We present the ferroresonance overvoltage mitigation concerning the power systems of the grid-connectcd wind energy conversion systems(WECSs).WECS is considered based on a doubly-fed induction generator(DFIG).Ferrores...We present the ferroresonance overvoltage mitigation concerning the power systems of the grid-connectcd wind energy conversion systems(WECSs).WECS is considered based on a doubly-fed induction generator(DFIG).Ferroresonance overvoltage associated with a single-pole outage of the line breaker is mitigated by fast regulating the reactive power using the static compensator(STATCOM).STATCOM controller is introduced,in which t>\o incorporated proportional-integral(PI)controllers are optimally tuned using a modified flow-er pollination algorithm(MFPA)as an optimization technique.To show the capability of the proposed STATCOM controller in mitigating the ferroresonance overvoltage,two test cases are introduced,which are based on the interconnection status of the power transformer used with the grid-connected DFIGs.The results show that the ferroresonance disturbance can occur for the power transformers installed in the wind farms although the transformer terminals are interconnected,and neither side of the transformer is isolated.Furthermore,as a mitigation method of ferroresonance overvoltage,the proposed STATCOM controller succeeds in improving the system voltage profile and speed profile of the wind turbine as well as protecting the system components against the ferroresonance overvoltage.展开更多
文摘We present the ferroresonance overvoltage mitigation concerning the power systems of the grid-connectcd wind energy conversion systems(WECSs).WECS is considered based on a doubly-fed induction generator(DFIG).Ferroresonance overvoltage associated with a single-pole outage of the line breaker is mitigated by fast regulating the reactive power using the static compensator(STATCOM).STATCOM controller is introduced,in which t>\o incorporated proportional-integral(PI)controllers are optimally tuned using a modified flow-er pollination algorithm(MFPA)as an optimization technique.To show the capability of the proposed STATCOM controller in mitigating the ferroresonance overvoltage,two test cases are introduced,which are based on the interconnection status of the power transformer used with the grid-connected DFIGs.The results show that the ferroresonance disturbance can occur for the power transformers installed in the wind farms although the transformer terminals are interconnected,and neither side of the transformer is isolated.Furthermore,as a mitigation method of ferroresonance overvoltage,the proposed STATCOM controller succeeds in improving the system voltage profile and speed profile of the wind turbine as well as protecting the system components against the ferroresonance overvoltage.