The work presented in this paper serves as numerical verification of the analytical model developed in the companion paper for nonlinear dynamic analysis of multi-base seismically isolated structures. To this end, two...The work presented in this paper serves as numerical verification of the analytical model developed in the companion paper for nonlinear dynamic analysis of multi-base seismically isolated structures. To this end, two numerical examples have been analyzed using the computational algorithm incorporated into program 3D-BASIS-ME-MB, developed on the basis of the newly-formulated analytical model. The first example concerns a seven-story model structure that was tested on the earthquake simulator at the University at Buflhlo and was also used as a verification example for program SAP2000. The second example concerns a two-tower, multi-story structure with a split-level seismic-isolation system. For purposes of verification, key results produced by 3D-BASIS-ME-MB are compared to experimental results, or results obtained from other structural/finite element programs. In both examples, the analyzed structure is excited under conditions of bearing uplift, thus yielding a case of much interest in verifying the capabilities of the developed analysis tool.展开更多
The complexity of modem seismically isolated structures requires the analysis of the structural, system and the isolation system in its entirety and the ability to capture potential discontinuous phenomena such as iso...The complexity of modem seismically isolated structures requires the analysis of the structural, system and the isolation system in its entirety and the ability to capture potential discontinuous phenomena such as isolator uplift and their effects on the superstructures and the isolation hardware. In this paper, an analytical model is developed and a computational algorithm is formulated to analyze complex seismically isolated superstructures even when undergoing highly-nonlinear phenomena such as uplift. The computational model has the capability of modeling various types of isolation devices with strong nonlinearities, analyzing multiple superstructures (up to five separate superstructures) on multiple bases (up to five bases), and capturing the effects of lateral loads on bearing axial forces, including bearing uplift. The model developed herein has been utilized to form the software platform 3D-BASIS-ME-MB, which provides the practicing engineering community with a versatile tool for analysis and design of complex structures with modem isolation systems.展开更多
基金Multidisciplinary Center for Earthquake Engineering Research
文摘The work presented in this paper serves as numerical verification of the analytical model developed in the companion paper for nonlinear dynamic analysis of multi-base seismically isolated structures. To this end, two numerical examples have been analyzed using the computational algorithm incorporated into program 3D-BASIS-ME-MB, developed on the basis of the newly-formulated analytical model. The first example concerns a seven-story model structure that was tested on the earthquake simulator at the University at Buflhlo and was also used as a verification example for program SAP2000. The second example concerns a two-tower, multi-story structure with a split-level seismic-isolation system. For purposes of verification, key results produced by 3D-BASIS-ME-MB are compared to experimental results, or results obtained from other structural/finite element programs. In both examples, the analyzed structure is excited under conditions of bearing uplift, thus yielding a case of much interest in verifying the capabilities of the developed analysis tool.
基金support for this project was provided by the Multidisciplinary Center for Earthquake Engineering Research through a grant from the Earthquake Engineering Research Centers Program of the National Science Foundation under award number EEC 9701471.
文摘The complexity of modem seismically isolated structures requires the analysis of the structural, system and the isolation system in its entirety and the ability to capture potential discontinuous phenomena such as isolator uplift and their effects on the superstructures and the isolation hardware. In this paper, an analytical model is developed and a computational algorithm is formulated to analyze complex seismically isolated superstructures even when undergoing highly-nonlinear phenomena such as uplift. The computational model has the capability of modeling various types of isolation devices with strong nonlinearities, analyzing multiple superstructures (up to five separate superstructures) on multiple bases (up to five bases), and capturing the effects of lateral loads on bearing axial forces, including bearing uplift. The model developed herein has been utilized to form the software platform 3D-BASIS-ME-MB, which provides the practicing engineering community with a versatile tool for analysis and design of complex structures with modem isolation systems.