at various irradiance levels and the evaluation of its temperature coefficients [α (% °C<sup>-</sup><sup>1</sup>), β (% °C<sup>-</sup><sup>1</sup>) and δ (% °C<sup>-</sup><sup>1</sup>)] were done by implementing the interpolation method described in IEC 60891 standard. 展开更多
关键词 PHOTOVOLTAIC Temperature Coefficient LINEARITY Energy Rating
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部