In this paper,a new type of automatic transmitter(AT)is proposed to properly adjust the voltage of the train without installing additional equipment.The proposed tap-changing AT is expected to raise the voltage betwee...In this paper,a new type of automatic transmitter(AT)is proposed to properly adjust the voltage of the train without installing additional equipment.The proposed tap-changing AT is expected to raise the voltage between catenary and rail by regulating the turn-ratio between primary and secondary winding according to catenary voltage and verified its effects through the multi ports network analysis technique modeling of it.Through the simulation and analysis of the electric railway systems,it is shown that it can secure the load capacity and solve the large voltage drop problem by raising the voltage across railway vehicles back to the normal voltage level.展开更多
基金KETEP(Korea Institute of Energy Technology Evaluation and Planning)grant funded by the Korea government(MOTIE)(No.20191210301890)。
文摘In this paper,a new type of automatic transmitter(AT)is proposed to properly adjust the voltage of the train without installing additional equipment.The proposed tap-changing AT is expected to raise the voltage between catenary and rail by regulating the turn-ratio between primary and secondary winding according to catenary voltage and verified its effects through the multi ports network analysis technique modeling of it.Through the simulation and analysis of the electric railway systems,it is shown that it can secure the load capacity and solve the large voltage drop problem by raising the voltage across railway vehicles back to the normal voltage level.