●AIM:To investigate the long-term changes of corneal densitometry(CD)and its contributing elements after small incision lenticule extraction(SMILE).●METHODS:Totally 31 eyes of 31 patients with mean spherical equival...●AIM:To investigate the long-term changes of corneal densitometry(CD)and its contributing elements after small incision lenticule extraction(SMILE).●METHODS:Totally 31 eyes of 31 patients with mean spherical equivalent of-6.46±1.50 D and mean age 28.23±7.38y were enrolled.Full-scale examinations were conducted on all patients preoperatively and during followup.Visual acuity,manifest refraction,axial length,corneal thickness,corneal higher-order aberrations,and CD were evaluated.●RESULTS:All surgeries were completed successfully without complications or adverse events.Ten-year safety index was 1.17±0.20 and efficacy 1.04±0.28.CD value of 0–6 mm zones in central layer was statistically significantly lower 10y postoperatively,compared with preoperative values(0–2 mmΔ=-1.62,2–6 mmΔ=-1.24,P<0.01).There were no correlations between CD values and factors evaluated.●CONCLUSION:SMILE is a safe and efficient procedure for myopia on a long-term basis.CD values get lower 10y postoperatively,whose mechanism is to be further discussed.展开更多
We propose and demonstrate a Raman-assisted passively mode-locked Yb-doped fiber laser in a normal dispersion regime. A section of highly nonlinear fiber is adopted to enhance the nonlinearity to extend the bandwidth ...We propose and demonstrate a Raman-assisted passively mode-locked Yb-doped fiber laser in a normal dispersion regime. A section of highly nonlinear fiber is adopted to enhance the nonlinearity to extend the bandwidth of the gain spectrum by the stimulated Raman effect. The mode-locked fiber laser emits a broad spectral bandwidth of 64 nm at the-20 dB level and a highly stable pulse operation with a signal-to-noise ratio of 77 dB.展开更多
Dear Editor,We present the reported case of the aqueous humour flow observed in vivo after implantable collamer lens(ICL)with a central hole implantation surgery.ICL,a phakic intraocular lens which is located in the p...Dear Editor,We present the reported case of the aqueous humour flow observed in vivo after implantable collamer lens(ICL)with a central hole implantation surgery.ICL,a phakic intraocular lens which is located in the posterior chamber,is an effective treatment to correct moderate-tohigh myopia^([1-2]).展开更多
文摘●AIM:To investigate the long-term changes of corneal densitometry(CD)and its contributing elements after small incision lenticule extraction(SMILE).●METHODS:Totally 31 eyes of 31 patients with mean spherical equivalent of-6.46±1.50 D and mean age 28.23±7.38y were enrolled.Full-scale examinations were conducted on all patients preoperatively and during followup.Visual acuity,manifest refraction,axial length,corneal thickness,corneal higher-order aberrations,and CD were evaluated.●RESULTS:All surgeries were completed successfully without complications or adverse events.Ten-year safety index was 1.17±0.20 and efficacy 1.04±0.28.CD value of 0–6 mm zones in central layer was statistically significantly lower 10y postoperatively,compared with preoperative values(0–2 mmΔ=-1.62,2–6 mmΔ=-1.24,P<0.01).There were no correlations between CD values and factors evaluated.●CONCLUSION:SMILE is a safe and efficient procedure for myopia on a long-term basis.CD values get lower 10y postoperatively,whose mechanism is to be further discussed.
基金Supported by the National Natural Science Foundation of China under Grant No 61675188and the Open Fund of Key Laboratory Pulse Power Laser Technology of China under Grant No SKL2016KF03
文摘We propose and demonstrate a Raman-assisted passively mode-locked Yb-doped fiber laser in a normal dispersion regime. A section of highly nonlinear fiber is adopted to enhance the nonlinearity to extend the bandwidth of the gain spectrum by the stimulated Raman effect. The mode-locked fiber laser emits a broad spectral bandwidth of 64 nm at the-20 dB level and a highly stable pulse operation with a signal-to-noise ratio of 77 dB.
基金Supported by National Natural Science Foundation of China(No.81500753,No.81570879)Project of Shanghai Science and Technology(No.17140902900,No.17411950200)。
文摘Dear Editor,We present the reported case of the aqueous humour flow observed in vivo after implantable collamer lens(ICL)with a central hole implantation surgery.ICL,a phakic intraocular lens which is located in the posterior chamber,is an effective treatment to correct moderate-tohigh myopia^([1-2]).
基金This work was supported by the Na- tional Key Basic Research Program of China under Grant No. 2012CB922003, and the National Natural Science Foundation of China (NSFC) under Grant No. 61177053, and Anhui Provincial Natural Science Foundation under Grant No. 1508085SMA205.