期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
In vivo optical quality of posterior-chamber phakic implantable collamer lenses with a central port
1
作者 Robert Montés-Micó Francisco Pastor-Pascual +2 位作者 Enrique Artiaga-Elordi Ramón Ruiz-Mesa pedro tañá-rivero 《Eye and Vision》 SCIE CSCD 2023年第5期24-31,共8页
Background: The aim of this review is to summarize the optical quality results in patients following theimplantation of the V4c implantable collamer lens with a central port (ICL, STAAR Surgical Inc.).Main text: A lit... Background: The aim of this review is to summarize the optical quality results in patients following theimplantation of the V4c implantable collamer lens with a central port (ICL, STAAR Surgical Inc.).Main text: A literature search in several databases was carried out to identify those publications, both prospective,retrospective and/or comparative with other refractive surgery procedures, reporting optical outcomes of patientswho were implanted with the V4c ICL model. A total of 17 clinical studies published between 2012 and 2021 wereincluded in this review. A detailed analysis of the available data was performed including number of eyes, follow-upand preoperative spherical equivalent. Specifically, the review focused on several optical parameters includinghigher-order aberrations (HOAs), modulation transfer function (MTF) cut-off frequency and Strehl ratio. This reviewencompassed a total of 817 eyes measured using different optical devices based on Hartmann-Shack, retinal imagequality measurement and ray-tracing technologies at different follow-ups.Conclusions: The outcomes found in this review lead us to conclude that the ICL V4c model provides good opticalquality, by means of different metrics, when implanted. 展开更多
关键词 Implantable collamer lens PHAKIC Optical quality Higher order aberrations Modulation transfer function
原文传递
In vivo optical quality of posterior-chamber phakic implantable collamer lenses with a central port 被引量:4
2
作者 Robert Montés-Micó Francisco Pastor-Pascual +2 位作者 Enrique Artiaga-Elordi Ramón Ruiz-Mesa pedro tañá-rivero 《Eye and Vision》 SCIE CSCD 2021年第1期295-302,共8页
Background:The aim of this review is to summarize the optical quality results in patients following the implantation of the V4c implantable collamer lens with a central port(ICL,STAAR Surgical Inc.).Main text:A litera... Background:The aim of this review is to summarize the optical quality results in patients following the implantation of the V4c implantable collamer lens with a central port(ICL,STAAR Surgical Inc.).Main text:A literature search in several databases was carried out to identify those publications,both prospective,retrospective and/or comparative with other refractive surgery procedures,reporting optical outcomes of patients who were implanted with the V4c ICL model.A total of 17 clinical studies published between 2012 and 2021 were included in this review.A detailed analysis of the available data was performed including number of eyes,follow-up and preoperative spherical equivalent.Specifically,the review focused on several optical parameters including higher-order aberrations(HOAs),modulation transfer function(MTF)cut-off frequency and Strehl ratio.This review encompassed a total of 817 eyes measured using different optical devices based on Hartmann-Shack,retinal image quality measurement and ray-tracing technologies at different follow-ups.Conclusions:The outcomes found in this review lead us to conclude that the ICL V4c model provides good optical quality,by means of different metrics,when implanted. 展开更多
关键词 Implantable collamer lens PHAKIC Optical quality Higher order aberrations Modulation transfer function
原文传递
Angle-to-angle and spur-to-spur distance analysis with high-resolution optical coherence tomography 被引量:2
3
作者 Robert Montés-Micó pedro tañá-rivero +3 位作者 Salvador Aguilar-Córcoles María Ruiz-Santos María Dolores Rodríguez-Carrillo Ramón Ruiz-Mesa 《Eye and Vision》 SCIE CSCD 2020年第1期399-411,共13页
Background:To measure angle-to-angle(ATA)and spur-to-spur(STS)distances along six meridians using highresolution swept-source optical coherence tomography(SS-OCT)and to compare those values with horizontal white-to-wh... Background:To measure angle-to-angle(ATA)and spur-to-spur(STS)distances along six meridians using highresolution swept-source optical coherence tomography(SS-OCT)and to compare those values with horizontal white-to-white(WTW)distance.Methods:68 eyes from 68 patients were quantitatively assessed with the Anterion SS-OCT(Heidelberg Engineering,Heidelberg,Germany).ATA and STS distances were measured with the SS-OCT’s B-Scan in six cross-sectional images corresponding to the vertical(6-12 o’clock),1-7 o’clock,2-8 o’clock,horizontal(3-9 o’clock),4-10 o’clock and 5-11 o’clock meridians.WTW was measured horizontally with the device’s infrared camera.A Pearson correlation analysis was carried out to compare ATA and STS distances with WTW.Results:The largest values were found for the vertical meridian and the shortest for the 2-8 o’clock meridian,both for ATA and STS distances.No statistically significant differences were found between WTW,ATA and STS along the horizontal meridian(p>0.1).However,ATA and STS showed statistically significant differences elsewhere,except for the horizontal and the 2-8 o’clock meridians(p>0.05).Moreover,we found that ATA and STS varied significantly depending on the meridian being assessed,except for ATA at 4-10 versus 3-9 o’clock and for STS at 4-10 versus 3-9 o’clock and at 3-9 versus 2-8 o’clock(p>0.1).R^(2) values ranged from 0.49 to 0.75 for ATA and STS at the different meridians,showing the best correlation at 3-9 o’clock meridian(0.64 and 0.75,respectively)and the worst at 6-12 o’clock meridian(R^(2)=0.49 for both ATA and STS).Conclusions:ATA and STS distances vary radially,thus showing that the anterior chamber is vertically oval.Therefore,it is advisable to measure these two distances along the meridian to be used. 展开更多
关键词 Angle-to-angle Spur-to-spur White-to-white Optical coherence tomography Swept-source Fourier domain
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部