Background: Breast feeding is an ideal feeding type for most infants and mothers. We evaluated the effect of early breast-feeding and prenatal education of breast- feeding in maintenance of breast-feeding practice aft...Background: Breast feeding is an ideal feeding type for most infants and mothers. We evaluated the effect of early breast-feeding and prenatal education of breast- feeding in maintenance of breast-feeding practice after delivery. Methods: Eighty two pregnant women who experienced vaginal delivery were recruited from the department of obstetrics and gynecology of a university hospital between January 2006 and October 2006. These differences among variables were determined using SPSS ver. 10.0 (SPSS Inc., Chicago, IL, USA). Follow-up telephone interviews were conducted 1 week and 4 weeks after delivery to check feeding method for baby and other complications. Results: We calculated the correlations among the pregnant women’s age, height, and weight, abortion experience, the newborn’s weight, and social factors using ANOVA. There was no statistically significant relationship between early breast-feeding and maintenance of breast-feeding practice. Conclusions: Antenatal and post- partum period education about breast-feeding is necessary for breast-feeding practice maintenance. Further studies in developing educational programs are needed.展开更多
Various approaches have been proposed for point-of-care diagnostics, and in particular, optical detection is preferred because it is relatively simple and fast. At the same time, field-effect transistor (FET)-based ...Various approaches have been proposed for point-of-care diagnostics, and in particular, optical detection is preferred because it is relatively simple and fast. At the same time, field-effect transistor (FET)-based biosensors have attracted great attention because they can provide highly sensitive and label-free detection. In this work we present highly sensitive, epidermal skin-type point-of-care devices with system-level integration of flexible MOS2 FET biosensors, read-out circuits, and light-emitting diode (LEDs) that enable real-time detection of prostate cancer antigens (PSA). Regardless of the physical forms or mechanical stress conditions, our proposed high-performance MoS2 biosensors can detect a PSA concentration of 1 pg.mL-1 without specific surface treatment for anti-PSA immobilization on the MoS2 surface on which we characterize and confirm physisorption of anti-PSA using Kelvin probe force microscopy (KPFM) and tapping-mode atomic force microscopy (tm-AFM). Furthermore, current modulation induced by the binding process was stably maintained for longer than 2-3 min. The results indicate that flexible MoS2-based FET biosensors have great potential for point-of-care diagnostics for prostate cancer as well as other biomarkers.展开更多
The second affiliation of the authors in the original version of this article was unfortunately wrongly written on the first page, instead of Multi-Functional Nano/Bio Electronics Lab., Kyung Hee University, Gyeonggi ...The second affiliation of the authors in the original version of this article was unfortunately wrongly written on the first page, instead of Multi-Functional Nano/Bio Electronics Lab., Kyung Hee University, Gyeonggi 17104, Republic of Korea.展开更多
文摘Background: Breast feeding is an ideal feeding type for most infants and mothers. We evaluated the effect of early breast-feeding and prenatal education of breast- feeding in maintenance of breast-feeding practice after delivery. Methods: Eighty two pregnant women who experienced vaginal delivery were recruited from the department of obstetrics and gynecology of a university hospital between January 2006 and October 2006. These differences among variables were determined using SPSS ver. 10.0 (SPSS Inc., Chicago, IL, USA). Follow-up telephone interviews were conducted 1 week and 4 weeks after delivery to check feeding method for baby and other complications. Results: We calculated the correlations among the pregnant women’s age, height, and weight, abortion experience, the newborn’s weight, and social factors using ANOVA. There was no statistically significant relationship between early breast-feeding and maintenance of breast-feeding practice. Conclusions: Antenatal and post- partum period education about breast-feeding is necessary for breast-feeding practice maintenance. Further studies in developing educational programs are needed.
文摘Various approaches have been proposed for point-of-care diagnostics, and in particular, optical detection is preferred because it is relatively simple and fast. At the same time, field-effect transistor (FET)-based biosensors have attracted great attention because they can provide highly sensitive and label-free detection. In this work we present highly sensitive, epidermal skin-type point-of-care devices with system-level integration of flexible MOS2 FET biosensors, read-out circuits, and light-emitting diode (LEDs) that enable real-time detection of prostate cancer antigens (PSA). Regardless of the physical forms or mechanical stress conditions, our proposed high-performance MoS2 biosensors can detect a PSA concentration of 1 pg.mL-1 without specific surface treatment for anti-PSA immobilization on the MoS2 surface on which we characterize and confirm physisorption of anti-PSA using Kelvin probe force microscopy (KPFM) and tapping-mode atomic force microscopy (tm-AFM). Furthermore, current modulation induced by the binding process was stably maintained for longer than 2-3 min. The results indicate that flexible MoS2-based FET biosensors have great potential for point-of-care diagnostics for prostate cancer as well as other biomarkers.
文摘The second affiliation of the authors in the original version of this article was unfortunately wrongly written on the first page, instead of Multi-Functional Nano/Bio Electronics Lab., Kyung Hee University, Gyeonggi 17104, Republic of Korea.