FAULT CAUSED BY WATER PRESSURE IN THE HEAD-COVER CHAMBER
1
作者 pei Hai-lin QI Xue-yi +2 位作者 LI Hui LI Jian-hui pei ze-yu 《Journal of Hydrodynamics》 SCIE EI CSCD 2006年第3期280-286,共7页
Owing to the high temperature of the thrust beating pads, the No.l unit wasn't performed in the upgrading test at Liujiaxia Hydropower Plant. Through the experimental and theoretical analysis, it has been confirmed t... Owing to the high temperature of the thrust beating pads, the No.l unit wasn't performed in the upgrading test at Liujiaxia Hydropower Plant. Through the experimental and theoretical analysis, it has been confirmed that the fault unit was caused by the high water pressure in the head-cover chamber. This type of the fault is out-of-the-way. After the suitable measure wags against the fault were taken, the No. 1 unit can stably operate. The conclusions and the methodology are of the certain reference value to the fault-diagnosis of the hydroelectric unit. 展开更多
关键词 hydroelectric unit PERTURBATION vibration fault diagnosis