AIM: To evaluate the safety and efficacy of the permanent high interventricular septal pacing in a long term follow up, as alternative to right ventricular apical pacing. METHODS: We retrospectively evaluated:(1) 244 ...AIM: To evaluate the safety and efficacy of the permanent high interventricular septal pacing in a long term follow up, as alternative to right ventricular apical pacing. METHODS: We retrospectively evaluated:(1) 244 patients(74 ± 8 years; 169 men, 75 women) implanted with a single(132 pts) or dual chamber(112 pts) pacemaker(PM) with ventricular screw-in lead placed at the right ventricular high septal parahisian site(SEPTAL pacing);(2) 22 patients with permanent pacemaker and low percentage of pacing(< 20%)(NO pacing);(3) 33 patients with high percentage(> 80%) right ventricular apical pacing(RVA). All patients had a narrow spontaneous QRS(101 ± 14 ms). We evaluated New York Heart Association(NYHA) class, quality of life(Qo L), 6 min walking test(6MWT) and left ventricular function(end-diastolic volume, LV-EDV; end-systolic volume, LVESV; ejection fraction, LV-EF) with 2D-echocardiography. RESULTS: Pacing parameters were stable duringfollow up(21 mo/patient). In SEPTAL pacing group we observed an improvement in NYHA class, Qo L score and 6MWT. While LV-EDV didn't significantly increase(104 ± 40 m L vs 100 ± 37 m L; P = 0.35), LV-ESV slightly increased(55 ± 31 m L vs 49 ± 27 m L; P = 0.05) and LV-EF slightly decreased(49% ± 11% vs 53% ± 11%; P = 0.001) but never falling < 45%. In the RVA pacing control group we observed a worsening of NYHA class and an important reduction of LV-EF(from 56% ± 6% to 43% ± 9%, P < 0.0001).CONCLUSION: Right ventricular permanent high septal pacing is safe and effective in a long term follow up evaluation; it could be a good alternative to the conventional RVA pacing in order to avoid its deleterious effects.展开更多
The right atrial appendage (RAA) and right ventricular apex (RVA) have been widely considered as conventional sites for typical dual-chamber atrio-ventricular cardiac (DDD) pacing. Unfortunately conventional RAA pacin...The right atrial appendage (RAA) and right ventricular apex (RVA) have been widely considered as conventional sites for typical dual-chamber atrio-ventricular cardiac (DDD) pacing. Unfortunately conventional RAA pacing seems not to be able to prevent atrial fibrillation in DDD pacing for tachycardia-bradycardia syndrome, and the presence of a left bundle branch type of activation induced by RVA pacing can have negative effects. A new technology with active screw-in leads permits a more physiological atrial and right ventricular pacing. In this review, we highlight the positive effects of pacing of these new and easily selected sites. The septal atrial lead permits a shorter and more homogeneous atrial activation, allowing better prevention of paroxysmal atrial fibrillation. The para-Hisian pacing can be achieved in a simpler and more reliable way with respect to biventricular pacing and direct Hisian pacing. We await larger trials to consider this "easy and physiological pacing" as a first approach in patients who need a high frequency of pacing.展开更多
Takotsubo cardiomyopathy typically affects post-menopausal women under severe psychological or physical stress; it also has been reported to develop after medical procedures or surgery. We herein report the rare case ...Takotsubo cardiomyopathy typically affects post-menopausal women under severe psychological or physical stress; it also has been reported to develop after medical procedures or surgery. We herein report the rare case of a 30-year-old woman who presented with an episode of ventricular fibrillation after a very complicated cesarean delivery and was successfully resuscitated. Subsequent electrocardiography and echocardiography showed a typical Takotsubo pattern. Within 3 wk, left ventricular systolic function returned to normal.展开更多
文摘AIM: To evaluate the safety and efficacy of the permanent high interventricular septal pacing in a long term follow up, as alternative to right ventricular apical pacing. METHODS: We retrospectively evaluated:(1) 244 patients(74 ± 8 years; 169 men, 75 women) implanted with a single(132 pts) or dual chamber(112 pts) pacemaker(PM) with ventricular screw-in lead placed at the right ventricular high septal parahisian site(SEPTAL pacing);(2) 22 patients with permanent pacemaker and low percentage of pacing(< 20%)(NO pacing);(3) 33 patients with high percentage(> 80%) right ventricular apical pacing(RVA). All patients had a narrow spontaneous QRS(101 ± 14 ms). We evaluated New York Heart Association(NYHA) class, quality of life(Qo L), 6 min walking test(6MWT) and left ventricular function(end-diastolic volume, LV-EDV; end-systolic volume, LVESV; ejection fraction, LV-EF) with 2D-echocardiography. RESULTS: Pacing parameters were stable duringfollow up(21 mo/patient). In SEPTAL pacing group we observed an improvement in NYHA class, Qo L score and 6MWT. While LV-EDV didn't significantly increase(104 ± 40 m L vs 100 ± 37 m L; P = 0.35), LV-ESV slightly increased(55 ± 31 m L vs 49 ± 27 m L; P = 0.05) and LV-EF slightly decreased(49% ± 11% vs 53% ± 11%; P = 0.001) but never falling < 45%. In the RVA pacing control group we observed a worsening of NYHA class and an important reduction of LV-EF(from 56% ± 6% to 43% ± 9%, P < 0.0001).CONCLUSION: Right ventricular permanent high septal pacing is safe and effective in a long term follow up evaluation; it could be a good alternative to the conventional RVA pacing in order to avoid its deleterious effects.
文摘The right atrial appendage (RAA) and right ventricular apex (RVA) have been widely considered as conventional sites for typical dual-chamber atrio-ventricular cardiac (DDD) pacing. Unfortunately conventional RAA pacing seems not to be able to prevent atrial fibrillation in DDD pacing for tachycardia-bradycardia syndrome, and the presence of a left bundle branch type of activation induced by RVA pacing can have negative effects. A new technology with active screw-in leads permits a more physiological atrial and right ventricular pacing. In this review, we highlight the positive effects of pacing of these new and easily selected sites. The septal atrial lead permits a shorter and more homogeneous atrial activation, allowing better prevention of paroxysmal atrial fibrillation. The para-Hisian pacing can be achieved in a simpler and more reliable way with respect to biventricular pacing and direct Hisian pacing. We await larger trials to consider this "easy and physiological pacing" as a first approach in patients who need a high frequency of pacing.
文摘Takotsubo cardiomyopathy typically affects post-menopausal women under severe psychological or physical stress; it also has been reported to develop after medical procedures or surgery. We herein report the rare case of a 30-year-old woman who presented with an episode of ventricular fibrillation after a very complicated cesarean delivery and was successfully resuscitated. Subsequent electrocardiography and echocardiography showed a typical Takotsubo pattern. Within 3 wk, left ventricular systolic function returned to normal.