期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Dark Current Compensation and Sensitivity Adjustment on Gallium Arsenide Linear Array Detector for X-Ray Imaging
1
作者 mikhail polkovnikov 《Journal of Biomedical Science and Engineering》 2016年第11期532-543,共13页
For the last several years, the linear array x-ray detector for x-ray imaging with gallium arsenide direct conversion sensitive elements has been developed and tested at the In-stitute for High Energy Physics. The arr... For the last several years, the linear array x-ray detector for x-ray imaging with gallium arsenide direct conversion sensitive elements has been developed and tested at the In-stitute for High Energy Physics. The array consists of 16 sensitive modules. Each module has 128 gallium arsenide (GaAs) sensitive elements with 200 μm pitch. Current article describes two key program procedures of initial dark current compensation of each sensitive element in the linear array, and sensitivity adjustment for alignment of strip pattern in the raw image data. As a part of evaluation process a modular transfer function (MTF) was measured with the slanted sharp-edge object under RQA5 technique as it described in the International Electrotechnical Commission 62220-1 standard (high voltage 70 kVp, additional aluminium filter 21 mm) for images with compensated dark currents and adjusted sensitivity of detector elements. The 10% level of the calculated MTF function has spatial resolution within 2 - 3 pair of lines per mm for both vertical and horizontal orientation. 展开更多
关键词 Linear Array Gallium Arsenide CALIBRATION Dark Current Sensitivity Modular Transfer Function Normalized Noise Power Spectrum
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部