期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Validating the accuracy of a multifunctional smartwatch sphygmomanometer to monitor blood pressure 被引量:3
1
作者 li YI Zhong-Hua LV +13 位作者 Shun-Ying HU Yu-Qi liU Jia-Bing YAN Hui Zhang Hong-Bao li Qin CHEN Yue-Yang li Yu-Fan JIANG Hao ZHOU mu-ding li Run-Du CHEN Xiao-Long li Shan-Shan ZHOU Yun-Dai CHEN 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2022年第11期843-852,共10页
BACKGROUND Hypertension is the most modifiable factor associated with cardiovascular events and complications.The conventional blood pressure(BP) meter method is simple but is limited in terms of real-time monitoring ... BACKGROUND Hypertension is the most modifiable factor associated with cardiovascular events and complications.The conventional blood pressure(BP) meter method is simple but is limited in terms of real-time monitoring abnormal BP.Therefore,the development of a multifunction smartwatch(HUAWEI WATCH D) sphygmomanometer could significantly improve integrated BP monitoring.METHODS We enrolled 361 subjects from Chinese PL A General Hospital,Beijing,China to validate the accuracy of the smartwatch versatile sphygmomanometer using ISO 81060-2:2018.Resting and ambulatory BP accuracy of the smartwatch were compared with gold standard clinical sphygmomanometers using ISO 81060-2:2018 guidelines,the accuracy of 24 h systolic blood pressure(SBP) circadian rhythm monitoring,and diurnal high SBP alert for this smartwatch were assessed using a confusion matrix approach.Additionally,we analyzed online users of different ages for compliance.RESULTS Eighty-five subjects underwent resting BP measurements;the mean resting BP differences between two devices were-0.683±6.203 mmHg(SBP)(P=0.723) and 1.628±5.028 mmHg(diastolic blood pressure,DBP)(P=0.183).In 35 subjects’ ambulatory BP measurements,the mean differences of ambulatory BP were-1.943±5.475 mmHg(SBP)(P=0.923) and 3.195±5.862 mmHg(DBP)(P=0.065).All data complied with ISO 81060-2:2018 guidelines(mean ≤±5 mmHg and standard deviation ≤±8 mmHg) with no significant differences.Positive predictive values(PPV) of resting SBP and DBP were 0.635 and 0.671,respectively.The PPV of ambulatory SBP and DBP were 0.686.Also,24 h SBP circadian rhythm monitoring was performed in 107 subjects:accuracy=0.850,specificity=0.864,precision/PPV=0.833,sensitivity=0.833,and F1-measure(F1)=0.833.The accuracy,specificity,precision,sensitivity,and F1 values in 85 subjects undergoing diurnal high SBP alerting were 0.858,0.876,0.706,0.809,and 0.754,respectively.CONCLUSIONS When compared with the gold standard clinical sphygmomanometer,smartwatch results were consistent and accurate.Online user feedback showed that elderly individuals cared more about BP monitoring accuracy,with better compliance. 展开更多
关键词 SPECIFICITY smart DATING
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部