This paper presents the harmonic state estimation (HSE) based on the Total Least Squares (TLS) through comprehensively considering the harmonic network parameter error and measurement system error. The proposed approa...This paper presents the harmonic state estimation (HSE) based on the Total Least Squares (TLS) through comprehensively considering the harmonic network parameter error and measurement system error. The proposed approach is tested on the IEEE 14–bus harmonic testing system. The satisfied results are obtained.展开更多
The penetration of distributed energy resources(DERs) and energy-intensive resources is gradually increasing in active distribution networks(ADNs), which leads to frequent and severe voltage violation problems. As a d...The penetration of distributed energy resources(DERs) and energy-intensive resources is gradually increasing in active distribution networks(ADNs), which leads to frequent and severe voltage violation problems. As a densely distributed flexible resource in the future distribution network, 5G base station(BS) backup battery is used to regulate the voltage profile of ADN in this paper. First, the dispatchable potential of 5G BS backup batteries is analyzed. Considering the spatial-temporal characteristics of electric load for 5G BS, the dispatchable capacity of backup batteries at different time intervals is evaluated based on historical heat map data. Then, a voltage profile optimization model for ADN is established, consisting of 5G BS backup batteries and other voltage regulation resources. In this model, the charging/discharging behavior of backup batteries is based on its evaluation result of dispatchable capacity. Finally, the range of charging/discharging cost coefficients of 5G BS that benefits ADN and 5G operators are analyzed respectively. Further, an incentive policy for 5G operators is proposed. Under this policy, the charging/discharging cost coefficients of 5G BS can achieve a win-win situation for ADN and 5G operators. As an emerging flexible resource in ADN, the effectiveness and economy of 5G BS backup batteries participating in voltage profile optimization are verified in a test distribution network.展开更多
The deployment of dynamic reactive power sourcecan effectively improve the voltage performance after a disturbance for a power system with increasing wind power penetration level and ubiquitous induction loads.To impr...The deployment of dynamic reactive power sourcecan effectively improve the voltage performance after a disturbance for a power system with increasing wind power penetration level and ubiquitous induction loads.To improve the voltage stability of the power system,this paper proposes an adaptive many-objective robust optimization model to deal with thedeployment issue of dynamic reactive power sources.Firstly,two metrics are adopted to assess the voltage stability of the system at two different stages,and one metric is proposed to assess the tie-line reactive power flow.Then,a robustness index isdeveloped to assess the sensitivity of a solution when subjectedto operational uncertainties,using the estimation of acceptablesensitivity region(ASR)and D-vine Copula.Five objectives areoptimized simultaneously:①total equipment investment;②adaptive short-term voltage stability evaluation;③tie-line power flow evaluation;④prioritized steady-state voltage stabilityevaluation;and⑤robustness evaluation.Finally,an anglebased adaptive many-objective evolutionary algorithm(MaOEA)is developed with two improvements designed for the application in a practical engineering problem:①adaptive mutationrate;and②elimination procedure without a requirement for athreshold value.The proposed model is verified on a modifiedNordic 74-bus system and a real-world power system.Numerical results demonstrate the effectiveness and efficiency of theproposed model.展开更多
Bipolar direct current(DC)distribution networks can effectively improve the connection flexibility for renewable generations and loads.In practice,concerns regarding the potential voltage unbalance issue of the distri...Bipolar direct current(DC)distribution networks can effectively improve the connection flexibility for renewable generations and loads.In practice,concerns regarding the potential voltage unbalance issue of the distribution networks and the frequency of switching still remain.This paper proposes a day-ahead polarity switching strategy to reduce voltage unbalance by optimally switching the polarity of renewable generations and loads while minimizing the switching times simultaneously in the range of a full day.First,a multi-objective optimization model is constructed to minimize the weighted sum of voltage unbalance factors and the sum of number of switching actions in the day based on the power flow model.Second,a two-step solution strategy is proposed to solve the optimization model.Finally,the proposed strategy is validated using 11-node and 34-node distribution networks as case studies,and a switching and stabilizing device is designed to enable unified switching of renewable generations and loads.Numerical results demonstrate that the proposed strategy can effectively reduce the switching times without affecting the improvement of voltage balance.展开更多
To optimize the placement of soft open points(SOPs)in active distribution networks(ADNs),many aspects should be considered,including the adjustment of transmission power,integration of distributed generations(DGs),coo...To optimize the placement of soft open points(SOPs)in active distribution networks(ADNs),many aspects should be considered,including the adjustment of transmission power,integration of distributed generations(DGs),coordination with conventional control methods,and maintenance of economic costs.To address this multi-objective planning problem,this study proposes a multi-stage coordinated robust optimization model for the SOP allocation in ADNs with photovoltaic(PV).First,two robust technical indices based on a robustness index are proposed to evaluate the operation conditions and robust optimality of the solutions.Second,the proposed coordinated allocation model aims to optimize the total cost,robust voltage offset index,robust utilization index,and voltage collapse proximity index.Third,the optimization methods of the multiand single-objective models are coordinated to solve the proposed multi-stage problem.Finally,the proposed model is implemented on an IEEE 33-node distribution system to verify its effectiveness.Numerical results show that the proposed index can better reveal voltage offset conditions as well as the SOP utilization,and the proposed model outperforms conventional ones in terms of robustness of placement plans and total cost.展开更多
