Backgroud: The prevention of Legionella spp. colonization of water distribution systems is a critical issue in healthcare settings and only an effective disinfection of water systems and appropriate environmental sur...Backgroud: The prevention of Legionella spp. colonization of water distribution systems is a critical issue in healthcare settings and only an effective disinfection of water systems and appropriate environmental surveillance strategies allow to prevent nosocomial legionellosis. Methods: Due to the temporary effectiveness (increase of the temperature of water in boilers and shock hyperchlorination), the high costs (point-of-use water filters) or the ineffectiveness (hydrogen peroxide, H202) of the previous control procedures, 3 devices (one for each hot water loop) continuously injecting monochloramine have been installed in two different Italian hospitals heavily contaminated by Legionellapneumophila SG3 and SG6. Aim: To evaluate the efficacy of continuous disinfection by monochloramine for control of Legionella on domestic hot water (DHW) distribution system of health-care facilities. Findings: One month after the disinfection of DHW with monochloramine, the load ofL. pneumophila SG3 and SG6 (previous mean count ranging from 103 to 105 CFU/L), as well as the Heterotrophic Plate Count (HPC) (previous mean count ranging from 〉 10^2 to 〉 10^4 CFU/mL), decreased at undetectable levels in 100% of the sampling points in the two hospitals. Conclusion: The results suggest that continuous injection of monochloramine on DHW systems can fully control L. pneumophila and HPC in contaminated hospitals since the beginning of its application.展开更多
文摘Backgroud: The prevention of Legionella spp. colonization of water distribution systems is a critical issue in healthcare settings and only an effective disinfection of water systems and appropriate environmental surveillance strategies allow to prevent nosocomial legionellosis. Methods: Due to the temporary effectiveness (increase of the temperature of water in boilers and shock hyperchlorination), the high costs (point-of-use water filters) or the ineffectiveness (hydrogen peroxide, H202) of the previous control procedures, 3 devices (one for each hot water loop) continuously injecting monochloramine have been installed in two different Italian hospitals heavily contaminated by Legionellapneumophila SG3 and SG6. Aim: To evaluate the efficacy of continuous disinfection by monochloramine for control of Legionella on domestic hot water (DHW) distribution system of health-care facilities. Findings: One month after the disinfection of DHW with monochloramine, the load ofL. pneumophila SG3 and SG6 (previous mean count ranging from 103 to 105 CFU/L), as well as the Heterotrophic Plate Count (HPC) (previous mean count ranging from 〉 10^2 to 〉 10^4 CFU/mL), decreased at undetectable levels in 100% of the sampling points in the two hospitals. Conclusion: The results suggest that continuous injection of monochloramine on DHW systems can fully control L. pneumophila and HPC in contaminated hospitals since the beginning of its application.