BACKGROUND Recurrence of hepatocellular carcinoma(HCC)following liver transplantation(LT)has a devastating influence on recipients’survival;however,the risk of recur-rence is not routinely stratified.Risk stratificat...BACKGROUND Recurrence of hepatocellular carcinoma(HCC)following liver transplantation(LT)has a devastating influence on recipients’survival;however,the risk of recur-rence is not routinely stratified.Risk stratification is vital with a long LT waiting time,as that could influence the recurrence despite strict listing criteria.AIM This study aims to identify predictors of recurrence and develop a novel risk pre-diction score to forecast HCC recurrence following LT.METHODS A retrospective review of LT for HCC recipients at University Hospitals Bir-mingham between July 2011 and February 2020.Univariate and multivariate analyses were performed to identify recurrence predictors,based on which the novel SIMAP500(satellite nodules,increase in size,microvascular invasion,AFP>500,poor differentiation)risk score was proposed.RESULTS 234 LTs for HCC were performed with a median follow-up of 5.3 years.Recurrence developed in 25 patients(10.7%).On univariate analyses,RETREAT score>3,α-fetoprotein(AFP)at listing 100-500 and>500,bridging,increased tumour size between imaging at the listing time and explant histology,increase in the size of viable tumour between listing and explant,presence of satellite nodules,micro-and macrovascular invasion on explant and poor differentiation of tumours were significantly associated with recurrence,based on which,the SIMAP500 risk score is proposed.The SIMAP500 demonstrated an excellent predictive ability(c-index=0.803)and outper-formed the RETREAT score(c-index=0.73).SIMAP500 is indicative of the time to disease recurrence.CONCLUSION SIMAP500 risk score identifies the LT recipients at risk of HCC recurrence.Risk stratification allows patient-centric post-transplant surveillance programs.Further validation of the score is recommended.展开更多
Diagnostic imaging plays a key role in the diagnosis and management of inflammatory bowel disease(IBD). However due to the relapsing nature of IBD, there is growing concern that IBD patients may be exposed to potentia...Diagnostic imaging plays a key role in the diagnosis and management of inflammatory bowel disease(IBD). However due to the relapsing nature of IBD, there is growing concern that IBD patients may be exposed to potentially harmful cumulative levels of ionising radiation in their lifetime, increasing malignant potential in a population already at risk. In this review we explore the proportion of IBD patients exposed to high cumulative radiation doses, the risk factors associated with higher radiation exposures, and we compare conventional diagnostic imaging with newer radiation-free imaging techniques used in the evaluation of patients with IBD. While computed tomography(CT) performs well as an imaging modality for IBD, the effective radiation dose is considerably higher than other abdominal imaging modalities. It is increasingly recognised that CT imaging remains responsible for the majority of diagnostic medical radiation to which IBD patients are exposed. Magnetic resonance imaging(MRI) and small intestine contrast enhanced ultrasonography(SICUS) have now emerged as suitable radiation-free alternatives to CT imaging, with comparable diagnostic accuracy. The routine use of MRI and SICUS for the clinical evaluation of patients with known or suspected small bowel Crohn's disease is to be encouraged wherever possible. More provision is needed for out-of-hours radiation-free imaging modalities to reduce the need for CT.展开更多
文摘BACKGROUND Recurrence of hepatocellular carcinoma(HCC)following liver transplantation(LT)has a devastating influence on recipients’survival;however,the risk of recur-rence is not routinely stratified.Risk stratification is vital with a long LT waiting time,as that could influence the recurrence despite strict listing criteria.AIM This study aims to identify predictors of recurrence and develop a novel risk pre-diction score to forecast HCC recurrence following LT.METHODS A retrospective review of LT for HCC recipients at University Hospitals Bir-mingham between July 2011 and February 2020.Univariate and multivariate analyses were performed to identify recurrence predictors,based on which the novel SIMAP500(satellite nodules,increase in size,microvascular invasion,AFP>500,poor differentiation)risk score was proposed.RESULTS 234 LTs for HCC were performed with a median follow-up of 5.3 years.Recurrence developed in 25 patients(10.7%).On univariate analyses,RETREAT score>3,α-fetoprotein(AFP)at listing 100-500 and>500,bridging,increased tumour size between imaging at the listing time and explant histology,increase in the size of viable tumour between listing and explant,presence of satellite nodules,micro-and macrovascular invasion on explant and poor differentiation of tumours were significantly associated with recurrence,based on which,the SIMAP500 risk score is proposed.The SIMAP500 demonstrated an excellent predictive ability(c-index=0.803)and outper-formed the RETREAT score(c-index=0.73).SIMAP500 is indicative of the time to disease recurrence.CONCLUSION SIMAP500 risk score identifies the LT recipients at risk of HCC recurrence.Risk stratification allows patient-centric post-transplant surveillance programs.Further validation of the score is recommended.
文摘Diagnostic imaging plays a key role in the diagnosis and management of inflammatory bowel disease(IBD). However due to the relapsing nature of IBD, there is growing concern that IBD patients may be exposed to potentially harmful cumulative levels of ionising radiation in their lifetime, increasing malignant potential in a population already at risk. In this review we explore the proportion of IBD patients exposed to high cumulative radiation doses, the risk factors associated with higher radiation exposures, and we compare conventional diagnostic imaging with newer radiation-free imaging techniques used in the evaluation of patients with IBD. While computed tomography(CT) performs well as an imaging modality for IBD, the effective radiation dose is considerably higher than other abdominal imaging modalities. It is increasingly recognised that CT imaging remains responsible for the majority of diagnostic medical radiation to which IBD patients are exposed. Magnetic resonance imaging(MRI) and small intestine contrast enhanced ultrasonography(SICUS) have now emerged as suitable radiation-free alternatives to CT imaging, with comparable diagnostic accuracy. The routine use of MRI and SICUS for the clinical evaluation of patients with known or suspected small bowel Crohn's disease is to be encouraged wherever possible. More provision is needed for out-of-hours radiation-free imaging modalities to reduce the need for CT.