The two main challenges of medium voltage direct current(MVDC)distribution network are the flexible control of power flow(PF)and fault protection.In this paper,the power flow controller(PFC)is introduced to regulate t...The two main challenges of medium voltage direct current(MVDC)distribution network are the flexible control of power flow(PF)and fault protection.In this paper,the power flow controller(PFC)is introduced to regulate the PF and inhibit the fault current during the DC fault.The coordination strategy of series-parallel PFC(SP-PFC)and hybrid DC circuit breaker(DCCB)is proposed.By regulating the polarity and magnitude of SP-PFC output voltage during the fault,the rising speed of fault current can be suppressed so as to reduce the breaking current of hybrid DCCB.The access mode of SP-PFC to the MVDC distribution network and its topology are analyzed,and the coordination strategy between SP-PFC and hybrid DCCB is investigated.Moreover,the emergency control and bypass control strategies of SP-PFC are developed.On this basis,the mathematical model of SP-PFC in different fault stages is derived.With the equivalent model of SP-PFC,the fault current of the MVDC distribution network can be calculated accurately.A simulation model of the MVDC distribution network containing SP-PFC is established in MATLAB/Simulink.The fault current calculation result is compared with the simulation result,and the effectiveness of the proposed coordination strategy is verified.展开更多
In northern China,thermal power units(TPUs)are important in improving the penetration level of renewable energy.In such areas,the potentials of coordinated dispatch of renewable energy sources(RESs)and TPUs can be bet...In northern China,thermal power units(TPUs)are important in improving the penetration level of renewable energy.In such areas,the potentials of coordinated dispatch of renewable energy sources(RESs)and TPUs can be better realized,if RESs and TPUs connected to the power grid at the same point of common coupling(PCC)are dispatched as a coupled system.Firstly,the definition of the coupled system is introduced,followed by an analysis on its characteristics.Secondly,based on the operation characteristics of deep peak regulation(DPR)of TPUs in the coupled system,the constraint of the ladder-type ramping rate applicable for day-ahead dispatch is proposed,and the corresponding flexible spinning reserve constraint is further established.Then,considering these constraints and peak regulation ancillary services,a day-ahead optimal dispatch model of the coupled system is established.Finally,the operational characteristics and advantages of the coupled system are analyzed in several case studies based on a real-world power grid in Liaoning province,China.The numerical results show that the coupled system can further improve the economic benefits of RESs and TPUs under the existing policies.展开更多
文摘This paper presents the harmonic state estimation (HSE) based on the Total Least Squares (TLS) through comprehensively considering the harmonic network parameter error and measurement system error. The proposed approach is tested on the IEEE 14–bus harmonic testing system. The satisfied results are obtained.
基金supported by the National Natural Science Foundation of China (No.52077017)。
文摘The penetration of distributed energy resources(DERs) and energy-intensive resources is gradually increasing in active distribution networks(ADNs), which leads to frequent and severe voltage violation problems. As a densely distributed flexible resource in the future distribution network, 5G base station(BS) backup battery is used to regulate the voltage profile of ADN in this paper. First, the dispatchable potential of 5G BS backup batteries is analyzed. Considering the spatial-temporal characteristics of electric load for 5G BS, the dispatchable capacity of backup batteries at different time intervals is evaluated based on historical heat map data. Then, a voltage profile optimization model for ADN is established, consisting of 5G BS backup batteries and other voltage regulation resources. In this model, the charging/discharging behavior of backup batteries is based on its evaluation result of dispatchable capacity. Finally, the range of charging/discharging cost coefficients of 5G BS that benefits ADN and 5G operators are analyzed respectively. Further, an incentive policy for 5G operators is proposed. Under this policy, the charging/discharging cost coefficients of 5G BS can achieve a win-win situation for ADN and 5G operators. As an emerging flexible resource in ADN, the effectiveness and economy of 5G BS backup batteries participating in voltage profile optimization are verified in a test distribution network.
基金supported by the International Postdoctoral Exchange Fellowship Program (Talent-Introduction Program)(No.YJ20210337)the Fundamental Research Funds for the Central Universities (No.2022CDJXY-007)。
文摘The deployment of dynamic reactive power sourcecan effectively improve the voltage performance after a disturbance for a power system with increasing wind power penetration level and ubiquitous induction loads.To improve the voltage stability of the power system,this paper proposes an adaptive many-objective robust optimization model to deal with thedeployment issue of dynamic reactive power sources.Firstly,two metrics are adopted to assess the voltage stability of the system at two different stages,and one metric is proposed to assess the tie-line reactive power flow.Then,a robustness index isdeveloped to assess the sensitivity of a solution when subjectedto operational uncertainties,using the estimation of acceptablesensitivity region(ASR)and D-vine Copula.Five objectives areoptimized simultaneously:①total equipment investment;②adaptive short-term voltage stability evaluation;③tie-line power flow evaluation;④prioritized steady-state voltage stabilityevaluation;and⑤robustness evaluation.Finally,an anglebased adaptive many-objective evolutionary algorithm(MaOEA)is developed with two improvements designed for the application in a practical engineering problem:①adaptive mutationrate;and②elimination procedure without a requirement for athreshold value.The proposed model is verified on a modifiedNordic 74-bus system and a real-world power system.Numerical results demonstrate the effectiveness and efficiency of theproposed model.
