期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Multi-link Vision and MiniVision stent registry in Asian patients with coronary artery disease:a prospective,multi-center study 被引量:1
1
作者 XU Ya-wei WEI Yi-dong +17 位作者 TANG Kai CHEN Yan-qing LI Wei-ming YU Xue-jing QIN Yong-wen QI Guo-xian QU Peng HOU Yu-qing Ashok Jain parvez grant Gudapati Ramesh Basavappa Ramesh Chumpol Piamsomboon Srun Kuanprasert Hyeon-Cheol Gwon Yoon Haeng Cho Haizal Haroon Kamar HUANG Cong-xin 《Chinese Medical Journal》 SCIE CAS CSCD 2007年第12期1093-1096,共4页
Background Recent studies have showed that the fine mesh stents are associated with a significant reduction in both clinical and angiographic re-stenosis of the coronary arteries. To maintain a very satisfactory radio... Background Recent studies have showed that the fine mesh stents are associated with a significant reduction in both clinical and angiographic re-stenosis of the coronary arteries. To maintain a very satisfactory radio-opacity using the stents, Guidant of the USA has designed a new type of bare metal stents (BMS)-Multi-link (ML) Vision / ML MiniVision stents. The clinical outcomes of Asian patients with coronary artery disease (CAD) after implanting the Multi-link Vision or MiniVision stent were investigated in this study. Methods An observational, prospective, multi-center, non-randomized post marketing registry was conducted to demonstrate the efficacy of the BMS- ML Vision / ML MiniVision stents. The primary end point of the registry was clinical target lesion revascularization (TLR) at a 6-month follow-up. The major secondary end points included the rate of major adverse cardiac events (MACE) and serious adverse events (SAE) in hospital and at 6 months; and the rate of clinical TLR as a function of the type of angina. A total of 429 Asian people with 449 lesions from 14 centers were selected for this study, The average reference diameter of the lesions was (3.0±0.5) mm, and the mean length was (15.7±5.0) mm. Results The successful rate of the procedure was 99.3%. Twenty-five percent of the lesions were treated by direct stenting without pre-dilation. Eighty-six percent of the lesions were implanted with ML Vision stent. After the 6-month follow-up, the rate of clinical TLR was 1.4%. The MACE, SAE and target vessel revascularization (TVR) were 6.8%, 3.5% and 1.4% respectively. Conclusion The current registry showed the excellent 6-month clinical outcomes of ML Vision/ML MiniVision stents in Asian patients with CAD. 展开更多
关键词 bare metal stents registry study Asian population
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部