Sharp local structure, like the leading edge of hypersonic aircraft, confronts a severe aerodynamic heating environment at a Mach number greater than 5. To eliminate the danger of a material failure, a semi-active the...Sharp local structure, like the leading edge of hypersonic aircraft, confronts a severe aerodynamic heating environment at a Mach number greater than 5. To eliminate the danger of a material failure, a semi-active thermal protection system is proposed by integrating a metallic heat pipe into the structure of the leading edge. An analytical heat-balance model is established from traditional aerodynamic theories, and then thermal and mechanical characteristics of the structure are studied at Mach number 6–8 for three refractory alloys, Inconel 625, C-103, and T-111. The feasibility of this simple analytical method as an initial design tool for hypersonic aircraft is assessed through numerical simulations using a finite element method. The results indicate that both the isothermal and the maximum temperatures fall but the von Mises stress increases with a longer design length of the leading edge. These two temperatures and the stress rise remarkably at a higher Mach number. Under all investigated hypersonic conditions, with a 3 mm leading edge radius and a0.15 m design length, the maximum stress exceeds the yield strength of Inconel 625 at Mach numbers greater than 6, which means a material failure. Moreover, both C-103 and T-111 meet all requirements at Mach number 6–8.展开更多
基金financially supported by the Foundation for Innovative Research Groups of the National Natural Science Foundation of China(No.51121004)the Fundamental Research Funds for the Central Universities(No.HIT.BRETIV.201315)
文摘Sharp local structure, like the leading edge of hypersonic aircraft, confronts a severe aerodynamic heating environment at a Mach number greater than 5. To eliminate the danger of a material failure, a semi-active thermal protection system is proposed by integrating a metallic heat pipe into the structure of the leading edge. An analytical heat-balance model is established from traditional aerodynamic theories, and then thermal and mechanical characteristics of the structure are studied at Mach number 6–8 for three refractory alloys, Inconel 625, C-103, and T-111. The feasibility of this simple analytical method as an initial design tool for hypersonic aircraft is assessed through numerical simulations using a finite element method. The results indicate that both the isothermal and the maximum temperatures fall but the von Mises stress increases with a longer design length of the leading edge. These two temperatures and the stress rise remarkably at a higher Mach number. Under all investigated hypersonic conditions, with a 3 mm leading edge radius and a0.15 m design length, the maximum stress exceeds the yield strength of Inconel 625 at Mach numbers greater than 6, which means a material failure. Moreover, both C-103 and T-111 meet all requirements at Mach number 6–8.