基金supported by Fundamental Research Funds for the Central Universities(No.2022CDJXY-007)。
文摘Bipolar direct current(DC)distribution networks can effectively improve the connection flexibility for renewable generations and loads.In practice,concerns regarding the potential voltage unbalance issue of the distribution networks and the frequency of switching still remain.This paper proposes a day-ahead polarity switching strategy to reduce voltage unbalance by optimally switching the polarity of renewable generations and loads while minimizing the switching times simultaneously in the range of a full day.First,a multi-objective optimization model is constructed to minimize the weighted sum of voltage unbalance factors and the sum of number of switching actions in the day based on the power flow model.Second,a two-step solution strategy is proposed to solve the optimization model.Finally,the proposed strategy is validated using 11-node and 34-node distribution networks as case studies,and a switching and stabilizing device is designed to enable unified switching of renewable generations and loads.Numerical results demonstrate that the proposed strategy can effectively reduce the switching times without affecting the improvement of voltage balance.
基金supported in part by the National Natural Science Foundation of China(General Program)(No.52077017)the International Postdoctoral Exchange Fellowship Program(Talent-Introduction Program)(No.YJ20210337)。
文摘To optimize the placement of soft open points(SOPs)in active distribution networks(ADNs),many aspects should be considered,including the adjustment of transmission power,integration of distributed generations(DGs),coordination with conventional control methods,and maintenance of economic costs.To address this multi-objective planning problem,this study proposes a multi-stage coordinated robust optimization model for the SOP allocation in ADNs with photovoltaic(PV).First,two robust technical indices based on a robustness index are proposed to evaluate the operation conditions and robust optimality of the solutions.Second,the proposed coordinated allocation model aims to optimize the total cost,robust voltage offset index,robust utilization index,and voltage collapse proximity index.Third,the optimization methods of the multiand single-objective models are coordinated to solve the proposed multi-stage problem.Finally,the proposed model is implemented on an IEEE 33-node distribution system to verify its effectiveness.Numerical results show that the proposed index can better reveal voltage offset conditions as well as the SOP utilization,and the proposed model outperforms conventional ones in terms of robustness of placement plans and total cost.
基金supported by the National Key Research and Development Program of China(No.2018YFB0904600)the National Natural Science Foundation of China(No.52077017)。
文摘The two main challenges of medium voltage direct current(MVDC)distribution network are the flexible control of power flow(PF)and fault protection.In this paper,the power flow controller(PFC)is introduced to regulate the PF and inhibit the fault current during the DC fault.The coordination strategy of series-parallel PFC(SP-PFC)and hybrid DC circuit breaker(DCCB)is proposed.By regulating the polarity and magnitude of SP-PFC output voltage during the fault,the rising speed of fault current can be suppressed so as to reduce the breaking current of hybrid DCCB.The access mode of SP-PFC to the MVDC distribution network and its topology are analyzed,and the coordination strategy between SP-PFC and hybrid DCCB is investigated.Moreover,the emergency control and bypass control strategies of SP-PFC are developed.On this basis,the mathematical model of SP-PFC in different fault stages is derived.With the equivalent model of SP-PFC,the fault current of the MVDC distribution network can be calculated accurately.A simulation model of the MVDC distribution network containing SP-PFC is established in MATLAB/Simulink.The fault current calculation result is compared with the simulation result,and the effectiveness of the proposed coordination strategy is verified.
基金supported in part by the National Key Research and Development Program of China(No.2019YFB1505400).
文摘In northern China,thermal power units(TPUs)are important in improving the penetration level of renewable energy.In such areas,the potentials of coordinated dispatch of renewable energy sources(RESs)and TPUs can be better realized,if RESs and TPUs connected to the power grid at the same point of common coupling(PCC)are dispatched as a coupled system.Firstly,the definition of the coupled system is introduced,followed by an analysis on its characteristics.Secondly,based on the operation characteristics of deep peak regulation(DPR)of TPUs in the coupled system,the constraint of the ladder-type ramping rate applicable for day-ahead dispatch is proposed,and the corresponding flexible spinning reserve constraint is further established.Then,considering these constraints and peak regulation ancillary services,a day-ahead optimal dispatch model of the coupled system is established.Finally,the operational characteristics and advantages of the coupled system are analyzed in several case studies based on a real-world power grid in Liaoning province,China.The numerical results show that the coupled system can further improve the economic benefits of RESs and TPUs under the existing policies.