Intraoperative Fracture of the Femur in Revision Total Hip Arthroplasty with a Fully HA-Coated Stem
1
作者 David E. Rothem Lilah Rothem +3 位作者 Alexander Lerner Tal Salamon Richard Hiscock neil bergman 《Open Journal of Orthopedics》 2014年第3期70-76,共7页
A retrospective review was made of intraoperative femoral fracture prevalence in seventy nine consecutive, cementless, fully HA-coated stems used for revision hip arthroplasty. Three patients were lost to follow up. I... A retrospective review was made of intraoperative femoral fracture prevalence in seventy nine consecutive, cementless, fully HA-coated stems used for revision hip arthroplasty. Three patients were lost to follow up. Intraoperative fracture occurred in 15 (20%) femurs. Fractures occurred during cement removal (3/15) or insertion of the implant (12/15). All fractures were identified using intraoperative biplane X-ray, and were treated during the same operation. The clinical outcome of both groups (with or without fractures) was similar. The risk of intraoperative fracture was not statistically related to any demographic features or operative technique. Intraoperative radiographs are therefore mandatory in revision hip arthroplasty in order to diagnose and treat the common complication of femur fracture appropriately. 展开更多
关键词 Revision Hip ARTHROPLASTY INTRAOPERATIVE FRACTURE Fully Coated HA STEM Femoral PERIPROSTHETIC FRACTURE