The components of proton exchange membrane water electrolysers frequently experience corrosion issues, especially at high anodic polarization, that restrict the use of more affordable alternatives to titanium. Here, w...The components of proton exchange membrane water electrolysers frequently experience corrosion issues, especially at high anodic polarization, that restrict the use of more affordable alternatives to titanium. Here, we investigate localized corrosion processes of bare and Ti-coated AISI 446 ferritic stainless steel under anodic polarization by scanning electrochemical microscopy (SECM) in sodium sulphate and potassium chloride solutions. SECM approach curves and area scans measured at open-circuit potential (OCP) of the samples in the feedback mode using a redox mediator evidence a negative feedback effect caused by the surface passive film. For the anodic polarization of the sample, the substrate generation-tip collection mode enables to observe local generation of iron (II) ions, as well as formation of molecular oxygen. For the uncoated AISI 446 sample, localized corrosion is detected in sodium sulphate solution simultaneously with oxygen formation at anodic potentials of 1.0 V vs. Ag/AgCl, whereas significant pitting corrosion is observed even at 0.2 V vs. Ag/AgCl in potassium chloride solution. The Ti-coated AISI 446 sample reveals enhanced corrosion resistance in both test solutions, without any evidence of iron (II) ions generation at anodic potentials of 1.2 V vs. Ag/AgCl, where only oxygen formation is observed.展开更多
基金funding from the EEA Grants 2014-2021,under Project contract No.2/2019 CoDe-PEM(EEA RO-NO-2018-0502).
文摘The components of proton exchange membrane water electrolysers frequently experience corrosion issues, especially at high anodic polarization, that restrict the use of more affordable alternatives to titanium. Here, we investigate localized corrosion processes of bare and Ti-coated AISI 446 ferritic stainless steel under anodic polarization by scanning electrochemical microscopy (SECM) in sodium sulphate and potassium chloride solutions. SECM approach curves and area scans measured at open-circuit potential (OCP) of the samples in the feedback mode using a redox mediator evidence a negative feedback effect caused by the surface passive film. For the anodic polarization of the sample, the substrate generation-tip collection mode enables to observe local generation of iron (II) ions, as well as formation of molecular oxygen. For the uncoated AISI 446 sample, localized corrosion is detected in sodium sulphate solution simultaneously with oxygen formation at anodic potentials of 1.0 V vs. Ag/AgCl, whereas significant pitting corrosion is observed even at 0.2 V vs. Ag/AgCl in potassium chloride solution. The Ti-coated AISI 446 sample reveals enhanced corrosion resistance in both test solutions, without any evidence of iron (II) ions generation at anodic potentials of 1.2 V vs. Ag/AgCl, where only oxygen formation is observed.