期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Percutaneous decannulation of extracorporeal membrane oxygenation using MANTA device:A real-world single-center experience
1
作者 Ioannis Milioglou Alice Qian +7 位作者 pedro rafael vieira de oliveira salerno Gabriel Tensol Rodrigues Pereira Luis Augusto Palma Dallan Kelsey E Gray Michael Morrison Yasir Abu-Omar Mohammad Eldiasty Cristian Baeza 《World Journal of Cardiology》 2024年第10期574-579,共6页
BACKGROUND The MANTA vascular closure device(VCD)represents a novel approach to achieving hemostasis after large-bore femoral access procedures.Numerous clinical studies have evaluated the efficacy of the MANTA device... BACKGROUND The MANTA vascular closure device(VCD)represents a novel approach to achieving hemostasis after large-bore femoral access procedures.Numerous clinical studies have evaluated the efficacy of the MANTA device across a range of patient populations undergoing different procedures.However,there is still a paucity of data available concerning the use of MANTA devices in aiding the decannulation of venoarterial extracorporeal membrane oxygenation(VAECMO).AIM To present our single-center experience of utilizing the MANTA VCD in patients undergoing this procedure.METHODS This single-center study included all patients undergoing percutaneous decannulation of femoral VA-ECMO using the MANTA plug-based VCD between January 2021 and October 2023 at University Hospitals Cleveland Medical Center.Inclusion criteria were adult patients who required prolonged(>24 hours)hemodynamic support with VA-ECMO.Outcomes included all-cause mortality,hemostasis,bleeding,limb ischemia,and site infection.RESULTS This is a retrospective cohort study of 19 patients with a mean age of 56.8 years.Twelve of them were males with a mean body mass index of 29.The most common extracorporeal membrane oxygenation indication was acute coronary syndrome complicated by cardiogenic shock at 36.8%.The mean length of intensive care unit stay for these patients was 18.8±8.42 days.Seventeen out of 19 patients survived to discharge.The MANTA device was successfully deployed in 19 patients,with 10 procedures conducted at the bedside and 9 in an operating room setting.Complete hemostasis was achieved within 5 minutes of MANTA deployment in 17 out of 19 patients.In 2 patients manual compression after Manta deployment was required to achieve adequate hemostasis.Additionally,acute lower extremity ischemia was noted in two patients,necessitating endovascular interventions.No infections were reported at the site of MANTA deployment.CONCLUSION Overall,based on our experience and that of other centers,the MANTA VCD has proven to be a simple,safe,and effective percutaneous technique for facilitating in the OR,but most of all it opens the opportunity for bedside VAECMO decannulation.Post-decannulation ischemic complications are higher in this series of sick patients when compared with elective procedures like transcatheter aortic valve replacement and endovascular aneurysm repair.Additionally,operators should be mindful of the incidence of ischemic complications.Distal Doppler pulse signals should always be checked,to indicate bailout options when this occurs. 展开更多
关键词 Extracorporeal membrane oxygenation MANTA Decannulation HEMOSTASIS ISCHEMIA
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部